Fireplace Restrictors and Flue Arrangement
The information and tables in this section will help you calculate the correct restrictor selection. The tables show
the options permitted for both vertical and horizontal positioning of the flues and the required restrictor. Any
flueing pathway that does not appear in the tables requires approval from the manufacturer.
The tables presented below apply to both Natural Gas and Universal LPG
. The tables represent manufacturer’s
guidelines. Environment gas type (NG vs. LPG and the source of the gas) and other factors may affect the best
restrictor choice.
NOTE: If the flame appears to be atypical, please contact ORTAL for alternate restrictor size
recommendations.
The following symbols are used in the tables:
x
X:
The path is not allowed.
x
0:
There is no restriction.
x
Numbers other than zero:
The number represents the width required for the size of restrictor that has
to be assembled. All these dimensions are shown in cm/mm.
If the length (vertical or horizontal) does not appear in the table, consult with ORTAL before proceeding. For
special flueing systems, please contact ORTAL for more information.
NOTE: Space Creator models may require special restrictors. Traditional models do not require
restrictors.
For Series 150-170:
x
A minimum 90cm vertical run is required before any 90-degree bends.
x
A 45-degree offset is allowed for maximum 30cm. This must be followed by a 90cm vertical run before
offset, 90-degree bend or termination.
For the correct size flue, refer to Product List: Models and Burners on page 11. The approved flue system
components are labelled for identification. Do NOT combine flue components from different manufacturers with
these appliances. Please follow the
manufacturer’s instructions for
flue system installation.
For Series 200-250:
x
A minimum 180cm vertical run is required before any 90-degree bends.
x
A 45-degree offset is allowed for maximum 30cm. This must be followed by a 180cm vertical run
before offset, 90-degree bend or termination.
The approved flue system components are labelled for identification. Do NOT combine flue components from
different manufacturers with these appliances. Please follow the manufacturer’s instructions for
flue system
installation.
WARNING
–
Fire hazard is an extreme risk if these clearances (air space) to combustible materials are not
adhered to. It is of the greatest importance that the fireplace and flue system are installed in accordance with
these instructions.
Содержание Clear 200
Страница 1: ...Installation and Operation Manual AU NZ For 150 250 Units ORTAL Heating Systems Ltd ...
Страница 17: ...17 LEFT SIDE OPEN LS RIGHT SIDE OPEN RS THREE SIDES TS ...
Страница 21: ...21 Figure 3 Concrete Wall Mounting Detail ...
Страница 23: ...23 Figure 4 Wood Stud Mounting Detail ...
Страница 43: ...43 Figure 12 Exploded View of Pilot Parts Receiver and Gas Valve ...
Страница 55: ...55 Figure 12 Exploded View of Pilot Parts Receiver and Gas Valve ...
Страница 77: ...77 Flue Termination Drawings Flue Terminations ...
Страница 89: ...89 Pull the suction cup to take the glass out NOTE Repeat this process to remove the side glass ...
Страница 102: ...102 Pull the framed screen down and out and remove it ...
Страница 120: ...120 6 Push the right and left floor bricks into place as shown ...
Страница 125: ...125 ...
Страница 135: ...135 ORTAL Product Service Log ...
Страница 136: ...136 Manufacturer Contact Information For all service issues please contact your local dealer ...
Страница 146: ...146 Troubleshooting Beeping ...
Страница 147: ...147 ...
Страница 148: ...148 Mertix Maxitrol External Source Operation The following figure is taken from the Mertix Maxitrol guide ...
Страница 154: ...154 Pull the base until it releases Tilt the base as shown in the figure below ...
Страница 155: ...155 Pull the base out as shown ...
Страница 156: ... Ortal 2018 Rev 3 0 October 2018 KPMANUALAUAGA ...