background image

 

IES-2060  & IES-242FX-MM/SS  SERIES  User  Manual 

 

ORing Industrial Networking Corp 

34 

 

System Warning – Event Selection interface 

 

The following table describes the labels in this screen.

 

Label 

Description 

System Event 

 

System Cold Start

 

Alert when system restart 

O-Ring Topology Change 

Alert when O-Ring topology change   

Port Event 

 

Disable

   

 

Link Up

   

 

Link Down

   

 

Link Up & Link Down

   

Apply 

Click “

Apply

” to activate the configurations. 

Help 

Show help file. 

5.1.7.5

 

Fault Relay Alarm 

When any selected fault event is happened, the Fault LED in switch panel will light up and the 
electric relay will signal at the same time.   

 

Содержание IES-2060 Series

Страница 1: ...SE ER RI IE ES S I In nd du us st tr ri ia al l L Li it te e M Ma an na ag ge ed d E Et th he er rn ne et t S Sw wi it tc ch h U Us se er r M Ma an nu ua al l V Ve er rs si io on n 2 2 4 4 J Ja an n...

Страница 2: ...period with shipment expenses apportioned by ORing and the distributor This warranty does not cover product modifications or repairs done by persons other than ORing approved personnel and this warran...

Страница 3: ...n 5 Hardware Overview 6 3 1 Front Panel 6 3 2 Front Panel LEDs 6 3 3 Bottom Panel 7 Cables 8 4 1 Ethernet Cables 8 4 1 1 100BASE TX 10BASE T Pin Assignments 8 4 2 Fibers 9 WEB Management 10 5 1 Config...

Страница 4: ...figuration Port Based 26 5 1 6 SNMP Configuration 26 5 1 6 1 SNMP Agent Setting 27 5 1 6 2 SNMP Trap Setting 27 5 1 6 3 SNMP SNMP V3 Setting 29 5 1 7 System Warning 31 5 1 7 1 Syslog Setting 31 5 1 7...

Страница 5: ...management software With its friendly and powerful interface you can easily configure multiple switches at the same time and monitor switches status 1 2 Software Features World s fastest Redundant Eth...

Страница 6: ...on rear panel The DIN Rail kit helps switch to fix on the DIN Rail It is easy to install the switch on the DIN Rail 2 1 1 Mount IES 2042 SERIES on DIN Rail 2 2 Wall Mounting Installation Each switch h...

Страница 7: ...support auto negotiation Default Setting Speed auto Duplex auto Flow control disable Fiber port 100BaseFX for IES 2042FX switch Reset Push reset button 2 to 3 seconds to reset the switch Push reset bu...

Страница 8: ...il 10 100Base T X Fast Ethernet ports LNK ACT Green On Port link up Blinking Data transmitted LINK Amber On Port link up 100Base FX Fiber ports LNK ACT Green On Port link up Blinking Data transmitted...

Страница 9: ...Type Max Length Connector 10BASE T Cat 3 4 5 100 ohm UTP 100 m 328 ft RJ 45 100BASE TX Cat 5 100 ohm UTP UTP 100 m 328 ft RJ 45 4 1 1 100BASE TX 10BASE T Pin Assignments With 100BASE TX 10BASE T cable...

Страница 10: ...6 RD receive TD transmit 7 Not used Not used 8 Not used Not used Note and signs represent the polarity of the wires that make up each wire pair 4 2 Fibers The following two models IES 2042FX MM IES 2...

Страница 11: ...eb Based Management function supports Internet Explorer 5 0 or later It is based on Java Applets with an aim to reduce network bandwidth consumption enhance access speed and present an easy viewing sc...

Страница 12: ...Industrial Networking Corp 11 3 The login screen appears 4 Key in the username and password The default username and password is admin 5 Click Enter or OK button then the main interface of the Web bas...

Страница 13: ...of switch System Location Assign the switch physical location The maximum length is 64 bytes System Contact Enter the name of contact person or organization Firmware Version Display the switch s firm...

Страница 14: ...on DHCP Client To enable or disable the DHCP client function When DHCP client function is enabling the switch will assign the IP address from the network DHCP server The default IP address will be rep...

Страница 15: ...Configuration The SNTP Simple Network Time Protocol settings allow you to synchronize switch clocks in the Internet SNTP Configuration interface The following table describes the labels in this scree...

Страница 16: ...dard PDT Pacific Daylight 7 hours 5 am PST Pacific Standard ADT Alaskan Daylight 8 hours 4 am ALA Alaskan Standard 9 hours 3 am HAW Hawaiian Standard 10 hours 2 am Nome Alaska 11 hours 1 am CET Centra...

Страница 17: ...beginning time and Daylight Saving ending time Both will be different each year Daylight Saving Offset Set up the offset time Switch Timer Display the switch current time Apply Click Apply to activat...

Страница 18: ...abels in this screen Label Description TFTP Server IP Address Fill in the TFTP server IP Restore File Name Fill the file name Restore Click restore to restore the configurations Restore File Name Fill...

Страница 19: ...edundant links Fast Recovery mode supports 4 priorities only the first priority will be the act port the other ports configured with other priority will be the backup ports Fast Recovery Mode interfac...

Страница 20: ...escription O Ring Mark to enable O Ring Ring Master There should be one and only one Ring Master in a ring However if there are two or more switches which set Ring Master to enable the switch with the...

Страница 21: ...O Chain O Chain is the revolutionary network redundancy technology that provides the add on network redundancy topology for any backbone network providing ease of use while maximizing fault recovery s...

Страница 22: ...TP is an evolution of the Spanning Tree Protocol It provides faster spanning tree convergence after a topology change The system also supports STP and the system will auto detect the connected device...

Страница 23: ...he bridge with the lowest value has the highest priority and is selected as the root If the value changes you must reboot the switch The value must be multiple of 4096 according to the protocol standa...

Страница 24: ...n only be connected to exactly one other bridge i e It is served by a point to point LAN segment or it can be connected to two or more bridges i e It is served by a shared medium LAN segment This func...

Страница 25: ...ser Manual ORing Industrial Networking Corp 24 RSTP Information interface 5 1 4 Port Configuration 5 1 4 1 Port Control By this function you can set the state speed duplex flow control and security of...

Страница 26: ...lex You can set Auto negotiation 100 full 100 half 10 full 10 half mode Flow Control Support symmetric and asymmetric mode to avoid packet loss when congestion occurred Apply Click Apply to activate t...

Страница 27: ...VLAN Configuration Port Based Traffic is forwarded to the member ports of the same vlan group vlan port based startup set in the same group of the port can be a normal transmission packet without res...

Страница 28: ...en Label Description SNMP Agent Setting SNMP Community should be set for SNMP Four sets of Community String Privilege are supported Each Community String is maximum 32 characters Keep empty to remove...

Страница 29: ...interface The following table describes the labels in this screen Label Description Server IP The server IP address to receive Trap Community Community for authentication Trap Version Trap Version sup...

Страница 30: ...IES 2060 IES 242FX MM SS SERIES User Manual ORing Industrial Networking Corp 29 5 1 6 3 SNMP SNMP V3 Setting...

Страница 31: ...he user name that you have set up in user table 3 Group Name set up the group name 4 Click Add to add context name 5 Click Remove to remove unwanted context name Access Table 1 Configure SNMP v3 acces...

Страница 32: ...to switch panel 5 1 7 1 Syslog Setting The SYSLOG is a protocol to transmit event notification messages across networks Please refer to RFC 3164 The BSD SYSLOG Protocol System Warning SYSLOG Setting i...

Страница 33: ...nt log interface The following table describes the labels in this screen Label Description Page Select LOG page Reload To get the newest event logs and refresh this page Clear Clear log Help Show help...

Страница 34: ...Authentication Username the authentication username Password the authentication password Confirm Password re enter password Recipient E mail Address The recipient s E mail address It supports up to 6...

Страница 35: ...tem Event System Cold Start Alert when system restart O Ring Topology Change Alert when O Ring topology change Port Event Disable Link Up Link Down Link Up Link Down Apply Click Apply to activate the...

Страница 36: ...ion should be clicked to save current configuration data into the permanent flash memory Otherwise the current configuration will be lost when power off or system reset System Configuration interface...

Страница 37: ...36 Reset switch to default configuration Click Reset to reset all configurations to the default value You can select Keep current IP address setting and Keep current username password to prevent IP an...

Страница 38: ...et dB 7 5 db 19 db Technology Ethernet Standards IEEE 802 3 for 10Base T IEEE 802 3u for 100Base TX IEEE 802 3x forFlowcontrol IEEE 802 1D forSTP Spanning Tree Protocol IEEE 802 1w for RSTP Rapid Span...

Страница 39: ...VDC on7 pinterminal block 12 45VDC on power jack Power consumption Typ 6Watts 12VDC 0 48A 6W 24VDC 0 24A 6W 48VDC 0 14A 6W 7Watts 12VDC 0 55A 7W 24VDC 0 27A 6W 48VDC 0 16A 7W 6Watts 12VDC 0 48A 6W 24V...

Страница 40: ...IES 2060 IES 242FX MM SS SERIES User Manual ORing Industrial Networking Corp 39...