P1
P2
ETH
10/100/1000M
DPX
LNK/ACT
2
LFP
Fault
LNK/ACT
Speed
P2
P1
LFP
SW 1
Fail Close
Fail Open
Fault Relay
SW 2
1
LFP
LFP
stop
PoE
IGPMC-111GP
PoE
100
100/1000X
Quick Installation Guide
Version 1.0
Q
uick
I
nstallation
G
uide
Introduction
PRINTED ON RECYCLED PAPER
Q I G
IGPMC-111GP
1907-2-29-IGPMC111GP-1.0
The
is a cost-effective solution for conversion between
10/100/1000Base-T(X) and 100/1000Base-X SFP interfaces, allowing you to
extend communication distance by optical fiber. The device supports
MDI/MDIX auto detection, so you don’t need to use crossover wires. With a
10/100/1000Base-T(X) P.S.E. (Power Sourcing Equipment) port, the device
can transmit electrical power up to 30 watts, along with data, to remote
devices over standard twisted-pair cable in an Ethernet network. It also
supports LFP (Link Fault Pass-through). When one side of the link fails,
the other side continues to transmit packets and will wait for a response
that never arrives from the disconnected side. LFP can be easily enabled
using the DIP switch. Once enabled, the link will shut down as soon as it is
notified that the other link has failed, giving the application software a chance
to react to the situation. The
has a wide operating
temperature range from -40~75°
and a wide voltage range between
50~57 VDC, so it is suitable for harsh operating environments.
IGPMC-111GP
IGPMC-111GP
C
Package Contents
Installation
The series is shipped with the following items. If any of these items is missing
or damaged, please contact your customer service representative for
assistance.
Preparation
Before installation, make sure you have all of the package contents
available and a PC with Microsoft Internet Explorer 6.0 or later, for using
web-based system management tools.
Elevated Operating Ambient:
Reduced Air Flow:
If installed in a closed cabinet, the operating
ambient temperature of the rack environment may be greater than room ambient.
Therefore, consideration should be given to installing the equipment in an
environment compatible with the maximum ambient temperature (Tma) specified
by the manufacturer.
Installation of the equipment should be such that the
amount of air flow required for safe operation of the equipment is not
compromised.
Safety & Warnings
Contents
Wall-mount Kit
DIN-rail Kit
IGPMC-111GP
Pictures
Number
X 2
X 1
QIG
X 1
Dimension (Unit: mm)
X 1
Step 1:
Step 2:
Slant the switch and screw the Din-rail kit onto the back of the switch, right in the
middle of the back panel.
Slide the switch onto a DIN-rail from the Din-rail kit and make sure the switch clicks into
the rail firmly.
DIN-rail Installation
Step 1:
Step 2:
Step 3:
Screw the two pieces of wall-mount kits onto both sides of the switch. A
total of eight screws are required, as shown below.
Use the switch, with wall mount plates attached, as a guide to mark the correct
locations of the four screws.
Insert four screw heads through the large parts of the keyhole-shaped apertures, and
then slide the switch downwards. Tighten the four screws for added stability.
Wall-mounting
Media
C o nv ert e r
Media
C o nv ert e r
I N D U S T R I A L
4-pin terminal block
X 1
70.0
20.0
43.5
33.6
12.5
28.0
20.0
22.0
29.0
13.1
22.6
8.0
14.0
13.5
40.0
50.0
25.3
41
19.0
IGPMC-111GP
Mechanical Loading:
Circuit Overloading:
Mounting of the equipment in the d
should be such that
a hazardous condition is not achieved due to uneven mechanical loading.
Consideration should be given to the connection of the equipment to
the supply circuit and the effect that overloading of the circuits might have on overcurrent
protection and supply wiring. Appropriate consideration of equipment nameplate ratings
should be used when addressing this concern.
in-rail
41.0
95.0
Panel Layouts
Front Panel
1. Power LED
2. LNK/ACK LED for SFP port
3. PoE power status
4. LFP status LED
5. Fault LED
6. Duplex LED for Giga port
7. SFP port
8. DIP-switch 2
9. Giga port LNK/ACT LED
10. Giga port
11. Giga port speed LED
12. DIP-switch 1
13. Faulty terminal
Top Panel
1
2
1. Wall-mount screw
holes
2. Terminal block
Real Panel
1
1. Din-rail screw holes
1
2
3
4
5
6
7
8
10
9
11
12
13
Industrial Gigabit PoE Media
Converter
P1
P2
ETH
10/100/1000M
DPX
LNK/ACT
2
LFP
Fault
LNK/ACT
Speed
P2
P1
LFP
SW 1
Fail Close
Fail Open
Fault Relay
SW 2
1
LFP
LFP
stop
PoE
IGPMC-111GP
PoE
100
100/1000X
P1
P2
ETH
10/100/1000M
DPX
LNK/ACT
2
LFP
Fault
LNK/ACT
Speed
P2
P1
LFP
SW 1
Fail Close
Fail Open
Fault Relay
SW 2
1
LFP
LFP
stop
PoE
IGPMC-111GP
PoE
100
100/1000X