background image

 

7

 

 

ORTNER GmbH | Hürmer Straße 36 in A-3382 Loosdorf | Tel +43 2754 2707 | Fax +43 2754 2708  

[email protected] | www.ortner-cc.at 

 

Special instructions 

 

Please  note  that  the  surfaces  of  the  ST11  can  heat  up  strongly  during  the  heating  operation.  (Metal  parts,  ceramic 
glass)  The  ST11  is  designed  for  a  defined  maximum  wood  stacking  amount.  This  maximum  amount  may  not  be 

exceeded. The manufacturer’s warranty 

is voided in the event of prolonged overloading with an amount that is larger 

than specified as well as when using fuels that are not suitable.  
 

Any  warranty  obligation  of  the  manufacturer  is  voided  when  the  manufacturer’s  dimensional  specifications  for  t

he 

inlet  air  and  chimney  cross  section  are  not  adhered  to  or  are  modified  afterwards  irrespective  of  the  reason.  Any 
warranty obligation is voided in the event that constructional changes are performed on the unit. The floor must be 
able to bear the load and must be level. In the event of combustible flooring, a stable and non-combustible base must 
be used. This must protrude to the front by 30 cm and 10 cm to the side. Please observe the assembly instructions for 
the ST11. 
  
In particular, pay attention to the supply of inlet air when using fume hoods, central vacuum cleaning systems, housing 
ventilation or any other ventilation systems (risk of suffocation). Please consult your chimney sweep or stove fitter in 
this matter. 
Combustion air inlet openings may not be closed. 
Immediately alert the fire brigade in the event of a chimney fire and inform your chimney sweep. 
 
Breakage of the glass pane can occur as a result of mechanical overloading. This will create sharp parts 

 CAUTION! 

RISK OF INJURY. 

Commissioning 

 
Remove all documents and accessory parts present in the firebox.   
Press the operating lever fully into the open position.  
Stack up 11 kg hardwood logs with a length of approx. 33 cm (corresponds to about 3/4 of the combustion chamber 
height). Add finely chopped softwood on top and ignite this using firelighters (lighting wool, barbecue lighter). The fuel 
should rapidly be brought to a full fire.  
During stoking, the firebox door should not be shut completely during the first 5 minutes. You can close  the firebox 
door  as  soon  as  the  wood  begins  to  burn  properly.  The  maximum  wood  stacking  amount  should  not  be  exceeded. 
During  the  first  use,  a  slight  odour  nuisance  may  occur  (assembly  residue).  Should  this  be  the  case,  then  the 
installation space should be ventilated well in order to ensure the removal of the odours. 

Caution 

Under no circumstances use liquid or gaseous firelighters. 
Under  no  conditions  exceed  the  maximum  wood  stacking  amount  (11 kg).  When  using  the  minimum  wood  amount 
(5.5 kg), the firelighter  is positioned in the centre of the wood stack. The firing installation  is operated in temporary 
burning. In order to achieve the maximum output with a heating interval of 12 h, this process must be repeated after 
12 h (KMS 300). 

Note 

Because moisture is introduced during the construction of the unit, steam formation may occur in the event of intense 
heating.  This  can  cause  the  formation  of  cracks;  for  this  reason,  the  unit  must  be  heated  dry  before  plastering  is 
carried out. For this, place around 6 kg hardwood logs with a length of approx. 33 cm in the combustion chamber, light 
this with a suitable firelighter in the centre of the wood stack and allow the wood to burn off. Repeat this process 2 to 
3 times. 
 

 

 

 

Содержание ST11 42/59

Страница 1: ...lation the operating manual must be read disregard of the instructions will lead to the voiding of the manufacturer s warranty The respective national or local regulations and general provisions and codes of practice must be complied with Do NOT use this firing installation as a waste incinerator Version 10_2016 ...

Страница 2: ...1 ORTNER GmbH Hürmer Straße 36 in A 3382 Loosdorf Tel 43 2754 2707 Fax 43 2754 2708 office ortner cc at www ortner cc at ...

Страница 3: ...ng substances 6 Special instructions 7 Commissioning 7 Caution 7 Note 7 Cleaning and maintenance 8 Caution 8 Troubleshooting 9 The draught of the stove is insufficient the fire almost goes out Caution Risk of deflagration 9 Flue gas leakage from the stove 9 The stove does not become sufficiently warm 9 Condensate escapes from the stove pipe and the chimney becomes wet and sooty 9 The wood does not...

Страница 4: ... the stove can only be ensured under adherence of all requirements specified in the operating manual The ST11 42 59 has been verified in accordance with EN13229 and additionally complies with the following national emissions requirements CO mg MY NOx mg MY OGC mg MY Dust mg MY Austria 15a Environmental label UZ 37 1100 700 150 120 50 50 35 30 80 80 Germany BIMSchV 2nd stage 2015 830 27 70 80 Switz...

Страница 5: ...purposes Racks for the drying of clothing must be positioned at a sufficient distance from the heating unit The handling of highly combustible or explosive substances is prohibited during the operation of the stove Remove the ash in the combustion chamber in a timely manner in order to prevent the blocking of the inlet air openings Before each lighting ensure both an unimpeded sufficient inlet air...

Страница 6: ... the wood can be ignited In order to prevent the release of heating gas the firebox door must always be closed except during lighting when refilling with fuel and during ash removal In order to refill fuel the door may only be opened after the wood has been burnt shortly before the embers phase Control elements and their function in automatic operation The dual pane glass door is opened or closed ...

Страница 7: ...posits pitch like deposit on the inside of the pane on the ceramic components as well as the chimney risk of a chimney fire Wood will only achieve an optimal heating value when it has been stored dry and ventilated under a roof for at least two years The logs should have an equal length and have a weight of 1 2 kg In regard to the length pay attention that the wood fits correctly in the combustion...

Страница 8: ... overloading This will create sharp parts CAUTION RISK OF INJURY Commissioning Remove all documents and accessory parts present in the firebox Press the operating lever fully into the open position Stack up 11 kg hardwood logs with a length of approx 33 cm corresponds to about 3 4 of the combustion chamber height Add finely chopped softwood on top and ignite this using firelighters lighting wool b...

Страница 9: ...ed in cold condition Have the cleaning of the chimney the connection piece between the chimney and the firing installation and the ceramic components of the masonry heater performed regularly by a licensed specialist in accordance with the country specific regulations A blockage of the chimney may occur as a result of a prolonged interruption of the operation Therefore before each start up verify ...

Страница 10: ...ey or an insufficient draught is present due to a higher outside temperature during the transition period If necessary install wind protection on the chimney The stove does not become sufficiently warm Check the wood s moisture content Condensate escapes from the stove pipe and the chimney becomes wet and sooty Possible causes are exhaust gas temperatures or chimney temperatures that are too low I...

Страница 11: ...10 ORTNER GmbH Hürmer Straße 36 in A 3382 Loosdorf Tel 43 2754 2707 Fax 43 2754 2708 office ortner cc at www ortner cc at ...

Отзывы: