TECHNICAL DATA
36
Version 2.1
5.1.4
Aeronautical obstruction light L85EX-R-AC-32
Explosion proof LED aeronautical obstruction light.
/i
Table 13
Standards and certification
/i
Table 14
Performance characteristics
/i
Table 15
Electrical characteristics
/i
Table 16
Physical characteristics
Standards/Certification
Certified to ICAO Annex 14, volume l; : Aerodrome design and
operation, 6th Edition, 2013, chapter 6.3.2 - Type B low intensity
obstacle light
Certified to IMO standard, MODU code 2009 (Edition 2010) , chap-
ter 13.5.24
Cenelec EN 60079-0, EN 60079-7 and EN 60079-18
SIRA 12ATEX3066 X; ATEX
II 2G Ex e mb IIC T4 Gb
IEC 60079-0, IEC 60079-7 and IEC 60079-18
IECEx SIR 12.0026 X; Ex e mb IIC T4 Gb
NCC 12.1223; Ex e mb IIC T4 Gb
LED
Steady burning; red
Intensity
Minimum 32 cd
Horizontal beam coverage
360º
Vertical beam profile
As per ICAO
Colour chromaticity
Within the boundaries as specified by ICAO
Light source
LED (100,000 hours average life)
Operating voltage
100-254 Vac; 50-60 Hz
Power consumption
Approx. 5.5 W (7 VA)
Connection details
M4; two M25x1.5 cable entries
Earth connection
Internal M4 and external M6
Dimensions (L x W x H)
161 x 161 x 111 mm
Weight
3.6 kg
Degree of protection
IP66
Operating temperature range
ATEX/IECEx
-40 ºC to +60 ºC
Operating temperature range
Inmetro
-50 ºC to +45 ºC
Содержание L85EX
Страница 14: ...DESCRIPTION 14 Version 2 1...
Страница 22: ...INSTALLATION 22 Version 2 1...
Страница 26: ...MAINTENANCE 26 Version 2 1...
Страница 30: ...TROUBLESHOOTING 30 Version 2 1...
Страница 59: ...Version 2 1 59 C IECEx CERTIFICATE C 1 IECEx Certificate of Conformity L85EX...
Страница 60: ...60 Version 2 1...
Страница 61: ...Version 2 1 61...
Страница 62: ...62 Version 2 1...
Страница 63: ...Version 2 1 63...
Страница 64: ...64 Version 2 1...
Страница 66: ...66 Version 2 1...