formats, the least significant bit occurs first. All unused Control Functions are filled
with a space (Binary 0).
SBS
: Word begins at index count 80. Seventeen Straight Binary Coded elements
occur with a position identifier between the 9th and 10th binary coded elements.
Least significant digit occurs first.
Pulse rates:
Element rate: 100 per second.
Position identifier rate: 10 per second.
Reference marker rate: 1 per second.
Element identification: The "on time" reference point for all elements is the pulse
leading edge.
Index marker (Binary 0 or uncoded element): 2 millisecond duration.
Code digit (Binary 1): 5 millisecond duration.
Position identifier: 8 millisecond duration.
Reference marker, 1 per second. The reference marker appears as two consecutive
position identifiers. The second position identifier marks the on-time point for the
succeeding code word.
Resolution:
Pulse width coded signal: 10 milliseconds.
Amplitude modulated signal: 1 millisecond.
Carrier frequency: 1kHz when modulated.
Table 5-4:
IRIG B control function field
C.F. Element # Digit #
Function
50
1
Space
51
2
Space
52
3
Space
53
4
Space
54
5
Space
55
6
Time Sync Status
56
7
Space
VelaSync 1232 User Manual
227
APPENDIX
Содержание Spectracom VelaSync 1232
Страница 2: ......
Страница 4: ...Blank page II VelaSync 1232 User Manual...
Страница 12: ...BLANK PAGE X VelaSync 1232 User Manual TABLE OF CONTENTS...
Страница 28: ...16 CHAPTER 1 VelaSync 1232 User Manual Rev 4 1 7 The VelaSync Web UI...
Страница 34: ...BLANK PAGE 1 9 Regulatory Compliance 22 CHAPTER 1 VelaSync 1232 User Manual Rev 4...
Страница 264: ...BLANK PAGE 252 VelaSync 1232 User Manual...