Volta Pellet Stove Installation and Operation Manual
34 __________________________________________________________________________________________________
6.1.5
AUXILIARY BATTERY SYSTEM LEVEL
The batteries’ voltage at full load is 25.2V and the minimum voltage to avoid damaging the batteries
is 22.5V. When the minimum battery voltage is reached, the stove will automatically stop. The
batteries must be recharged or the stove must be connected to a power source.
Red
Indicates that the stove runs on the auxiliary battery system and the batteries are
25% load (until 22.5V).
Yellow
Indicates that the stove runs on the auxiliary battery system and the batteries are
50% load (until 23.6V).
Green
Indicates that the stove runs on the auxiliary battery system and the batteries are
at 75% load (until 24.5V).
Green
Indicates that the stove runs on the auxiliary battery system and the batteries are
full loads (until 25.2V).
Red
Indicates that the stove is powered, the batteries are 25% charged and that they
are charging.
Yellow
Indicates that the stove is powered, the batteries are 50% charged and that they
are charging.
Green
Indicates that the stove is powered, the batteries are 75% charged and that they
are charging.
Green
Indicates that the stove is on and the batteries are full loads.
6.1.6
ADJUSTING THE COMBUSTION LEVEL (HEAT OUTPUT)
Press on the
pellet burn rate
adjustment button
Press + or -
to adjust
the burn rate
The stove’s input range goes from 10,000 BTU/h to 45,000 BTU/h. To change combustion level,
select the flame icon
on the main status page to display the “+” and “-” combustion level settings.
Note: Input range may vary according to the type of pellets being used.
Even though your stove can burn a large variety of wood pellets, we strongly recommend the use of
high quality pellets to obtain maximum performance out of your stove (see
Section 5.2.1:
Proper
Fuel
). When using lower quality combustible, a restrictive venting system or using the stove in high
altitude, you may need to adjust the “PILOT ADJUSTMENT SETTING” and the “COMBUSTION
ADJUSTMENT SETTING”. These two (2) settings are available from the “SETUP” page.