background image

5

Regulations and standards

„

„

UL Standards, CSA Standards, CCC System

This product is recognized by UL under the UL and CSA Standards, and also 

certified by CQC under the China Compulsory Certification (CCC) system.

The motor model name represents the model that conforms to the standards.

 

z

Applicable standards

Applicable standards

Certification Body / File No.

UL 1004-1, UL 1004-2, UL 1004-3

UL /

UL File No.E64197, E64199

CSA C22.2 No.100, CSA C22.2 No.77
GB 12350

CQC

 

Thermal Class: 130 (B)

 

z

Standards for accessories

 

Capacitor: UL File No.E83671 (CYWT2), 

VDE License No.112847 (capacitors with a rated voltage of 250 VAC), 

114747 (capacitors with a rated voltage of 450 VAC)

 

Capacitor cap: UL File No.E56078 (YDTU2)

„

„

CE Marking

This product is affixed the CE Marking under the Low Voltage Directive.

 

z

Low Voltage Directive

Applicable standards

EN 60034-1, EN 60034-5, EN 60664-1
Momentary excess torque based on EN 60034-1

Model Momentary excess torque

Momentary excess torque represents 

a maximum torque that can maintain 

the operation for 15 seconds without 

stalling or abrupt speed change even 

if the torque is increased gently while 

operating at rated voltage and rated 

frequency.

2RK6 
3RK15

130% of the rated torque

4RK25 
5RK40 
5RK60

160% of the rated torque

5RK90

140% of the rated torque

Installation conditions 

(For EN standard)

Overvoltage category

, Pollution degree 2, Class

equipment

When the machinery to which the motor is mounted requires overvoltage 

category

specifications, install the motor in a cabinet that connect to power 

supply via an isolation transformer.

Motor temperature rise tests

Temperature rise tests required by the above standards are performed in a state 

that has been attached a heat radiation plate instead of a gearhead.

The size and material for the heat radiation plates are as follows.

[Size]

2RK6

: 115×115 mm (4.53×4.53 in.) 

3RK15

: 125×125 mm (4.92×4.92 in.)

4RK25

: 135×135 mm (5.31×5.31 in.) 

5RK40

: 165×165 mm (6.50×6.50 in.)

5RK60

5RK90

: 200×200 mm (7.87×7.87 in.)

[Thickness] 5 mm (0.20 in.)

[Material] Aluminum alloy

„

„

Hazardous substances

The products do not contain the substances exceeding the restriction values of 

RoHS Directive (2011/65/EU).

Содержание KII Series

Страница 1: ...z o z z 2RK6 M o 2RK6GV M 2GVoB IP20 3RK15 M o 3RK15GV M 3GVoB 4RK25 M o 4RK25GV M 4GVoB 5RK40 M o 5RK40GV M 5GVoB IP40 5RK60 M o 5RK60GVH M 5GVHoB IP20 5RK90 M o 5RK90GVR M 5GVRoB 5RK40 MT2 o 5RK40GV...

Страница 2: ...25 60 12 30 120 65 12 150 360 70 12 4RK25 2 3 65 9 5 25 60 9 30 120 65 9 150 360 70 9 5RK40 5RK60 2 3 M8 85 16 12 0 5 18 70 14 25 100 85 16 120 300 90 15 5RK90 3 85 16 5 15 70 14 18 36 85 16 50 180 9...

Страница 3: ...25 30 36 50 60 75 90 100 120 150 180 250 300 5RK90 3 5 6 7 5 9 12 5 15 18 25 30 36 50 60 75 90 100 120 150 180 CW Z2 U2 U1 MB MB R0 C0 SW2 CCW CW N R0 C0 L SW1 R0 C0 R0 C0 R0 C0 SW2 SW1 SW2 100 110 11...

Страница 4: ...0 180 M4 4 1 0 1 5 N m 5RK 180 1 M3 2 180 3 0 5 0 7 N m 90 C 90 C SW1 SW2 3 SW2 CCW CW OFF ON ON OFF OFF CW CW CCW SW1 SW1 SW1 ON SW1 OFF SW2 CW CCW z z 10 ms z z 2 30 30 30 min 2 TP 130 5 C 85 20 C Z...

Страница 5: ...CQC 130 B z z UL File No E83671 CYWT2 VDE License No 112847 250 VAC 114747 450 VAC UL File No E56078 YDTU2 CE CE z z EN 60034 1 EN 60034 5 EN 60664 1 EN 60034 1 15 2RK6 3RK15 130 4RK25 5RK40 5RK60 160...

Страница 6: ...6 Copyright ORIENTAL MOTOR CO LTD 2015 2017 2...

Страница 7: ...mage to equipment Do not touch the connection terminal of the capacitor immediately after the power is turned off for a period of 30 seconds The residual voltage may cause electric shock Do not disass...

Страница 8: ...55 Removing Installing the gearhead See the following steps to replace the gearhead or to change the outlet position of the lead wires and the position of the terminal box Removing the gearhead from t...

Страница 9: ...the terminal box type Contact capacity of SW1 and SW2 Model Input specification Single phase 100 110 115 V Single phase 200 220 230 V 2RK 3RK 4RK 125 VAC 3 A or more Inductive load 250 VAC 1 5 A or m...

Страница 10: ...wise CW direction switch SW2 to CW To rotate it in a counter clockwise CCW direction switch SW2 to CCW Other ways of operating z z Shortening the motor s starting time If the electromagnetic brake is...

Страница 11: ...nts a maximum torque that can maintain the operation for 15 seconds without stalling or abrupt speed change even if the torque is increased gently while operating at rated voltage and rated frequency...

Страница 12: ...February 2017 Technical Support Tel 800 468 3982 8 30 A M to 5 00 P M P S T M F 7 30 A M to 5 00 P M C S T M F www orientalmotor com Schiessstra e 74 40549 D sseldorf Germany Technical Support Tel 00...

Отзывы: