Introduction
PRINTED ON RECYCLED PAPER
Q I G
IBS-102FX Series
are external Bypass switches for 100M/1G/10G fiber
IBS-102FX series
optical networks. These fiber optical bypass switches protect the network
from failures and Network maintenance by ensuring network integrity during
power loss. Each of these optical bypass switches includes Network ports
and Monitor ports.
The Network ports are used for connection to main-
network connections and provide protection mechanism, and the Monitor
ports are used for down-link local networking device. When the power is on,
the operating mode of the Bypass switch is set to Normal , and the local
networking device is connected with main-network.
When power failure
occurs, the Bypass switch is swiftly set to bypass mode to isolate the main-
network from the local networking device.
Package Contents
Installation
The device is shipped with the following items. If any of these items is missing
or damaged, please contact your customer service representative for
assistance.
Contents
Wall-mount Kit
DIN-rail Kit
IBS-102FX-MM-LC or
IBS-102FX-SS-LC
Pictures
Number
X 2
X 1
QIG
X 1
X 1
Step 1:
Slant the switch and screw the Din-rail kit onto the back of the switch, right in the
middle of the back panel.
Step 2:
Slide the switch onto a DIN-rail from the Din-rail kit and make sure the switch clicks into
the rail firmly.
DIN-rail Installation
Step 1:
Screw the two pieces of wall-mount kits onto both sides of the switch. A
total of eight screws are required, as shown below.
Step 2:
Use the switch, with wall mount plates attached, as a guide to mark the correct
locations of the four screws.
Step 3:
Insert four screw heads through the large parts of the keyhole-shaped apertures, and
then slide the switch downwards. Tighten the four screws for added stability.
Wall-mounting
Features
Support 100M/1G/10G optical bypass function of 2 port duplex or 4 port simplex
fiber connection
Different models supported for multi-mode or single-mode optical fiber
Low insertions loss
Throughput not affected and no extra delay
Bypass switching time < 8ms
Dual Wide range power inputs: 12~48VDC
Relay output for pwer failed warning
Rigid IP-30 housing design
Din-Rail/Wall-mount installation
Preparation
Before you begin installing the switch, make sure you have all of the package
contents available.
Reduced Air Flow:
Installation of the equipment should be such that the amount of
air flow required for safe operation of the equipment is not compromised.
Mechanical Loading:
Mounting of the equipment in the d
should be such that
in-rail
a hazardous condition is not achieved due to uneven mechanical loading.
Circuit Overloading:
Consideration should be given to the connection of the equipment to
the supply circuit and the effect that overloading of the circuits might have on overcurrent
protection and supply wiring. Appropriate consideration of equipment nameplate ratings
should be used when addressing this concern.
Dimension
Panel Layouts
Front Panel
1. PWR1 LED
2. PWR2 LED
3. Fault LED
4. DIP-switch for power alarm
relay output
5. LC connector ports
3
1
4
Top Panel
1
2
4
1. Wall-mount screw
holes
2. Terminal block
3. DC power input
4. Frame ground
Real Panel
1
1. Din-rail screw holes
2
1
IBS-102FX Series
BYPASS
I N D U S T R I A L
SWITCH
Industrial Optical Bypass Switch
1907-2-29-IBS102FX-2.1
Elevated Operating Ambient:
If installed in a closed cabinet, the operating
ambient temperature of the rack environment may be greater than room ambient.
Therefore, consideration should be given to installing the equipment in an
environment compatible with the maximum ambient temperature (Tma) specified by
the manufacturer.
Safety & Warnings
6
8
.1
5
8
.0
14.0
6.05
25.0
5
0
.0
2
5
.5
26.1
1
4
4
.3
94.9
36.1
36.0
G
22.8
P1
P2 Fault
IBS -102FX
A
A
100M /1G /10G bps
N
e
tw
o
rk
B
TX
RX
B
TX
RX
TX
RX
TX
RX
M
o
n
it
o
r
Alarm
P1
P2
9.25
8.5
1
2
.3
13.1
24.3
25.6
2
4
.3
Ø5.9
Ø3.0
Unit =mm (Tolerance ±0.5mm)
5
G
PWR2
1A@24V
V+
V- DC12-48V
-
+
Relay
PWR1
3
P1
P2 Fault
IBS -102FX
A
A
100M /1G /10G bps
N
e
tw
o
rk
B
TX
RX
B
TX
RX
TX
RX
TX
RX
M
o
n
it
o
r
Alarm
P1
P2