OSEE AURORA1600 Скачать руководство пользователя страница 1

 

 

 
 
 
 
 

AURORA1600 

1U 

Multi-image Processor 

 
 
 
 
 
 

User Manual

 

 
 
 
 
 
 
 
 
 
 
 
 

 

 

Содержание AURORA1600

Страница 1: ...AURORA1600 1U Multi image Processor User Manual...

Страница 2: ......

Страница 3: ...10100 Release Date November 5th 2015 Company OSEE TECHNOLOGY CO LTD Customer Support Address No 22 Building No 68 zone Beiqing Road Haidian District Beijing China Post Code 100094 Tel 86 010 62434168...

Страница 4: ...them better The safety matters or operations that user must pay attention to when using this product Contents The user manual applies to the following device types AURORA1600 The images of AURORA1600...

Страница 5: ...5 Chapter 3 Unpack and Installation 7 Chapter 4 AURORA1600 Features 11 4 1 Front Panel Features 11 4 2 Rear Panel Features 11 4 2 1 Arrangement of Rear Connectors 12 4 2 2 Operations of Rear Panel 12...

Страница 6: ......

Страница 7: ...he device integrates an internal control software to connect to and configure the controller You can configure multi walls and multi scene with the input video sources and set them at any position and...

Страница 8: ...de various detections on modules temperature and power supply Support SNMP for native and remote users to configure modules Functionality Support dual UMD dual TALLY and up to 8 channels of UV audio m...

Страница 9: ...Product Overview 3 SDI HDMI SDI SDI SDI Remote Control Computer Router Figure 1 2 The Topology of AURORA1600...

Страница 10: ......

Страница 11: ...ainst harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may caus...

Страница 12: ...missing or damaged Position Do not block any ventilation openings Do not use this unit near water Do not expose the unit to rain or moisture Do not install near any heat sources such as radiators hea...

Страница 13: ...king and Shipping This product was carefully inspected tested and calibrated before shipment to ensure years of stable and trouble free service Before you install this unit do the followings Check the...

Страница 14: ...n 1 Prepare for installation Make sure you have prepared the followings before mount the converter Inspect for any apparent physical damage that may have occurred in transit Make sure you have receive...

Страница 15: ...ault IP setting by short circuit two pairs of the corresponding pins of RS422 interface at the rear panel The instructions are as below Operations Firstly power down the AURORA1600 device insert a net...

Страница 16: ......

Страница 17: ...n or off The Multi image Processor performs the power supply input output and control functions through the corresponding modules and you should make sure the module has been inserted to the correct s...

Страница 18: ...t HDMI OUT1 HDMI OUT4 10 Audio Input AUDIO IN 1 16 11 Audio Output AUDIO OUT 1 4 12 Video Output SDI OUT 1 4 4 2 2 Operations of Rear Panel The details of these interfaces at the rear panel are descri...

Страница 19: ...4 Video Output BNC It provides four switch output interfaces they are labeled as SWITCH OUT1 SWITCH OUT4 Set any one of the input signals as a switch out signal to loop it out by tool software Figure...

Страница 20: ...vice control tool to modify the network settings The default IP address of AURORA1600 is 192 168 1 70 Restore the default IP setting by short circuit two pairs of the corresponding pins of RS422 inter...

Страница 21: ...2 The Relationship of Pins and Values for RS422 Pins Value 1 2 GND 3 Tx 4 Rx 5 Rx 6 Tx 7 8 GND 8 GPIO DB26 It provides one GPIO interface to realize the remote control function and you can set a func...

Страница 22: ...ed audio and HDCP using HDMI TypeA connector Figure 4 2 8 The HDMI Output Interface 10 Audio Input Interface DB26 It provides one audio input interface it is labeled as AUD IN 1 16 It supports 16 chan...

Страница 23: ...led as AUD OUT 1 4 It supports 4 pairs of audio output signals as shown in Figure 4 2 10 LINEC LINEA LINEB LINED 1 6 11 5 10 15 Figure 4 2 10 The Audio Output Interface The relationship of pins and va...

Страница 24: ...SDI 1080p50 60 59 94 4 2 3 Timing AURORA1600 provides the following timing methods LTC and native timing administration side 1 LTC Timing Use LTC timing through LTC port the conditions are as below 1...

Страница 25: ...rrent time or select as Timing yourself to a customized time as shown in Figure 4 2 12 click the manual timing button to confirm timing with the local time Figure 4 2 12 Timing Operation Window 4 3 Co...

Страница 26: ...es 20 multi image control software the software interface is shown in Figure 4 3 1 Figure 4 3 1 The Interface of the Multi image Control Software Refer to The Manual for the Multi image Controller Sof...

Страница 27: ...net RS422 TSL Display Units Up to 16 displays in a single screen Control Software AURORA Working Environment Work Temperature 0 70 Work Humility 10 90 no condense Height below 1000 feet 3048 meter abo...

Страница 28: ...00 mV pk pk 10 Signal Amplitude 800 mV pk pk 10 Overshoot 10 Jitter 0 2 UI Rise and Fall Time 700 ps for SD 270 ps for 1 5 Gb s HD 135 ps for 3 Gb s HD Extinction Ratio 8 Back Reflection 14 dB 2 Produ...

Страница 29: ...Specifications 23 Figure 5 4 Top View Unit mm Specifications are subject to change without notice No Text Below...

Страница 30: ......

Страница 31: ...E INFORMATION PLEASE VISIT http www osee dig com OSEE TECHNOLOGY CO LTD No 22 Building No 68 zone Beiqing Road Haidian District Beijing China Tel 86 010 62434168 Fax 86 010 62434169 E mail sales osee...