![Orolia Seven Solutions WR-ZEN Series Скачать руководство пользователя страница 50](http://html1.mh-extra.com/html/orolia/seven-solutions-wr-zen-series/seven-solutions-wr-zen-series_user-manual_1654218050.webp)
Figure 4-11:
Example of gpa_ctrl usage to list power supplies parameters.
The list of related parameters displays in 5 columns:
1.
The state of the parameters. In this example only the status of the right power sup-
ply (0.9120.1) is in a critical state (C).
2.
The OID of the parameter.
3.
The path of the parameter inside the module.
4.
The value of the parameter.
5.
The unit of the parameter (if relevant).
The user can also list only the parameters related to the right power supply by executing:
gpa_ctrl hald pws/pwsr
/
4.4.1.1
Readback a specific parameter
It might also be interesting to only readback a specific parameter. To only get the status of
the left and right power supplies the user should execute:
root@z16- 006:~#
gpa_ ctrl
hald
pws/pwsl/status;
echo
$?
OK
0
root@z16- 006:~#
gpa_ ctrl
hald
pws/pwsr/status;
echo
$?
Warning:
C
pws/pwsr/status
NOT
DETECTED
204
40
CHAPTER
4
•
WR-Z16 User Manual Rev. v3.4
4.4 CLI Monitoring
Содержание Seven Solutions WR-ZEN Series
Страница 1: ...WR Z16 MODEL User Manual Revision v3 4 Date 14 October 2022 ...
Страница 2: ......
Страница 4: ...Blank page II WR Z16 User Manual ...
Страница 16: ...BLANK PAGE 1 4 About White Rabbit High Accuracy Technology 6 CHAPTER 1 WR Z16 User Manual Rev v3 4 ...
Страница 38: ...BLANK PAGE 3 2 Connecting to the Device 28 CHAPTER 3 WR Z16 User Manual Rev v3 4 ...
Страница 104: ...BLANK PAGE 6 5 Firewall 94 CHAPTER 6 WR Z16 User Manual Rev v3 4 ...
Страница 144: ...BLANK PAGE 8 5 Failsafe Mode 134 CHAPTER 8 WR Z16 User Manual Rev v3 4 ...
Страница 167: ...V Virtual Clock 47 W Web GUI 32 White Rabbit 2 58 WR 2 WRZ OS 3 WR Z16 User Manual iii INDEX ...