6.1.10 LLDP
LLDP Configurations
This page allows you to examine and configure current LLDP port settings.
Label
Description
Tx Interval
The switch periodically transmits LLDP frames to its neighbors to
update the network discovery information. The interval between
each LLDP frame is determined by the Tx Interval value which
must be between 5 - 32768 seconds.
Tx Hold
Each LLDP frame contains information about how long time the
information in the LLDP frame shall be considered valid.
The LLDP information valid period is set to Tx Hold multiplied
by Tx Interval seconds. Valid values must be between 2 - 10
times.
Tx Delay
When a setting is changed (e.g. the IP address), a new LLDP
frame is transmitted, but the time between the LLDP frames will
always be at least the value of
Tx Delay
seconds.
Tx
Delay
cannot be larger than 1/4 of the
Tx Interval
value. Valid
values must be between 1 - 8192 seconds.
Tx Reinit
When an interface is disabled, LLDP is disabled or the switch is
rebooted, a LLDP shutdown frame is transmitted to the
neighboring units, signaling that the LLDP information isn't valid
anymore. Tx Reinit controls the amount of seconds between the
shutdown frame and a new LLDP initialization. Valid values must
be between 1 - 10 seconds.