background image

           

 

ET8122MPH-S-DR   

Hardened 8-port 10/100TX + 2-Port 10/100/1000T/100/1000 SFP Combo with 8 PoE Injectors 
Industrial Ethernet Switch 

 

This quick start guide describes how to install and use the hardened Ethernet Switch. Capable of operating at temperature extremes of -40°C to 

+75°C, this is the switch of choice for harsh environments constrained by space. 

 

Physical Description 

The Terminal Block and Power inputs 

 

 

The Terminal Block 

PWR1 

Power Input 1 (48VDC) 

GND 

Power Ground 

PWR2 

Power Input 2 (48VDC) 

GND 

Power Ground 

 

Earth Ground 

 

FAULT 

The relay opens if PWR1 or PWR2 fails (1A) 

DC Terminal Block Power Inputs: There are two pairs of power inputs can be used to power up this media converter. Redundant power supplies 

function is supported. You only need to have one power input connected to run the Switch. 

 

The 10/100Base-TX and Mini-GBIC combo port 

The 10/100Base-TX Connections 

The following lists the pinouts of 10/100Base-TX ports. 

 

Pin 

Regular Ports 

Uplink port 

Output Transmit Data + 

Input Receive Data + 

Output Transmit Data - 

Input Receive Data - 

Input Receive Data + 

Output Transmit Data + 

NC 

NC 

NC 

NC 

Input Receive Data - 

Output Transmit Data - 

NC 

NC 

NC 

NC 

 

 

Содержание ET8122MPH-S-DR

Страница 1: ...r Input 2 48VDC GND Power Ground Earth Ground FAULT The relay opens if PWR1 or PWR2 fails 1A DC Terminal Block Power Inputs There are two pairs of power inputs can be used to power up this media conve...

Страница 2: ...speeds of 10 100 1000Mbps that support auto sensing technology to enable each port to detect the connecting speed The mini GBIC port is a joint for a mini GBIC SFP transceiver so the switch can be up...

Страница 3: ...32 connector and the other end is RJ 45 connector Attach the end of RS 232 connector to PC or terminal and the other end of RJ 45 connector to the console port of the switch The connected terminal or...

Страница 4: ...s to match the following default characteristics of the console port Baud Rate 9600 bps Data Bits 8 Parity none Stop Bit 1 Flow control None The settings of communication parameters Having finished th...

Страница 5: ...ndustrial switch is the master of X Ring group Off The industrial switch is not a ring master in X Ring group PWR1 Green On Power 1 is active Off Power 1 is inactive PWR2 Green On Power 2 is active Of...

Страница 6: ...from the TX device Off No device attached Amber On The port is operating in full duplex mode Blinking Collision of Packets occurs Off The port is in half duplex mode or no device is attached FWD P1 P8...

Страница 7: ...actory If the DIN Rail is not screwed on the industrial switch please see the following pictures to screw the DIN Rail on the switch Follow the steps below to hang the industrial switch 1 First insert...

Страница 8: ...with wall mount plate 1 Remove the DIN Rail from the industrial switch loose the screws to remove the DIN Rail 2 Place the wall mount plate on the rear panel of the industrial switch 3 Use the screws...

Страница 9: ...ssembly Startup and Dismantling Wall Mounting Kit installation Assembly Securely fasten the wall mount kits to the bottom of module by using the provided screws 6 pcs Mount the standalone unit onto a...

Отзывы: