Installation Quick Guide 

 

 
Rapiscan Systems Proprietary Information 

IMPORTANT INSTRUCTIONS 

 
 

 

Read through this chapter carefully before operating the equipment. Keep this manual 
so that it is always readily available to the user. 
 
The instructions in this manual shall be followed in all situations, when installing, 
using, or servicing the equipment. Rapiscan Systems cannot be held responsible for 
any personal or material damage caused by use contradicting the instructions given in 
this manual. 
 
All safety regulations must be observed. A dangerous or unsafe manner of operation 
may be a health risk. 
 
Installation may only be carried out by qualified person. 
 
Before installing, operating or servicing the equipment, make sure that it poses no risk 
of personal or material damage. 
 
Be aware that although the walk through metal detector unit is heavy it may fall down if 
a heavy force collides with it. To eliminate the risk of overbalancing the WTMD must be 
attached (anchored) on the floor. 
 
Do not operate the equipment unless you are fully trained to do so. The operator must 
know the use, service, and safety instructions of the equipment, and local safety 
regulations. 
 
Service of Rapiscan products shall be preformed only by a Rapiscan Systems qualified 
service provider or authorized contractor qualified service provider. Make sure that 
there are no unauthorized persons in the working area when servicing and repairing 
the equipment. 
 
It is forbidden to operate the equipment when ill, or under the influence of alcohol or 
drugs. 
 
The equipment may not be connected to mains supply until all other connections 
necessary for the installation are completed. 
 
The equipment shall always be connected to an earthed socket outlet. 
 
The equipment shall be disconnected from mains supply before servicing, cleaning, or 
moving it. 
 
Original Metor spare parts should be exclusively used. 
 
Use a damp cloth for cleaning the equipment. Do not use any chemicals or liquid 
detergents. 
 
The end user is responsible for the final calibration of the equipment for the intended 
application. It is also the end user’s responsibility to regularly verify calibration to the 
desired sensitivity level by using a suitable test object or objects. 
 
If there is any reason to suspect that the security level of the equipment may have 
deteriorated due to incorrect operation or external damage, the equipment should be 
removed from operation and an authorized service provider should be called in. 

Содержание Rapiscan Metor 6E

Страница 1: ...Rapiscan Systems 1 1 Printing instructions_A4 doc DO NOT PRINT THIS PAGE PRINT FOLLOWING DOCUMENT AS 2 SIDED COLOR PRINTING FORMAT A5 ON A4 BOOKLET FOLD AND STAPLE AT CENTER DO NOT PRINT THIS PAGE...

Страница 2: ...Installation Quick Guide Metor 6E P N 92109435 Rev 2...

Страница 3: ...f you have any questions about the content of this manual or the product that you have purchased please contact Rapiscan Systems Customer Service No Warranties The provision of this manual to you crea...

Страница 4: ...ry Information Revision History Name of Document Installation Quick Guide Metor 6E Document Number 92109435 Revision 2 Rev ECN Date Name Comments A 2013 05 20 TV Initial draft B 2013 06 06 TV Several...

Страница 5: ...ert Messages 6 1 2 Symbols used on Unit and in Manual 6 2 TECHNICAL DATA 7 3 INSTALLATION 8 3 1 Mechanical Assembly 8 3 2 Floor Fixing 10 3 3 Electrical Connections 11 3 4 Connections for Digital I O...

Страница 6: ...tions of the equipment and local safety regulations Service of Rapiscan products shall be preformed only by a Rapiscan Systems qualified service provider or authorized contractor qualified service pro...

Страница 7: ...ment Failure to follow all such warnings cautions notices and instructions may result in damage to the equipment and or injury or death to personnel Such failure may also nullify any warranties provid...

Страница 8: ...tion at standby 11 W 12 VDC Ratings of recommended external power supply Voltage nominal 100 240 VAC Voltage absolute limits 90 264 VAC Frequency nominal 50 60 Hz Recommended operating conditions Ambi...

Страница 9: ...cs 4 Display and keypad 1 6 Zone displays 2 one in each coil panel 7 Traffic lights 1 Assembly First define the sides of the coil panels if you have side by side operation Zone displays are assembled...

Страница 10: ...he cables in corresponding connectors Check that connectors lock in position Re install the top piece and fasten it with the four screws DO NOT over tighten the screws as you may damage the thread in...

Страница 11: ...holes 1 in the panel boots to fix the unit to the floor with screws If drilling holes to the floor is not preferred you can use the flat areas under the boots to attach the unit to the floor with dou...

Страница 12: ...erial port connections 4 pcs all similar for Display and keypad Traffic lights MetorNet option Remote display option 6 Digital inputs 2 pcs 7 Digital outputs 2 pcs 8 SD memory card slot 9 Ethernet con...

Страница 13: ...sistor to 12 V Maximum input voltage is 15 VDC Recommended connection is a switch that connects input pin 1 to ground pin 3 Maximum load for each relay output is 24 V and 1 A WARNING Line voltage or a...

Страница 14: ...off with button C on the keypad During standby all displays and lights are off and metal detection is disabled with magnetic field generation turned off After switching on Metor 6E runs a self test Al...

Страница 15: ...there is a 5 0AT fuse F8 protecting the electronics Fuse type is Littlefuse Nanofuse 0454005 MR part number 58105674 WARNING Replace fuse only with equivalent type to avoid risk of fire 5 3 Replacing...

Страница 16: ...l 44 0 870 777 4301 Fax 44 0 870 777 4302 U S A Customer Service Center for Canada South America Caribbean Rapiscan Systems 2805 Columbia St Torrance CA 90503 USA Tel 1 888 258 6684 toll free for US c...

Отзывы: