orfit RAYCAST 38227 Скачать руководство пользователя страница 1

 

Page 1 of 2 

 

INSTRUCTIONS FOR USE  

 

 

RAYCAST

®

HIGH PRECISION 

BASE PLATE-TO-COUCH 
TOP FIXATION DEVICES  

AIO 3.0 LATERAL FIXATION 
DEVICES NON-INDEXED 
530MM FOR 530MM WIDE 
BASE PLATES 

 
Article Nos. : 

38227

 

A.

 

GENERAL PRODUCT INFORMATION 

This product is a lateral fixation device to attach the AIO 3.0 
base plates with a width of 530mm to (non-indexed) 

couch tops 

with a width of  530mm

.  

B.

 

PRODUCT DESCRIPTION 

This fixation device features two positioning blocks that can be 
attached on both sides of the AIO 3.0 base plate that have a 
width of 530 mm (#38009). This fixation device is specifically 
designed to fix the baseplates 

laterally

 

on any treatment couch 

with a width of

 

530mm

. To obtain a highly reproducible patient 

position, it is required to use 2 sets (1 set at the cranial position 
and 1 set at the caudal position) or 1 set cranially in 
combination with an indexing bar at the caudal end of the base 
plate. 
Information on these other parts can be found in the respective 

‘Instructions for Use’

 and o

www.orfit.com

.  

 
Parts list: 

Ref. No. 

Description 

38227/1 

AIO 3.0 Lateral Fixation, 500 mm 

32317/2/13 

M6 x 20 Screw 

 

C.

 

INSTRUCTIONS FOR USE 

The blocks of this lateral fixation device have a circular recess 
on the inside that fits over the bulbs of the Prodigy

™ and 

Pinpoint™ style indexing systems. 

 

 
Mount the indexing

 

blocks to the side of the base plate using 

the plastic countersunk M6 x 20 screws. You will need a Philips-
head screwdriver to turn the screws. Do not excessively tighten 
the screws as they are made out of plastic.  

 

 

Bottom view 

It is possible to use 2 sets of these fixation devices on the AIO 
3.0 base plates for lateral fixation on any 530mm wide couch 
top. See picture below. 

Never do this when the baseplate is 

hanging over the edge of the couch.

 

 

 

 

 

 
 
For indexed couches, always use a set of the AIO 3.0 Lateral 
Fixation Device (or an additional secondary set)  in combination 
with a 2-pin bar at the caudal end to ensure a longitudinal 
fixation. See picture below. 
 

 

 
 
 

D.

 

PRECAUTIONS FOR USE 

Do not use the lateral fixation devices on its own when the base 
plate is in overhang off the couch top! The lateral fixation 
devices do not provide a safe fixation for base plates in 
overhang situations. 
 
Make sure the screws are tightened so there is no play of the 
base plate during setup and treatment. Ensure the lateral 
fixation devices are not overhanging the couch laterally.  
 
The plastic screws can be damaged if excessive force is used 
during assembly with a screwdriver.  
 

E.

 

STORAGE 

Always  store  the  products  in  a  safe  place  to  prevent  it  from 
getting damaged. 
Store the product b10°C (50°F) and 40°C (122°F). 

 