background image

1 - GENERAL DESCRIPTION

The OI 22-0 model is a digital indicator equipped with 1 input 

for PTC / NTC type probes. The process value is displayed on a 3-

digit red display.

OI 22 - 0

DIGITAL INDICATOR

PTC / NTC

FRONT PANEL

2 - TECHNICAL DATA

ELECTRICAL CHARACTERISTICS

 Power supply: 12 

VAC / DC - 100 ... 240 VAC +/- 10% AC frequency: 50/60 

Hz Consumption: 4 VA

Inputs: 1 input for NTC temperature probe (103AT-2,

USER MANUAL

10K 

Ω 

@ 25 ° C) or PTC (KTY 81-121, 990 

Ω 

@ 25 ° C) Power 

supply: type 1.B according to EN 60730-1

Overvoltage category: II 

Device class: Class II

Isolation : Isolated after part in low voltage (115/230 V power 

supply and relay output); and part in very low voltage inputs; 

Electrically isolated between outputs and power

INTRODUCTION:

This manual contains the necessary 

information for the correct installation and 

instruction for use and maintenance of the 

product, it is recommended that you read it 

carefully and keep it.

In order to avoid that an irregular operation 

of the THERMOSTAT or malfunction

.

In the event that they may create dangerous situations or 
damage to people or things or animals, it is recalled that the 
installation must comply with and take into account the 
annexed security systems, necessary to guarantee said security. 
OSAKA SOLUTIONS nor its legal representatives are not 
responsible for the inappropriate use of the THERMOSTAT or not 
in accordance with the characteristics of the THERMOSTAT.

MECHANICAL CHARACTERISTICS

 Body: UL 94 

V0 self-extinguishing plastic Heat and fire 

resistance category: D Dimensions: 78 X 35 

mm, depth 64 mm Weight: 120 g approx.

Installation: panel, recessed 71x29mm 

Connection: 2.5 mm terminal block

two

Degree of tightness: IP65-67

Ambient operating temperature: 0 T 50 ° C Operating ambient 

humidity: <95 RH% non-condensing

Transport and storage temperature: -25 T 60 ° C

INDEX

3

4

5

1  

GENERAL DESCRIPTION

TECHNICAL DATA

INSTALLATION

PROBLEMS, MAINTENANCE AND WARRANTY HOW TO 

MODIFY THE DECIMAL POINT PARAMETER, PROBE 

CALIBRATION AND CHOICE OF UNIT OF MEASURE

FUNCTIONAL FEATURES

Measuring range: NTC: -50 ... 109 ° C / -58 ... 228 ° F; PTC: - 50 ... 

150 ° C / -58 ... 302 ° F

Display resolution: 1 ° or 0.1 ° (range -99.9 ..99.9 ° C) Total 

precision: +/- (0.5% fs + 1 digit)

Measured velocity time (unfiltered): 130 ms 

Display : 3 Digits h 15.5 mm

Software structure class: A class

Accordance: Directive 2004/108 / CE (EN55022: class B; 

EN61000-4-2: 8KV air, 4KV cont .; EN61000-4-3: 10V / m; 

EN61000-4-4: 2KV power supply, inputs, outputs; EN61000- 4-5: 

2KV power supply comm. Mode, 1 KV \ diff. Mode; EN61000- 4-6: 

3V), 2006/95 / CE (EN 60730-1, EN 60730-2-7, EN 60730- 2-9 )