USER MANUAL FOR THE OSMIO INFINITY HYDROXY GAS/WATER PRODUCTION ELECTROLYSIS SYSTEM
18
When attaching the tubes do not push the tubes too far, only push on tight
enough to seal. You should only have to rock & twist the tube gently to
remove it. The tower cap should only be removed when necessary and not
overtightened.
3.6
Performing the Operational Check
Before using the system for the first time, take time to perform the following
operational check
●
Ensure the system is plugged in and switched ON
●
Check that the red internal light is on (can be seen at the back of the system)
●
Check that the blue sight tube illumination light is on
●
Check that the fluid level is between 80% and 100%.
●
Frequency is preset to 432 Hertz
●
Ensure duty cycle is set to correct level for the individual using the system (see
section 3.8)
●
Turn on the timer (please see section 3.7 to avoid damage)
●
●
Check gas is bubbling in both humidifiers
3.7
System Settings
The system has a feature that allows you to set the Frequency being pulsed to the
electrolyser. Frequency is usually referred to in AC as Hertz (Hz) or in the case of DC
as pulses per second (pps).
The system comes preset to 432 Hz with a duty cycle of 50% (see section 3.6 to
calculate the duty cycle). The Frequency (FREQ) buttons control how many pulses per
second are sent to the electrolyser. The power pulses DC electricity to the
electrolyser 432 times per second (preset) and this can be varied if another frequency
is required.
The system can have a mechanical or digital timer switch to control gas production.
Please see sections 3.8 & 3.9 for instructions.