Method of control via Modbus protocol
−29−
Parameter R/W commands [Data setter]
Register address
Name
Description
Setting range
Initial
value Update
*
Dec
Hex
960
03C0h Data setter speed
display (upper)
Sets the display method
of operating speed in the
monitor mode. If "0" is set, "-"
will be displayed when the
motor rotates in the reverse
direction.
0: Signed
1: Absolute value
0
A
961
03C1h Data setter speed
display (lower)
962
03C2h Data setter edit
(upper)
Switches whether to enable
or disable the following
editing functions.
•
Clear of the alarm and
warning histories in the
monitor mode
•
Change of the setting
value in the data mode and
parameter mode
•
All operation in the copy
mode
0: Disable
1: Enable
1
D
963
03C3h Data setter edit
(lower)
4320
10E0h Data setter initial
display (upper)
Selects the initial screen when
the power is supplied to the
BLV
Series driver.
0: Rotation speed
1: Conveyor transfer speed
2: Load factor
3: Operation data number
4: Top screen of monitor mode
0
4321
10E1h Data setter initial
display (lower)
*
It indicates the timing for the data to update.
A: Update immediately, D: Update after turning on the power again
Parameter R/W commands [I/O function (Direct I/O)]
Register address
Name
Setting range
Initial value Update
*1
Dec
Hex
4352
1100h X0 input function selection (upper)
0: Not used
1: FWD (START/STOP)
*2
2: REV (RUN/BRAKE)
*2
19: STOP-MODE (FWD/REV)
*2
20: MB-FREE
21: EXT-ERROR
24: ALARM-RESET
27: HMI
48: M0
49: M1
50: M2
1
B
4353
1101h X0 input function selection (lower)
4354
1102h X1 input function selection (upper)
2
4355
1103h X1 input function selection (lower)
4356
1104h X2 input function selection (upper)
19
4357
1105h X2 input function selection (lower)
4358
1106h X3 input function selection (upper)
48
4359
1107h X3 input function selection (lower)
4360
1108h X4 input function selection (upper)
24
4361
1109h X4 input function selection (lower)
4362
110Ah X5 input function selection (upper)
20
4363
110Bh X5 input function selection (lower)
4416
1140h Y0 output function selection (upper)
0: Not used
65: ALARM-OUT1
66: WNG
68: MOVE
71: TLC
77: VA
81: ALARM-OUT2
84: DIR
65
A
4417
1141h Y0 output function selection (lower)
4418
1142h Y1 output function selection (upper)
66
4419
1143h Y1 output function selection (lower)
*1
It indicates the timing for the data to update.
A: Update immediately, B: Update after operation stop
*2
The parentheses ( ) will be applied when the "3-wire input mode" is selected with the "Operation input mode selection"
parameter.