IES-2060 & IES-242FX-MM/SS SERIES User Manual
ORing Industrial Networking Corp
37
T
echnical Specifications
ORing Switch Model
IES-2060
IES-2042FX-MM-SC
IES-2042FX-SS-SC
Physical Ports
10/100Base-T(X) Ports in RJ45 Auto
MDI/MDIX
6
4
4
Fiber Ports
Specifications
Fiber Ports
Number
-
2
2
Fiber Ports
Standard
-
100Base-FX
100Base-FX
Fiber Mode
-
Multi-mode
Single-mode
Fiber Diameter
(
µ
m)
-
62.5/125 µm
50/125 µm
9/125 µm
Fiber Optical
Connector
-
SC
SC
Typical Distance
(km)
-
2 Km
30 Km
Wavelength
(nm)
-
1310 nm
1310 nm
Max. Output
Optical Power
(dBm)
-
-14 dbm
-8 dbm
Min. Output
Optical Power
(dBm)
-
-23.5 dbm
-15 dbm
Max. Input
Optical Power
(Saturation)
-
0 dbm
0 dbm
Min. Input
Optical Power
(Saturation)
-
-31 dbm
-34 dbm
Link Budget (dB)
-
7.5 db
19 db
Technology
Ethernet Standards
IEEE 802.3 for 10Base-T
IEEE 802.3u for 100Base-TX
IEEE 802.3x for Flow control
IEEE 802.1D for STP (Spanning Tree Protocol)
IEEE 802.1w for RSTP (Rapid Spanning Tree Protocol)
IEEE 802.1AB for LLDP (Link Layer Discovery Protocol)
MAC Table
1K
Packet buffer
1Mbits
Priority Queues
4
Processing
Store-and-Forward
Switch Properties
Switching latency: 7 µs
Switching latency: 5.05 µs
Switching latency: 7.45 µs
Switching bandwidth: 1.2Gbps
Throughput (packet per second): 76.19Mpps@64Bytes packet
VLAN: Port based
Security Features
Enable/disable ports
VLAN to segregate and secure network traffic
Software Features
STP/RSTP (IEEE 802.1D/w)
Redundant Ring (O-Ring) with recovery time less than 10ms over 250 units
DHCP Client
Port Base VLAN
LLDP (Link Layer Discovery Protocol)
Port configuration, status, statistics, monitoring, security
SNMP v1/v2c/v3 and private MIB support