Osram TW-DL-12V/110mA-Power Pack Скачать руководство пользователя страница 1

www.osram.us/ds

Installation Instruction

TW-DL-12V/110mA-Power Pack

 

P/N: 58290 — 110mA output max. — 12V

dc

 nominal 

For use with OSRAM Tunable White Wallstation (58289) 

Important Safeguards 

!

When using electrical equipment, basic safety precautions should 
always be followed including the following:

 

To avoid fire, shock, or death, turn off power 

at circuit breaker or fuse 

and test

      

that power is off before wiring, servicing fixture or changing lamps.

 To be installed and/or used in accordance with appropriate electrical codes and 

regulations.

 If you are not sure about any part of these instructions, consult an electrician.

 This device can be wired either as a Class 1 or Class 2 wiring device. Be sure to 

install in the same manner as the other devices on the DALI loop. When in doubt, 
install as a Class 1 wiring device. Consult local building codes and regulations for 
proper low-voltage installation.

!

Save These Instructions

Features

 

A maximum of 2 Power Packs can be added in parallel as long 
as the total current supply on a single loop is below 250mA

 

Control wiring can be Class 1 or Class 2 installed

 

Polarity-independent control wiring

 

Flexible 2-wire DALI

®

 loop control wiring – daisy chain, 

point to point, star or mix method

Specifications

 

Input Voltage:

 120/277V

ac

 ± 10%

 

DALI Output Voltage:

 12V

dc

 nominal

 

 

DALI Output Current:

 110mA

 

 

Approved for Class I or II control wiring

Description

The OSRAM TW-DL-12V/110mA-Power Pack provides power to a DALI network. A single power pack can provide 110mA of power, which would be used by a combina-
tion of DALI compatible controllers and ballasts. 

Please refer to LMS168 for details on how many wallstations/LED Drivers can be powered with this power pack. 

If more current is required, one other OSRAM power pack can be added in parallel to a single DALI network, which would bring the total current supply to 220mA.
Please note that the total current supply on a DALI loop cannot exceed 250mA. The power pack is mounted directly to a junction box 

(refer to Figure 1)

. The unit must 

be installed in a properly grounded metal 4" (10.16 cm) outlet box, a minimum of 2 1/8" (5.39 cm) deep. All Class 2 (low-voltage) wiring must be contained within the 
Class 2 compartment (the area enclosed by the isolation barrier –

refer to Figure 2

). All Class 1 (high-voltage) wiring must be contained within the Class 1 compartment 

(refer to Figure 2)

. Install or rearrange circuit wiring so all high-voltage circuit and load wires enter the box from one side, and all low-voltage wires enter from the other.

Figure 1

Figure 2

OSRAM P/N:
58290

4" square
elecrical box

4.10" (104.1mm)

4.10

" (104.1mm)

1.63

"

 (41.4mm)

THIS

COMPARTMENT

FOR CLASS  TWO

WIRING ONL Y

Low voltage leads

Low voltage

compartment 

cover

Insulation barrier

High voltage 

leads

Light is OSRAM

Отзывы: