Volta Pellet Stove Installation and Operation Manual
__________________________________________________________________________________________________ 15
sites), it is important to refer to it in order to have a safe and compliant installation. In addition, you
will find important information about your stove (model, serial number, etc.). You will find the
certification label on the inner side of the hopper lid of the stove.
3.2
MINIMUM CLEARANCES TO COMBUSTIBLES
WARNING: MINIMUM CLEARANCES IN THE TABLE BELLOW DO NOT TAKE INTO ACCOUND THE
MINIMUM SPACE NEEDED TO ALLOW THE LCD TOUCH SCREEN SLIDING SUPPORT TO MOVE FREELY
AND FULLY EXTENDED (SEE SECTION 3.3:
BACK WALL INSTALLATION
AND SECTION 3.4:
CORNER
INSTALLATION
).
LETTER
MINIMUN CLEARANCES TO
COMBUSTIBLES
CANADA
USA.
A*
1″ (25 mm)
1″ (25 mm)
B
4″ (102 mm)
4″ (102 mm)
C
1″ (25 mm)
1″ (25 mm)
D
Refer to vent manufacturer’s
clearances
Refer to vent manufacturer’s
clearances
I
54″ (1 372 mm)
54″ (1 372 mm)
LETTRE
RECOMMENDED CLEARANCES FOR MAINTENANCE
CANADA
USA
A*
12″ (305 mm)
12″ (305 mm)
B
24″ (610 mm)
24″ (610 mm)
C
12″ (305 mm)
12″ (305 mm)
D
Refer to vent manufacturer’s
clearances
Refer to vent manufacturer’s
clearances
* From the rear panel
Note:
These clearances are also valid for an
alcove
installation.
WARNING: IF THE STOVE IS INSTALLED IN AN ALCOVE, TO PERFORM MAINTENANCE, YOU SHOULD
EXPECT TO MOVE THE APPLIANCE TO GET TO THE MAINTENANCE ACCESS DOORS AND
COMPONENTS.