SECTION 5 – GENERAL SPECIFICATIONS AND MAINTENANCE
– JLG Lift –
5-41
Lifting Chains
Lube Points - 4 chains (8E/20E), 6 chains (10E/26E)
Capacity: A/R
Lube - C (See Table 5-7)
Interval - After the first 50 hours of operation and every 125
hours of operation (or every 30 days) thereafter.
Lubricant can be applied manually with a brush or by spray
-
ing. Apply lubricant longitudinally and transversally for the
lubricant to reach the joints between the plates.
Table 5-13. Recommended Viscosity Grade
TEMPERATURE
ISO VISCOSITY GRADE
-15°C to 0°C (5° to 32°F)
15 to 32 mm
²
/s (cSt)
0°C to 50°C (32°F to 122°F)
46 to 150 mm
²
/s (cSt)
To
order
go
to