![otometrics madsen itera ii Скачать руководство пользователя страница 7](http://html.mh-extra.com/html/otometrics/madsen-itera-ii/madsen-itera-ii_reference-manual_1658678007.webp)
1
Introduction to MADSEN Itera II
MADSEN Itera II is an audiometer for testing a person's hearing.
With MADSEN Itera II you can perform all standard audiometric tests, tone and speech
audiometry and special tests.
Depending on the configuration, various special tests such as SISI, Stenger, ABLB (Fowler),
and HIS are available.
•
MADSEN Itera II can be used in connection with the OTOsuite Audiometry Module software for online monitoring
of test results, data export and storage, printing, and NOAH compatibility.
•
MADSEN Itera II can be used as a portable instrument or as a desktop unit (fixed installation).
Operation
The front panel buttons have indicator lights, which clearly show the device's current settings.
Sound level, frequency and other information are shown clearly on the device display.
Speech input signals can be taken from a CD player, tape recorder and internal or external microphones. The masking sig-
nal for speech audiometry can be presented together with the speech signal for the ear being examined - "Speech in
Noise".
Output options
There are three output options:
•
standard headphones (AC),
•
bone conductors (BC)
•
special output (SF), which can be connected for instance to a free-field loudspeaker or insert phone (see available out-
put in
).
MADSEN Itera II can be calibrated for several types of headphones simultaneously.
Transferring data to and from a pc
The test results are stored in the device - even when it is switched off. The results can be transferred to a PC and displayed
in OTOsuite (see
).
You can download new firmware to MADSEN Itera II, and if this involves no change to the transducers, MADSEN Itera II
does not need to be recalibrated.
1.1
The Audiometry Module
OTOsuite
OTOsuite is a software tool that integrates a suite of audiological tests with result review
and reporting capabilities into a single powerful PC application.
The OTOsuite Audiometry Module is designed to operate with MADSEN Itera II as the test device.
The OTOsuite Audiometry Module
The OTOsuite Audiometry Module provides you with comprehensive control and overview of the current stimulus and
masking choices both numerically and graphically in the displayed audiogram when you test with a connected Otometrics
audiometer.
Otometrics - MADSEN Itera II
7
Содержание madsen itera ii
Страница 1: ...MADSEN Itera II Reference Manual Doc No 7 50 0860 EN 26 Part No 7 50 08600 EN ...
Страница 10: ...1 Introduction to MADSEN Itera II 10 Otometrics MADSEN Itera II ...
Страница 52: ...4 Navigating in the OTOsuiteAudiometry Module 52 Otometrics MADSEN Itera II ...
Страница 60: ...5 Preparing for testing 60 Otometrics MADSEN Itera II ...
Страница 68: ...6 Tone testing 68 Otometrics MADSEN Itera II ...
Страница 74: ...7 Speech testing 74 Otometrics MADSEN Itera II ...
Страница 86: ...9 Managing Data and Results 86 Otometrics MADSEN Itera II ...
Страница 110: ...15 Maximum non destructive voltage 110 Otometrics MADSEN Itera II ...
Страница 118: ...18 Standards and safety 118 Otometrics MADSEN Itera II ...