11
3.3
Wiring
For pin assignments of the power connector, please refer to the following tables.
3.3.1 Power Supply
The device is powered by an Ethernet cable via the PoE port, which is on the right hand side.
Make sure the PoE port is connected with an RJ-45 cable and check if the power LED lights
up after connection.
3.3.2 Reset
For protection, the reset button is placed in the case covered by a screw head. If you need to
reset the device, remove the screw and use a very small point object like a needle or a
toothpick to poke the reset button. To reboot the device, press the Reset button for 5
seconds.To restore the device configurations back to the factory defaults, press the Reset
button for 3 seconds.