Volta Pellet Stove Installation and Operation Manual
__________________________________________________________________________________________________ 59
BURN POT AUGER
A
Screws
B
Auger and motor assembly
C
GASKET
NOTE: IF THE HOPPER AUGER MOTOR FAILED OR THE HOPPER AUGER IS JAMMED, TO AVOID
PELLET SPILLAGE, EMPTY THE HOPPER OF ITS CONTENTS BEFORE EXECUTING THE FOLLOWING
TESTS.
o
If the auger motor is defective, check to make sure that electrical connections are not loose
and that the auger isn’t jammed by an object.
o
If the auger is jammed, remove it from its housing. Disconnect the motor and then remove the
four screws on the steel plate that holds the auger shaft to the auger housing. To have an
easier access, remove the rear panel for an easier access. Pull out the auger from the housing.
Once the auger has been removed, make sure the auger is straight, that the surface is not
damaged and there are no burrs, or broken welds. Remove any foreign material that may
have caused the jam. Inspect the auger housing for signs of damage such as burrs, rough
spots, or grooves cut into the metal that could have caused a jam. Clean the auger housing
thoroughly to remove all pellet dust.
o
If no object appears to block the auger, reconnect the electrical connections of the motor and
turn on the stove.
BE CAREFUL NOT TO TAKE AN ELECTRIC SHOCK
. Test the motor using the
"TROUBLESHOOTING" mode.
The flue temperature sensor failed.
The “thermocouple” is a heat sensor located on the exhaust
motor housing. Its function is to tell the control board that the stove has ignited properly by
measuring the heat at the exhaust. When the stove is cold, check page 1 in the
“TROUBLESHOOT” menu if the temperature displayed on the line " EXHAUST TEMP" displays a