Operation I/O event R/W commands
4 P
ar
78
5
Operation I/O event R/W commands
If a specified event (ON/OFF of I/O) is generated during operation of the motor, another operation can be started. This
is called operation I/O event. This chapter explains the address to execute the operation I/O event.
5-1
Base address of operation I/O event
Base address
Operation I/O
event number
Dec
Hex
2560
0A00h
0
2568
0A08h
1
2576
0A10h
2
2584
0A18h
3
2592
0A20h
4
2600
0A28h
5
2608
0A30h
6
2616
0A38h
7
2624
0A40h
8
2632
0A48h
9
2640
0A50h
10
Base address
Operation I/O
event number
Dec
Hex
2648
0A58h
11
2656
0A60h
12
2664
0A68h
13
2672
0A70h
14
2680
0A78h
15
2688
0A80h
16
2696
0A88h
17
2704
0A90h
18
2712
0A98h
19
2720
0AA0h
20
2728
0AA8h
21
Base address
Operation I/O
event number
Dec
Hex
2736
0AB0h
22
2744
0AB8h
23
2752
0AC0h
24
2760
0AC8h
25
2768
0AD0h
26
2776
0AD8h
27
2784
0AE0h
28
2792
0AE8h
29
2800
0AF0h
30
2808
0AF8h
31
5-2
Parameter ID for operation I/O event R/W command
The setting item of operation I/O event is set with the operation I/O event R/W command.
The parameter ID for the setting item is arranged based on the base address of the operation I/O event.
For example, in the case of the setting item “Dwell,” 2 is added to the base address.
Parameter ID
Name
Setting range
Initial value
Update
Base a0
Link
0: No link
1: Manual sequential
2: Automatic sequential
3: Continuous sequential operation
0
B
Base a1
Next data number
−256: Stop
−2:
↓↓
(+2)
−1:
↓
(+1)
0 to 255: Operation data number
−256
B
Base a2
Dwell
0 to 65,535 (1=0.001 s)
0
B
Base a3
Event trigger I/O
Input signal list
_
Output signal list
0: No function
B
Base a4
Event trigger type
0: Non
1: ON (calculated cumulative ms)
2: ON (ms)
3: OFF (calculated cumulative ms)
4: OFF (ms)
5: ON edge
6: OFF edge
7: ON (cumulative ms)
8: OFF (cumulative ms)
0
B
Base a5
Event trigger counter
0 to 65,535 (1=1 ms or 1=once)
0
B