EPSILON CLOCK MODEL EC20S
Spectracom
61
User’s Manual
45.
EXTERNAL 1PPS FAULT
- Yes
Generates a trap when the External 1PPS is lost (while enabled).
- No
No trap is generated.
46.
NMEA FAULT
- Yes
Generates a trap when the NMEA input is lost (while enabled).
- No
No trap is generated.
47.
INTERNAL OSCILLATOR FAULT
- Yes
Generates a trap when the frequency driver goes on alarm
(generally the oscillator goes on default).
- No
No trap is generated.
48.
INTERNAL 1PPS FAULT
- Yes
Generates a trap when the 1PPS driver goes on alarm.
- No
No trap is generated.
49.
PHASE ACCURACY FAULT
- Yes
Generates a trap when estimated phase of the output signal
exceeds the phase limit.
- No
No trap is generated.
50.
FREQUENCY ACCURACY FAULT
- Yes
Generates a trap when estimated frequency of the output signal
exceeds the phase limit.
- No
No trap is generated.
51.
SYNCHRONIZATION SOURCE CHANGE
- Yes
Generates a trap when the source of synchronization changes.
- No
No trap is generated.