<mode>
could be ONCE/FOREVER/LOOPING.
If only
<duration>
is given, then
<mode>
is ONCE by default.
If
<mode>
is FOREVER,
<duration>
cannot be specified.
Notes
This command changes duration of the currently loaded scenario, but does not change the
scenario file, so that when you try to edit the scenario, you will see unchanged parameters
from the file.
Examples
SEND:
SOUR:SCEN:DURATION ONCE,3600
Set scenario duration to 1 hour, executed once.
SOUR:SCEN:DURATION FOREVER
Set scenario duration to forever.
SOUR:SCEN:DURATION 600
Set scenario duration to 10 minutes, executed once.
6.3.3.88 SOURce:SCENario:DURATION?
Function
Inquires the duration of the scenario (
<duration>
specified in seconds).
Command Syntax
SOURce:SCENario:DURATION?
Return
Returns pair
<mode>
,
<duration>
.
<mode>
can be ONCE/FOREVER/LOOPING.
Example
QUERY:
SOUR:SCEN:DURATION?
306
User Manual GSG-5/6 Series Rev. 27
6.3 Command Reference
Содержание GSG-5 Series