Optional: Connect your external buzzer (7) – use two crimp contacts, i.e.
5-160447-5 from TE-Connectivity.
Finally connect the Processing Unit with the power cable of the switch panel
through the Switchcraft hollow plug (4) – (it makes a “click”) and secure by
turning to the right and switching on electricity.
If the Power LED is red the system is turned on.
5.4. Cable specification
Generic
The cable dimensions must not exceed an outer diameter of minimum 4.5 mm
and a maximum of 7.1 mm. The coating needs to resist harsh maritime
conditions.
Power cable
The two wires need a cross section of 1.5 mm² and the material is tinned copper.
Recommended: LAPP ÖLFLEX® 440 P 0012837
Ethernet cable
Four copper wires each two twisted with a minimum cross section of 0.14 mm².
The twisted pairs need an overall shielding.
Recommended: LAPP UNITRONIC® ROBUST C (TP) 1032102
5.5.
Connectors
Power
●
Amphenol AD-02BFFA-LL7001
●
Switchcraft S761KS17