Guidance
14
6
Guidance
If you are new to the
NETC01-M2
, read this section to understand the operating methods along with the operation
flow.
As an example, this chapter explains how to perform positioning operation for the “
CRK
Series FLEX Built-in controller
type [described as the
CRD-KD
in this manual],” using the
NETC01-M2
via MECHATROLINK-II communication.
•
Before operating the motor, check the condition of the surrounding area to ensure safety.
•
Refer to “13-8 Parameter mode” on p.51 for how to set parameters.
STEP 1
Set the transmission rate, station address and address number
Using the parameter
1. Set the “Connection (address number 0)” parameter of the
NETC01-M2
to “1: Enable.”
2. Cycle the
NETC01-M2
power.
•
“Connection” parameters will be enabled after the power is cycled.
•
When setting the parameters of the
NETC01-M2
, use the
MEXE02
or
OPX-2A
.
Using the switches
z
Setting condition of
CRD-KD
•
Address number of
CRD-KD
: 0
•
Connection device of
CRD-KD
: Network converter
z
Setting condition of
NETC01-M2
•
MECHATROLINK-II station address: 61h
•
RS-485 transmission rate: 625 kbps
•
Remote I/O occupied size: 16 bit mode
•
Number of transmission bytes: 32 bytes
Connection device:
Network converter
CRD-KD
address
number: 0
×10: 6
×1: 1
NETC01-M2
CRD-KD
SW4: OFF
SW1 to 3: ON
MECHATROLINK-II
station address: 61h
SW2-No.1: OFF
Remote I/O occupied size:
16 bit mode
SW2-No.2: OFF
SW2-No.3: ON
Number of transmission
bytes: 32 bytes
SW1: 7
SW1: 0
RS-485 transmission
rate: 625 kbps