Volta Pellet Stove Installation and Operation Manual
54 __________________________________________________________________________________________________
given by the stove to understand what is the problem. It is thus important to read carefully this
section before calling technical support.
The following sections will help you test each component individually and will also give you many tips
in how to solve any problems related to a specific error message.
NOTE: IF YOU NEED TO CONTACT YOUR DEALER OR TECHNICAL SUPPORT, MAKE SURE TO HAVE
THE MODEL OF YOUR STOVE AND THE SERIAL NUMBER ON HAND. (THEY CAN BE FOUND ON THE
CERTIFICATION LABEL INSIDE THE HOPPER LID).
9.1
VALIDATING STATUS
When using your stove, you can validate at any time, the status of any of the following components:
-
Electronic components (low power rated)
o
F160 (security heat sensor)
o
L-250A (security heat sensor)
o
Pressure switch (security sensor)
o
Hopper switch (mechanical security sensor)
o
Thermostat (temperature regulator device)
-
Electrical components (high power rated)
o
Igniter (heater)
o
Combustion blower (will feed fire with fresh air)
o
Convection blower (will send hot air into the room)
o
Exhaust blower (will extract combustion gas out of the stove)
o
Auger motor 1 (located under the hopper)
o
Auger motor 2 (will feed the fire with pellets)
WARNING: RISK OF ELECTRICAL SHOCK. IF YOU NEED TO MANUALLY TEST, MANIPULATE OR
REPLACE ANY COMPONENTS, THE STOVE NEEDS TO BE DISCONNECTED FROM THE WALL OUTLET AS
WELL AS FROM THE OPTIONAL AUXILARY BATTERY SYSTEM.