background image

IDS-5612 Series User’s Manual 

 

47 

 

ORing Industrial Networking Corp. 

 

Port Profile 
 

 

Figure 5-29 Port Profile 

 

The following table describes the labels in this screen.     

Label 

Description 

Serial to Ethernet   

Flush Data Buffer After: 

The received data will be queued in the buffer until all the delimiters are matched.   

When the buffer is full (4K Bytes) or after "

flush S2E data buffer

" timeout, the data will 

also be sent.    You can set the time from 0 to 65535 seconds.     

 

Delimiter: 

You can define max. 4 delimiters (00~FF, Hex) for each way.    The data will be hold until 

the delimiters are received or the option “

Flush Serial to Ethernet data buffer

” times 

out.  0 means disable.  Factory default is 0 

Содержание IDS-5612 Series

Страница 1: ...12 Series Version 1 0 May 2008 ORing Industrial Networking Corp 4F NO 3 Lane235 Baociao Rd Sindian City Taipei County 23145 Taiwan R O C Tel 886 2 2918 3036 Fax 886 2 2918 3084 Website www oring netwo...

Страница 2: ...12 on wall 5 HARDWARE OVERVIEW 8 3 1 Front Panel 8 3 2 Front Panel LEDS 9 3 3 Top Panel 10 3 4 Bottom Panel 10 3 5 Rear Panel 12 CABLES 13 4 1 Ethernet Cables 13 MANAGEMENT INTERFACE 15 5 1 DS Tool 15...

Страница 3: ...IDS 5612 Series User s Manual 5 2 1 4 Save Reboot 59 5 3 Configuration by SSH Console 60 5 3 1 Connect to DS 60 5 4 Configuration by Console Command 61 TECHNICAL SPECIFICATIONS 63...

Страница 4: ......

Страница 5: ...ly transfer data into 5 host PCs This feature can assure all critical data that saved in different host PC to avoid Ethernet break or host PCs failure IDS 5612 also Support the data encryption with SS...

Страница 6: ...erver TCP Client mode UDP Secured Management by HTTPS and SSH Serial console Management Console command Versatile Modes Virtual Com Serial Tunnel TCP Server TCP Client UDP Event Warning by Syslog Emai...

Страница 7: ...l IDS 5612 on DIN Rail Each IDS 5612 has a Din Rail kit on rear panel The Din Rail kit helps IDS 5612 to fix on the Din Rail It is easy to install the IDS 5612 on the Din Rail 2 1 1 Mount IDS 5612 on...

Страница 8: ...ush the IDS 5612 toward the Din Rail until you heard a click sound Figure 2 2 2 2 Wall Mounting Installation Each IDS 5612 has another installation method for you A wall mount panel can be found in th...

Страница 9: ...IDS 5612 Series User s Manual 5 ORing Industrial Networking Corp 2 2 1 Mount IDS 5612 on wall Step 1 Remove Din Rail kit Figure 2 3...

Страница 10: ...can be found in the package to combine the wall mount panel Just like the picture shows below Figure 2 4 The screws specification shows in the following two pictures In order to prevent IDS 5612 from...

Страница 11: ...IDS 5612 Series User s Manual 7 ORing Industrial Networking Corp Step 3 Mount the combined IDS 5612 on the wall Figure 2 6...

Страница 12: ...f IDS 5612 2 LED for PWR1 and system status When the PWR1 links the green led will be light on 3 LED for PWR2 and system status When the PWR2 links the green led will be light on 4 LED of 10 100Base T...

Страница 13: ...P or BOOTP server did not respond properly On DC power 2 activated PWR2 Green Red Red blinking Indicates an IP conflict or DHCP or BOOTP server did not respond properly Green Amber Green On Blinking 1...

Страница 14: ...panel components of IDS 5612 are showed as below 1 Terminal block include PWR1 12 48V DC 2 Power Jack include PWR2 12 48V DC 3 RJ45 Ethernet Connector 2 10 100Base T X Ethernet interface Figure 3 2 3...

Страница 15: ...RXD RXD 2 RXD RXD RXD 3 TXD TXD TXD DATA 4 DTR TXD TXD DATA 5 GND GND GND GND 6 DSR 7 RTS 8 CTS 9 RI RS 232 mod act as DTE Table 3 2 Pin assignment 3 DIP Switch Termination for RS 422 485 DIP 1 DIP 2...

Страница 16: ...anual ORing Industrial Networking Corp 12 3 5 Rear Panel The rear panel components of IDS 5612 are showed as below 1 Screw holes for wall mount kit and DIN Rail kit 2 Din Rail kit 3 Wall Mount kit Fig...

Страница 17: ...evice PCs servers switches routers or hubs Please refer to the following table for cable specifications Cable Type Max Length Connector 10BASE T Cat 3 4 5 100 ohm UTP 100 m 328 ft RJ 45 100BASE TX Cat...

Страница 18: ...t through cable to connect PC to IDS 5612 The following table below shows the 10BASE T 100BASE TX MDI and MDI X port pin outs Pin Number MDI port MDI X port 1 TD transmit RD receive 2 TD transmit RD r...

Страница 19: ...ndows utility for DS series It supports device discovery device configuration group setup group firmware update monitoring functions etc It is easy for you to install and configure devices over the ne...

Страница 20: ...IDS 5612 Series User s Manual ORing Industrial Networking Corp 16 Step 2 When installation complete successfully then click OK Figure 5 2 Step 3 Check for your selection Figure 5 3...

Страница 21: ...roadcast to the network and search all available DS devices in the network The default IP address of device is 192 168 10 2 and selects the searching device you wish to use and press Add button You ca...

Страница 22: ...NTP server and Auto IP Report Figure 5 5 General settings The following table describes the labels in this screen Label Description Device Name location You can set the device name or related informat...

Страница 23: ...eport its status periodically Table 5 1 General settings At IP collection option show the device server status The report interval is 0 indicate disable this setting default But you can set the other...

Страница 24: ...Network by wire You must assign a valid IP address for DS before attached in your network environment Your network administrator should provide you the IP address and related settings The IP address...

Страница 25: ...NS server The DNS server translates domain names into IP address Switch Mode Redundant When the connection between master link and LAN fails the DS can automatically switch to another LAN port within1...

Страница 26: ...Industrial Networking Corp 22 Figure 5 8 PPPoE Setting DDNS The Dynamic DNS service allows you to alias a dynamic IP address to a static hostname allowing your computer to be more easily accessed fro...

Страница 27: ...rvice Provider Choose the DDNS service Provider Hostname You must first apply an account from the DDNS service Provider such as www dyndns org then register with the dynamic DNS service Input the fixe...

Страница 28: ...istrator The events can be alarmed by E mail SNMP trap or system log Figure 5 11 Notification The following table describes the labels in this screen Label Description SNMP Trap To notify events by SN...

Страница 29: ...e 5 5 Notification Management Figure 5 11 Management The following table describes the labels in this screen Label Description Web Management Enable To enable management from Web Click Goto Web Manage...

Страница 30: ...by SNMP SNMP Management Settings To configure SNMP related settings Table 5 6 Management Upgrade Firmware Figure 5 12 Upgrade Firmware The following table describes the labels in this screen Label De...

Страница 31: ...iption Save Configuration to Flash Save current configuration into flash memory Load Default Load default configuration except the network settings If you want to load all factory default you need to...

Страница 32: ...anual ORing Industrial Networking Corp 28 Export Configuration Exported current configuration to a file to backup the configuration Table 5 8 Save Load 5 1 2 3 Configure serial port Serial Settings Fi...

Страница 33: ...l be hold until the delimiters are received or the option Flush Serial to Ethernet data buffer times out 0 means disable Factory default is 0 Flush Data Buffer After The received data will be queuing...

Страница 34: ...ns disable Factory default value is 0 Table 5 9 Serial settings Service Mode Virtual COM Mode In Virtual COM Mode The driver establishes a transparent connection between host and serial device by mapp...

Страница 35: ...the first host connection is effective for this setting Alive Check The serial device will send TCP alive check package in each defined time interval Alive Check to remote host to check the TCP conne...

Страница 36: ...fined period of time Idle Timeout the connection will be closed and the port will be freed and try to connect with other hosts 0 indicate disable this function Factory default value is 0 If Multilink...

Страница 37: ...lues is 1 Table 5 11 TCP Server mode Service Mode TCP Client Mode In TCP Client Mode device can establish a TCP connection with server by the method you have settled Startup or any character After the...

Страница 38: ...this function Factory default value is 0 If Multilink is configured only the first host connection is effective for this setting Alive Check The serial device will send TCP alive check package in eac...

Страница 39: ...aster and more efficient In UDP mode you can Uni cast or Multi cast data from the serial device server to host computers and the serial device can also receive data from one or multiple host Figure 5...

Страница 40: ...ipment is powered off A Notification will be sent RI changed When RI Ring Indicator signal changes it indicates that the incoming of a call A Notification will be sent CTS changed When CTS Clear To Se...

Страница 41: ...e trigger In Virtual COM Mode When Virtual COM is not available this event will be trigger A notification will be sent Table 5 13 Notification 5 2 Configuration by Web Browser 5 2 1 CONNECT TO THE WEB...

Страница 42: ...Manual ORing Industrial Networking Corp 38 Step 3 Input the name and password then click OK Figure 5 21 Certificate Only if password is set Step 4 The system information will be shown as below Figure...

Страница 43: ...can set the name of DS SNTP Enable the SNTP server Time zone After you set the SNTP enable select the time zone you located Time server Input SNTP server domain name or IP address and Port Console Tel...

Страница 44: ...ronment Your network administrator should provide you with the IP address and related settings The IP address must be unique and within the network otherwise DS will not have a valid connection to the...

Страница 45: ...tion option show the device server status The report interval is 0 indicate disable this setting default But you can set the other IP or Port Switch Mode Redundant When the connection between master l...

Страница 46: ...ial Networking Corp 42 Figure 5 24 PPPoE setting DDNS Configuration The Dynamic DNS service allows you to alias a dynamic IP address to a static hostname allowing your computer to be more easily acces...

Страница 47: ...der Hostname You must first apply an account from the DDNS service Provider such as www dyndns org then register with the dynamic DNS service Input the fixed hostname you got from the DDNS service Acc...

Страница 48: ...Industrial Networking Corp 44 Authentication You can set the password to prevent unauthorized access from network Input the Old password and New password to change the password Factory default is no...

Страница 49: ...gure 5 28 Serial configuration The following table describes the labels in this screen Label Description Port Alias Remark the port to hint the connected device Interface RS422 RS485 2 wires RS485 4 w...

Страница 50: ...X interval time is to specify the timeout when no data has been transmitted When the timeout is reached or TX buffer is full 4K Bytes the queued data will be sent 0 means disable Factory default value...

Страница 51: ...data will be queued in the buffer until all the delimiters are matched When the buffer is full 4K Bytes or after flush S2E data buffer timeout the data will also be sent You can set the time from 0 to...

Страница 52: ...00 FF Hex for each way The data will be hold until the delimiters are received or the option Flush Ethernet to Serial data buffer times out 0 means disable Factory default is 0 Table 5 18 Port Profil...

Страница 53: ...isable this function Factory default value is 0 If Multilink is configured only the first host connection is effective for this setting Alive Check The serial device will send TCP alive check package...

Страница 54: ...a TCP IP network In this case DS waits passively to be contacted by the device After the device establishes a connection with the serial device it can then proceed with data transmission TCP Server m...

Страница 55: ...effective for this setting Alive Check The serial device will send TCP alive check package in each defined time interval Alive Check to remote host to check the TCP connection If the TCP connection is...

Страница 56: ...d of time Idle Timeout the connection will be closed and the port will be freed and try to connect with other hosts 0 indicate disable this function Factory default value is 0 If Multilink is configur...

Страница 57: ...P Client will build TCP connection once the connected serial device starts to send data Table 5 21 TCP client mode Service Mode UDP Client Mode Compared to TCP communication UDP is faster and more eff...

Страница 58: ...e then the host will be allowed to access the DS You can choose one of the following cases by setting the parameter 1 Only one host with a special IP address can access the device server IP address 25...

Страница 59: ...IDS 5612 Series User s Manual 55 ORing Industrial Networking Corp Figure 5 34 Access IP...

Страница 60: ...our name and password There are 4 Email addresses that you can specify to receive the notification SNMP Server configuration includes the SNMP Trap Server IP address Community Location and Contact The...

Страница 61: ...he events can be alarmed by E mail SNMP trap or system log Figure 5 36 SMTP SNMP conf The following table describes the labels in this screen Label Description Hardware Reset Cold Start This refers to...

Страница 62: ...changed When DCD Data Carrier Detect signal changes it indicates that the modem connection status has been changed A Notification will be sent DSR changed When DSR Data Set Ready signal changes it ind...

Страница 63: ...n this screen Label Description Factory Default Load default configuration except settings of Network If you want load all factory default you should press Reset button about the five seconds on the d...

Страница 64: ...are with specified file Reboot Device Reboot the device server warm start Table 5 23 Save Reboot 5 3 Configuration by SSH Console 5 3 1 Connect to DS You can use SSH Tool e g PUTTY to access SSH conso...

Страница 65: ...rial port socket mode 0 TCP server 1 TCP client 2 UDP 3 VCOM SioMode Query serial port socket mode 0 TCP server 1 TCP client 2 UDP 3 VCOM SioPort port Set serial socket port SioPort Query serial socke...

Страница 66: ...nd return to data mode Update Save parameters to 93C46 permanently Refresh Synchronize device information Default Restore all settings to Factory default Reboot Reboot the device server OnLine Query i...

Страница 67: ...e 1x RS232 RS422 4 2 Wire RS485 Which can be configured by DS Tool Connector Male DB9 Serial Baud Rate 110 bps to 460 8 Kbps Data Bits 5 6 7 8 Parity odd even none mark space Stop Bits 1 1 5 2 RS 232...

Страница 68: ...ck PWR1 12 48VDC in 3 pin Terminal Block Reverse Polarity Protection Present at terminal block Power Consumption 4 Watts MAX Software Utility Utility DS Tool for Windows NT 2000 XP 2003 VISTA which in...

Страница 69: ...al Operating Temperature 10 to 60 C 14 to 140 F Operating Humidity 5 to 95 Non condensing Storage Temperature 20 to 85 C 4 to 185 F Mechanical Dimensions W x D x H 72mm W x125mm D x31mm H Casing IP 30...

Отзывы: