Parameter
Unit
Range
Description
a
0
m
±10000 Clock bias measured at t
0
.
a
1
m/s
±100
Clock drift at t
0
.
a
2
m/s² ±10
Rate of clock drift.
At the time
t
, the clock offset is then calculated as follows:
Δ
t
= t – t
0
bias (meters) = a
0
+
Δ
t
( a
1
+ 0.5 *
Δ
t
* a
2
)
Note
SOURce:CLKMDL commands are accepted only while a scenario is running.
Example
SOUR:SCEN:CLKMDL 10.000000,2000.000000,-10.000000,0.000000
6.3.3.95 SOURce:SCENario:CLKMDL?
Note:
This SCPI command is only supported if the Spoofing Range Option is
installed (OPT-SPF license, see
"GSG Series Model Variants and Options"
.)
Function
The
Clock Model
command is used in the context of simulating the spoofing of mobile
equipment.
This command is used to query the Clock Model state and its parameters t, bias, t
0
, a
0
, a
1
,
and a
2
. See also:
"SOURce:SCENario:CLKMDL" on the previous page
.
Command Syntax
SOURce:SCENario:CLKMDL?
Return
t: scenario elapsed time in seconds when the query was handled (and when the bias
was calculated).
bias: clock bias at time t.
t
0
, a
0
, a
1
, a
2
: the current clock model parameters
312
User Manual GSG-5/6 Series Rev. 27
6.3 Command Reference
Содержание GSG-5 Series
Страница 2: ......
Страница 4: ...Blank page II User Manual GSG 5 6 Series...
Страница 42: ...BLANK PAGE 2 5 Signal Power Level Considerations 26 User Manual GSG 5 6 Series Rev 27...
Страница 382: ...BLANK PAGE 6 7 Revision History SCPI Guide 366 User Manual GSG 5 6 Series Rev 27...
Страница 388: ...BLANK PAGE vi User Manual GSG 5 6 Series...