background image

New batteries need charging before your first journey and will not perform 

to their peak until the first six to ten charging cycles have been completed. 

To ensure long battery life does not allow your batteries to become totally 

discharged. If your powered wheelchair is not used for any length of time the 

batteries must receive a full charge once a month and remain fully charged 

during storage. For replacement batteries contact Greencare in order to 

ensure that the new batteries are of the correct type and specification and 

are correctly installed and connected.

Pay attention to the battery charge indicator on the joystick controller as at 

full charge all lights will be on (from right to left: green, amber, and red). As 

the battery charge drops during powered wheelchair operation successive 

lights will extinguish until eventually only the two red lights will be on. It means 

that you must charge the batteries without delay. We strongly advise you, 

however, not to wait until this critical point has been reached but to charge 

the batteries as early and as often as possible after you have used your 

powered wheelchair. If you ignore the warning (only two red lights on), and 

the battery charge drops further to a level where it is no longer sufficient to 

allow safe driving, the controller will automatically cut the power supply to 

the motors, so that the powered wheelchair comes to an abrupt halt and you 

may find yourself stranded.

Except in emergencies, never drive on discharged batteries, this will add strain 

to them and reduce their life. We recommend batteries should be charged 

every time the powered wheelchair is used, independent of the depth of 

discharge. Depending on this and their capacity, a full charge on completely 

discharged batteries can take up to approximately eight hours.

CHARGING PROCEDURES

IMPORTANT:

Before you attempt charging, ensure you read and understand the instruction 

leaflet supplied with the battery charger.

44

Содержание Greencare EP1C

Страница 1: ...Instructions for Use EP1C wheelchair...

Страница 2: ...ore using the product and observe the safety notices Please instruct the user on the safe use of this product Please contact the manufacturer if you have any questions or issues with the product Pleas...

Страница 3: ...d backrests 29 Setting up the joystick remote 30 Limitations of use PLEASE READ 32 Disengaging motors 32 Generaluseradviceandroutinemaintenance 33 Using your wheelchair safely 34 Movingsafelyandenviro...

Страница 4: ...ons Manufacturer address Maximum safe slope Unique device identifier Catalogue No Wheelchair depth Wheelchair width Warning Date of manufacture Lot or batch number Max load User weight Medical device...

Страница 5: ...re reading this document make sure you have the latest version You find the latest version as a PDF on the Greencare website If you find that the font size in the printed document is difficult to read...

Страница 6: ...e disability yet proper operation of an electromotive drive unit is still practicable CONTRAINDICATIONS There are no contraindications known TYPE CLASSIFICATION The mobility device with a maximum spee...

Страница 7: ...ted due to the lighting system if fitted failing or being defective reflectors falling off worn thread or insufficient tire pressure damage to the armrests e g torn armrest padding damage to the leg r...

Страница 8: ...e user manual Incorrect use Natural wear and tear Incorrect assembly or set up by the purchaser or a third party Technical modifications Unauthorised modifications and or use of unsuitable spare parts...

Страница 9: ...ability to operate a vehicle is impaired by medication or alcohol Never drive the mobility device under the influence of medication or alcohol If necessary the mobility device must be operated by an...

Страница 10: ...sharp stop If you have to brake in an emergency simply release the joystick which will bring you to a halt refer to the remote user manual for more information CAUTION Risk of injury when transferring...

Страница 11: ...y or damage Avoid storing or using the mobility device near open flame or combustible products CAUTION Risk of injury if maximum permissible load is exceeded Do not exceed the maximum permissible load...

Страница 12: ...ices being connected Do not connect any electric devices to your mobility device that are not expressly certified Greencare for this purpose Have all electrical installations done by your authorized G...

Страница 13: ...ained or covered with non conductive materials so that they are not exposed to human contact or materials that could cause electrical shorts When cables with live pins have to be disconnected for exam...

Страница 14: ...damaged DO NOT remove fuse or mounting hardware from POSITIVE red battery cable mounting screw WARNING Risk of death or serious injury Electric shock can cause death or serious injury To avoid electri...

Страница 15: ...transceivers or cellular phones when the mobility device is switched on Avoid getting near strong radio and television transmitters In case the mobility device should be set in motion unintentionally...

Страница 16: ...come an obstacle when on an uphill or downhill gradient Never attempt to drive up or down a flight of steps with your mobility device Avoid shifting your centre of gravity as well as abrupt joystick m...

Страница 17: ...otplates and that both leg rests are properly locked into place WARNING Risk of injury if you collide with an obstacle when driving through narrow passages such as doorways and entrances Drive through...

Страница 18: ...m They lose their effect and the mobility device can tip over Only drive with extreme care on soft ground especially during uphill and downhill journeys In the process pay increased attention to the t...

Страница 19: ...ient to carry out intermediate checks on the brakes accessories and running gear If the mobility device is to be operated on public roads the vehicle driver is responsible for ensuring that it is in a...

Страница 20: ...ronic components which have not been approved by Greencare for use with this mobility device can cause fire hazards and lead to electromagnetic damage Only ever use electrical and electronic component...

Страница 21: ...hair description code and batch date are on a label on the rear cross brace This can be read from the back of the chair Each wheelchair has its own specific identification code serial number This numb...

Страница 22: ...isfy themselves as to the competence in use of the chair in the environment in which it will be used Occupant driving skills and transfers in and out of the wheelchair and accessibility within the int...

Страница 23: ...uvring your powered wheelchair Ensure power is switched off before transferring to or leaving your powered wheelchair Before switching on check that both motors are engaged and tyres are in good condi...

Страница 24: ...e backrest lift the push handles Backrest latches on each sidewall click into position when the push handle is fully up provided that the back brace tension is released When the backrest catches locat...

Страница 25: ...ins the upright position when folded The thicker more supportive tension adjustable back cushion if fitted is attached by Velcro to inner adjustable support frame straps and can be removed for transpo...

Страница 26: ...e or double it is important to recognise that lower limb amputation will affect the sitting centre of balance of the wheelchair The impossibility of generalising the individual ability of a wheelchair...

Страница 27: ...d normally be removed for storage For complete footrest bracket removal continue to lift so that the upper pivot clears the front tube location When removed place the footrests carefully in a safe pos...

Страница 28: ...m to change foot position whilst seated Single piece footboards are also available A rigidly mounted adaptable footboard for small size wheelchairs and a dynamic footboard for use in a compact indoor...

Страница 29: ...ctural plastic which has some flexibility or rigid aluminium as determined by the assessment When chairs are built for narrow access the rigid side panel reduces sideways flexing Side panels should be...

Страница 30: ...t of the chair is now possible by gentle adjustment of the joystick In the direction you want to travel Speed can be regulated by moving the knob around the central button in an anti clockwise directi...

Страница 31: ...ate any warranty and COULD BE DANGEROUS and harm thewheelchair user Performance adjustments will be made by wheelchair provider professionals or fully trained persons to take account of the driver s c...

Страница 32: ...isengaging motors To disengage the motors to allow for the chair to be moved without the use of power you must operate the red lever on the side of each motor unit This disengagement removes the motor...

Страница 33: ...fident in wheelchair use within their environment Users and carers who are unfamiliar with wheelchair use should pay particular attention to safety advice when transferring in and out of the wheelchai...

Страница 34: ...l for the occupant to transfer in and out of the wheelchair into another chair or supporting surface The wheelchair should be positioned so that the distance from one support to the other is minimal a...

Страница 35: ...ivelled back it will allow sideways entry to the chair and vice versa from another chair or car seat Some physically active independent users with upper body and arm strength may develop skill to carr...

Страница 36: ...d not attempt to change footrest positions without consultation with the wheelchair service Building Regulations recognise the requirement for wheelchair access Users have a responsibility to bring co...

Страница 37: ...s fitted and are always supplied Generally kerbs must be avoided access ramps to be used wherever available Accessibility factors in the intended usage environment such as doors kerbs or ramps may dem...

Страница 38: ...should be individually assessed and separately advised Cushions and upholstery USE OF CUSHIONS AND UPHOLSTERY CARE Greencare upholstery is padded and comfortable for short term use The material is st...

Страница 39: ...ct support including an allowance for the cushion thickness If the occupant uses the chair set up in this way without a cushion localised pressure on the body contact in the seating area will be incre...

Страница 40: ...al wheelchair service for advice It is most important that the Assessment Teams are fully satisfied with user skills and acceptance of responsibility before allowing use of an EP1C wheelchair An atten...

Страница 41: ...independent occupant who chooses to travel in a wheelchair good accessibility into confined spaces is important when using the allocated spaces on public transport such as low floor buses USE OF FOUR...

Страница 42: ...ourney planning eliminates the need for vehicles to encounter surface hazards Wheelchair posture belts and lap straps are not tested to meet the crash test standards but we advise that they should con...

Страница 43: ...ndle the battery charger with care if it has been dropped or damaged do not use it Do not use an extension lead for connection from the mains to the charger unless absolutely necessary If you do use o...

Страница 44: ...It means that you must charge the batteries without delay We strongly advise you however not to wait until this critical point has been reached but to charge the batteries as early and as often as pos...

Страница 45: ...rging lights on the charger will come on It is recommended the charger is left connected as described until the Full Charge light illuminates to obtain optimum performance of the batteries When the Ch...

Страница 46: ...uids EMI REGULATION CONFORMITY The Greencare EP1C wheelchair has been successfully tested in accordance with international standards as to its compliance with Electromagnetic Interference EMI regulati...

Страница 47: ...configuration error Check cables and connectors Check bluetooth pairing Reconfigure the system Recharge the battery Check charger Replace modules Contact supplier 3 Left motor error Check cables and...

Страница 48: ...clear the error indication cycle the system s power For more information about the error and what to do about it open the logs within one of the programming diagnostic tools see 10 1 The LiNX Access...

Страница 49: ...users with the reliability comfort and independence needed for a more improved lifestyle in modern environment Greencare has a policy of constant product improvement and reserves the right to change s...

Страница 50: ...bility Matters Group Ltd Ability House Nuffield Way Abingdon Oxfordshire United Kingdom OX14 1RL Version 1 00 28 May 2021 44 0 1235 552 895 info ortho europe com ortho europe com greencaremobility com...

Отзывы: