Connection
13
5-4
Connecting the MECHATROLINK-II communication
Connect the MECHATROLINK-II communication cable to the
MECHATROLINK-II communication connector (CN2-1 or CN2-2) of
the
NETC01-M2
. For the MECHATROLINK-II communication cable,
use a dedicated cable with connector.
Other MECHATROLINK-II communication compatible products can
be connected to the vacant connector.
Connect a termination resistor to the
NETC01-M2
that is
positioned at the end from the master device.
MECHATROLINK-II
communication connector
(CN2-1)
MECHATROLINK-II
communication cable
5-5
Connecting the data setter
Connect the communication cable for the support software
or
OPX-2A
cable to the data edit connector (CN3) on the
NETC01-M2
.
Data edit connector (CN3)
Communication cable for the
support software or
OPX-2A
cable
The power supply connector (CN1), MECHATROLINK-II communication connectors
(CN2-1, CN2-2), data edit connector (CN3) and RS-485 communication connector
(CN6) of the
NETC01-M2
are not electrically insulated. When grounding the positive
terminal of the power supply, do not connect any equipment (PC, etc.) whose
negative terminal is grounded. Doing so may cause the
NETC01-M2
and these
equipment to short, damaging both.