background image

 

 

 

All Digital Fiber Optic Manufacturing Specialists 

 

 

Installation and Operation Manual 

 

FT810DB Series 

 

 

 
10-bit Digital Series   

8-ch Video with 1 Bi-directional Data   
Fiber Optic Converter

 

 

 

 

 

 

OT Systems Ltd., 2009   

Rev 1.1 

Содержание FT810DB Series

Страница 1: ... Digital Fiber Optic Manufacturing Specialists Installation and Operation Manual FT810DB Series 10 bit Digital Series 8 ch Video with 1 Bi directional Data Fiber Optic Converter OT Systems Ltd 2009 Rev 1 1 ...

Страница 2: ...eivers FT810DB SSRSA FT810DB SSRLSA Multi Mode Transmitter FT810DB SMTSA Multi Mode Receiver FT810DB SMRSA Card Modules Single Mode Transmitters FT810DB SST FT810DB SSTL Single Mode Receivers FT810DB SSR FT810DB SSRL Multi Mode Transmitter FT810DB SMT Multi Mode Receiver FT810DB SMR Remark If the optical connector is FC type the suffix in the model number will be FXX Eg FT810DB FST ...

Страница 3: ...Standalone unit installation 6 3 3 Card module installation 7 4 CABLE CONNECTIONS SETUP PROCEDURES 7 4 1 System cable connections 7 4 2 Data port assignment and pin connections 9 4 3 Dip switch setting procedures 10 4 4 Ground connection 12 5 OPERATIONAL GUIDES 12 5 1 FT810DB Series Transmitter 12 5 2 FT810DB Series Receiver 13 6 SPECIFICATIONS 14 7 DRAWINGS 15 8 WARRANTY INFORMATION 15 9 CONTACT ...

Страница 4: ...o Class I invisible optical radiation is possible when the internal fiber optic connector is disconnected while the unit is powered up Caution Any access to the controls adjustments or performing operations which are other than those specified may result in hazardous radiation exposure Permanent eye damage or other bodily injuries may be resulted from such exposure even for only seconds Note 2 Thi...

Страница 5: ...x TDM technology is employed for digital transmission of forward video and data whereas optical Wavelength Division Multiplex WDM technology is employed for simultaneous reverse data transmission as well as bi directional data transmission For single mode transmission we also offer specifically designed products for long haul transmissions up to 60km These models include the letter L in the suffix...

Страница 6: ...ansmitter 1 Data Transceiver Standalone Unit FT810DB SMRSA Multi mode 8 Ch Video Receiver 1 Data Transceiver Standalone Unit Card Modules Single Mode FT810DB SST Single mode 8 Ch Video Transmitter 1 Data Transceiver Card Module Housed in FT C18 chassis 3 FT C18 chassis has to be ordered separately FT810DB SSTL Single mode Long haul 8 Ch Video Transmitter 1 Data Transceiver Card Module FT810DB SSR ...

Страница 7: ...an be housed inside the chassis 3 2 Standalone unit installation a Mount the standalone unit onto a fixture either on the wall or on a flat surface with four screws through the holes on the mounting frame to secure it in position b The provided power supply should also be mounted on the same fixture or in the proximity for connection of the supply cables to the unit provided that an AC power suppl...

Страница 8: ... front and back panels of the card modules are lit If not check the power supply cable connections between the chassis and the power supply socket For failures of individual card s POWER LEDs check the corresponding card modules whether they have been inserted properly e With all the signals available at the input and output ports check the status of LEDs located on the unit With correct status of...

Страница 9: ...ation Manual www ot systems com 8 Standalone Transmitter Card Module Receiver Fig 4 2 Standalone unit to Card Module connection diagram Card Module Transmitter Card Module Receiver Fig 4 3 Card Module to Card Module connection diagram ...

Страница 10: ...agram Transmitter End Receiver End User s Equipment DATA PORT 7 PIN DATA PORT 7 PIN User s Equipment TX 1 IN 1 IN TX TX 2 IN 2 IN TX RX 3 OUT 3 OUT RX RX 4 OUT 4 OUT RX 5 N A 5 N A 6 N A 6 N A 7 N A 7 N A Fig 4 4 1 Connector Pin Assignments for 4 wire RS422 485 data format at Data port 2 Wire RS485 Half Duplex Data communication connection diagram Transmitter End Receiver End User s Equipment DATA...

Страница 11: ...T 6 OUT RX Sig COM 7 Sig COM 7 Sig COM Sig COM Fig 4 4 3 Connector Pin Assignments for RS232 data format at Data port 4 3 Dip switch setting procedures The only setup procedure is to select the appropriate line terminations and data transmission formats Selections must be made by setting the dip switches Fig 4 5 through the access on the front panel a Dip switches on FT810DB Series Standalone unit...

Страница 12: ... input and output lines terminated in the ONE Tx to ONE Rx configuration For RS485 2 4 wire communication the RS485 device can be disabled to stay in a Hi Z state It is very important that the data lines have to be terminated with a resistor being connected across the pair wires so as to eliminate the residual standing signal waves on the lines in the Hi Z line condition So it is recommended that ...

Страница 13: ...good ground connections to the buildings ground in accordance with the local codes Fig 4 7 Standalone unit earth terminal location 5 Operational Guides 5 1 FT810DB Series Transmitter LED Indicators Indicator Color Description PWR Red Lit when power is supplied to the Transmitter OL Yellow Lit when optical signal from receiver to transmitter is active VIDEO IN VIN V1 Green Lit when video signals ar...

Страница 14: ...er is supplied to the Receiver OL Yellow Lit when optical signal from transmitter to receiver is active VIDEO OUT VOUT V1 Green Lit when video signals are received at VIDEO OUT connectors V2 Green V3 Green V4 Green V5 Green V6 Green V7 Green V8 Green DATA IN Red Blinks when input data is available at Rx OUT Green Blinks when output data is available at Rx Signal Ports OPT ST or FC Optical Connecto...

Страница 15: ...al Gain 1 typical Differential Phase 1o typical SNR 65dB DATA Channel Connector 1 7 pin Screw Terminal Direction Bi directional Duplex Electrical Format RS232 RS422 RS485 2 wire 4 wire Tri state Transmission Rate 0 256Kbps POWER Power consumption 12VDC 6 6W Power Supply Standalone Unit FT PA12V DC Adaptor Card module Powered by FT C18 chassis Connector Standalone unit 2 pin Screw Terminal PHYSICAL...

Страница 16: ... refer to the OT Systems Products Warranty Statement for details Access to the statement is available in our company website at www ot systems com 9 Contact Information OT Systems Ltd Hong Kong Unit 1023 10 F Landmark North 39 Lung Sum Avenue Sheung Shui N T Hong Kong Tel 852 2672 5153 Fax 852 2679 0756 sales ot systems com OT Systems Ltd USA River Heights Business Park 5375 US Highway 34 Oswego I...

Отзывы: