OI-7543 SENSOR 
ASSEMBLY

Содержание OI-7543

Страница 1: ...OI 7543 SENSOR ASSEMBLY...

Страница 2: ...2 GETTING TO KNOW THE PRODUCT...

Страница 3: ...y Voltage 12 35 VDC or 120 240 Volts AC Temperature 30 C to 70 C Channels 4 channels with individually configurable set points Relays Three dry contact 5 Amp w 4 Amp fuses Radio Options 2 4 GHz 900 MH...

Страница 4: ...Learning the Product Parts Complete System 4...

Страница 5: ...Learning the Product Parts Control Board 5...

Страница 6: ...6 BASIC OPERATION GUIDELINES...

Страница 7: ...allowed 1 The OI 7543 will automatically Power On when the Power Wiring Configurations are complete and voltage is supplied to the unit 2 The device will then count down from 10 to 0 Power On From 10...

Страница 8: ...perating Mode the display screen should resemble the following illustration Power On NOTE If a channel is in Fault the display screen will show F NOTE If the relays for a channel are active the displa...

Страница 9: ...adio signals from the sensors The OI 7543 power is controlled by either an AC or DC power source the OI 7543 will automatically Power Off when voltage is no longer supplied to the unit by either turni...

Страница 10: ...10 BASIC CONFIGURATION MENU...

Страница 11: ...lly for each sensor Therefore Individual Channel Setup must be completed the same number of times that there are sensors being monitored NOTE To exit the Basic Configuration Menu at any time touch ADD...

Страница 12: ...d MENU for five seconds 3 The display screen should resemble this illustration 4 Touch ADD increase or SUB decrease to manipulate the Channel Selection setting 1 4 5 Once the channel has been selected...

Страница 13: ...once 2 The display screen should resemble this illustration right 3 Touch ON ADD or OFF SUB to manipulate the Channel On Off setting 4 If the channel is set to On proceed to the next step If the chann...

Страница 14: ...previous section touch MENU once 2 The display screen should resemble this illustration right 3 Touch ADD increase or SUB decrease to manipulate the Radio Address 4 Once the Address is set proceed to...

Страница 15: ...Touch ON ADD or OFF SUB to manipulate the Relay On Off setting 4 If the relay is set to On proceed to the next step If the relay is set to Off proceed to setting the next relays to On Off When settin...

Страница 16: ...vious section touch MENU once 2 The display screen should resemble this illustration right 3 Touch RISE ADD or FALL SUB to manipulate the setting type of the relay 4 Once the Relay Setting Type is set...

Страница 17: ...revious section touch MENU once 2 The display screen should resemble this illustration right 3 Touch ADD increase or SUB decrease to manipulate the Relay Value Setting 4 Once the Relay Value Setting i...

Страница 18: ...touch MENU once 2 The display screen should resemble this illustration right 3 Touch ADD increase or SUB decrease to manipulate the Relay Latching Unlatching Setting 4 Once Relay is set to latching o...

Страница 19: ...19 RELAY SETUP MUST BE COMPLETED INDIVIDUALLY FOR EACH RELAY REPEAT THE RELAY SETUP STEPS THE PREVIOUS FOUR SECTIONS FOR EACH OF THE THREE RELAYS ONCE ALL THREE RELAYS HAVE BEEN SETUP CONTINUE TO THE...

Страница 20: ...ld resemble the following illustration Duplicate Channel 3 Press YES ADD to duplicate the channel Press MENU to decline the duplication option and proceed to setup the next channel NOTE To exit the Ba...

Страница 21: ...CHANNEL SETUP 21 CHANNEL SETUP MUST BE COMPLETED INDIVIDUALLY FOR EACH CHANNEL REPEAT THE CHANNEL SETUP INSTRUCTIONS FOR EACH CHANNEL BEFORE USE...

Страница 22: ...22 ADVANCED CONFIGURATION MENU Global Settings...

Страница 23: ...rning off the voltage supply at the power source DC power or by unplugging the unit AC power Power on the device by supplying voltage to the unit 2 Open the enclosure box 3 When the Otis Logo is shown...

Страница 24: ...24 Touch ADD increase or SUB decrease to manipulate the LCD contrast Touch MENU Next to confirm the setting Adjusting LCD Contrast...

Страница 25: ...he factory s default settings Touch MENU Next to confirm the settings Factory settings are Restore Factory Default Settings Channels 1 4 On All Relays set On at 10 15 20 Unlatching Rising Channel Addr...

Страница 26: ...No as indicated on the display screen to setup Relay 3 as the Fault Relay Touch MENU Next to confirm the setting NOTE With this feature enabled if any Fault occurs on any channel the Fault Relay is e...

Страница 27: ...if Yes is chosen on the previous option setting Relay 3 as a Fault Relay If No is chosen on the previous option continue to the next step Touch ADD or SUB Yes No as indicated on the display screen to...

Страница 28: ...28 Relay Failsafe Setup Relay 1 Failsafe Touch ADD or SUB Yes No as indicated on the display screen to set the Relay 1 Failsafe Setting Press MENU Next to confirm the setting...

Страница 29: ...29 Relay Failsafe Setup Relay 2 Failsafe Touch ADD or SUB Yes No as indicated on the display screen to set the Relay 2 Failsafe Setting Press MENU Next to confirm the setting...

Страница 30: ...30 Relay Failsafe Setup Relay 3 Failsafe Touch ADD or SUB Yes No as indicated on the display screen to set the Relay 3 Failsafe Setting Press MENU Next to confirm the setting...

Страница 31: ...31 Relay Failsafe Setup Fault Terminal Failsafe Touch ADD or SUB Yes No as indicated on the display screen to set the Fault Terminal Failsafe Setting Press MENU Next to confirm the setting...

Страница 32: ...32 Radio Timeout Setting Press ADD increase or SUB decrease to manipulate the Radio Timeout Setting Press MENU Next to confirm the setting...

Страница 33: ...33 Network Channel Setting Touch ADD increase or SUB decrease to manipulate the Network Channel Setting Press MENU Next to confirm the setting...

Страница 34: ...ENU Next to confirm the setting and exit the Advanced Configuration Menu NOTE On each Gen II network there can be only one Primary monitor all other monitors must be setup as Secondary monitors NOTE I...

Страница 35: ...ble to notify the user of gas presence at the sensor with a low high or danger alarm To ensure that each of these features are working properly the following tests should be run periodically If a test...

Страница 36: ...d MENU and SUB for five seconds to enter Alarm Test Mode 2 To pass the Low Alarm Test the device must do the following LED 1 will illuminate Any connected alarm will trigger 3 If the system passes the...

Страница 37: ...the magnets to MENU and SUB for an additional five seconds 2 To pass the High Alarm Test the device must do the following LED 2 will illuminate Any connected alarm will trigger 3 If the system passes...

Страница 38: ...additional five seconds 2 To pass the Danger Alarm Test the device must do the following LED 3 will illuminate Any connected alarm will trigger 3 Once the Danger Alarm Test is complete release the mag...

Страница 39: ...a that is compatible with the radio frequency and antenna fitting on the enclosure 1 Power off the device by turning off the voltage supply at the power source DC power or by unplugging the unit AC po...

Страница 40: ...40 WIRING CONFIGURATIONS Power Supply...

Страница 41: ...hipped from Otis Instruments Inc NOTE To ensure technician safety always wire the relays BEFORE supplying power to the device 1 Open the Enclosure Box 2 Unscrew the two Thumbscrews 3 Open the Front Pa...

Страница 42: ...he terminal labeled GND on the Terminal Board s 12 to 35VDC Terminal Block 9 Connect the other end of that same negative wire black from the Terminal Board to the terminal labeled V on the internal De...

Страница 43: ...anel 4 Using the handles on the Front Panel lift the Front Panel completely out of the Adalet enclosure to expose the terminals on the back side of the Terminal Board 5 Locate the Relay 1 terminal blo...

Страница 44: ...inal Block 7 Connect the positive wire red from the Low Alarm to the terminal labeled NO or NC on the Relay 1 Terminal Block 8 Connect the neutral wire black from the Low Alarm to the terminal labeled...

Страница 45: ...oard 2 Bring the two conductor cables from the High Alarm to the OI 7543 using the proper certified 3 4 NPT cable gland or conduit fitting 3 Run the two conductor cables for Relay 2 from the High Alar...

Страница 46: ...d from the High Alarm to the terminal labeled NO on the Relay 2 Terminal Block 6 Connect the neutral wire black from the High Alarm to the terminal labeled V on the internal Delta Power Supply 7 Once...

Страница 47: ...ard 2 Bring the two conductor cables from the Danger Alarm to the OI 7530 using the proper certified 3 4 NPT cable gland or conduit fitting 3 Run the two conductor cables for Relay 3 from the Danger A...

Страница 48: ...Terminal Block 6 Connect the neutral wire black from the Danger Alarm to the terminal labeled V on the internal Delta Power Supply 7 Close the Front Panel 8 Screw in the Thumbscrews 9 Close the Enclos...

Страница 49: ...by the purchaser when shipped from Otis Instruments Inc NOTE To ensure technician safety always wire the relays BEFORE supplying power to the device 1 Open the Enclosure Box 2 Unscrew the two Thumbscr...

Страница 50: ...nal Board s 12 to 35VDC Terminal Block 5 Connect the other end of the same positive wire red to a DC Power Supply 6 Connect a negative wire black to the terminal labeled GND on the Terminal Board s 12...

Страница 51: ...beled COM on the Relay 1 Terminal Block 3 Connect the positive wire red from the Low Alarm to the terminal labeled NO or NC on the Relay 1 Terminal Block 4 Connect the neutral wire black from the Low...

Страница 52: ...jumper wire blue from the terminal labeled COM on the Relay 1 Terminal Block to the terminal labeled COM on the Relay 2 Terminal Block 3 Connect the positive wire red from the High Alarm to the termin...

Страница 53: ...lock to the terminal labeled COM on the Relay 3 Terminal Block 3 Connect the positive wire red from the Danger Alarm to the terminal labeled NO or NC on the Relay 3 Terminal Block 4 Connect the neutra...

Страница 54: ...Terminal Block 6 Connect the neutral wire black from the Danger Alarm to the terminal labeled V on the internal Delta Power Supply 7 Close the Front Panel 8 Screw in the Thumbscrews 9 Close the Enclos...

Страница 55: ...55 TROUBLESHOOTING GUIDE...

Страница 56: ...ard Check the orientation of the analog sensor board and or try a new analog sensor board On the OI 6900 X and OI 6975 X units F4 means the top card is not communicating with the analog sensor board C...

Страница 57: ...Check all units and make sure they are all using a different addresses F9 Radio timeout This means the monitor has not gotten a communication from the faulting address for over X minutes X is equal to...