background image

THE  RESET  BUTTON

See the user manual of your main unit for further information.

This button is only used when the unit is operating in an unfavorable
way or malfunctioning. Use a blunt stylus to hold down the button. All
settings will return to their default values.

HOW  TO  USE  THE  TABLE  STAND  OR  WALL
MOUNT

This sensor comes with a wall-mount holder and a removable stand.
Use either to set up the unit.

PRECAUTIONS

This product is engineered to give you years of satisfactory service if
you handle it carefully. Here are a few precautions:

1. Do not immerse the unit in water.

2. Do not clean the unit with abrasive or corrosive materials. They

may scratch the plastic parts and corrode the electronic circuit.

3. Do not subject the unit to excessive force, shock, dust, temperature

or humidity, which may result in malfunction, shorter electronic life
span, damaged battery and distorted parts.

4. Do not tamper with the unit’s internal components. Doing so will

invalidate the warranty on the unit and may cause unnecessary
damage. The unit contains no user-serviceable parts.

5. Only use fresh batteries as specified in the user manual. Do not

mix new and old batteries as the old ones may leak.

6. Always read the user manual thoroughly before operating the unit.

SPECIFICATIONS

Temperature Measurement

Displayed range

: -58.0

°

F to 158.0

°

F

(-50.0

°

C to +70.0

°

C)

Proposed operating  range

: -22 

°

F to 140 

°

F

(-30 

°

C to 60 

°

C)

Temperature resolution

: 0.2

°

F  (0.1

°

C)

RF Transmission Frequency

: 433 MHz

No. of  Remote unit

: Maximum of 3

RF Transmission Range

: Maximum 98 feet (30 meters)

Temperature sensing cycle

: around 30 seconds

Power

:  use 2 pcs UM-3 or “AA”

1.5V alkaline batteries

Weight

: 3.5 ounces (110 grams)

Dimension

: 4 x 2.7 x 0.8 inches (103 x 68 x

21 mm)

CAUTION

The content of this manual is subject to change without
further notice.

Due  to  printing  limitations,  the  displays  shown  in  this
manual may differ from the actual display.

The  manufacturer  and  its  suppliers  hold  no
responsibility to you or any other person for any damage
expenses,  lost  profits,  or  any  other  claim  as  a  result  of
using this product.

The  contents  of  this  manual  may  not  be  reproduced
without the permission of the manufacturer.

 

 

ENGLISH

USER  MANUAL

INTRODUCTION

Congratulations on purchasing the THC-138 Remote Thermo Sensor.

The Remote Thermo Sensor is used with the 433MHz Multi-Channel
In-Out  Thermometer  (Model:  EMR812,  EMR899,  RMR112  or
BAR888)  to  monitor  temperature  changes  of  remote  or  outdoor
sites.  Operation is easy and no wire installation is required.

MAIN  FEATURES:

LCD

Displays the current temperature monitored by the remote unit
and indicates the selected channel

LED INDICATOR

Flashes when the remote unit transmits a reading

TEMPERATURE SENSOR PROBE

On 10 feet (3 meter) cable

°

C/

°

F SLIDE SWITCH

Selects between Centigrade (

°

C) and Fahrenheit (

°

F)

CHANNEL SLIDE SWITCH

Designates the remote unit Channel 1, Channel 2 or Channel 3

RESET BUTTON

Returns all settings to default values

BATTERY COMPARTMENT

Accommodates two AA-size batteries

BATTERY DOOR

WALL-MOUNT HOLDER

Supports the remote unit in wall-mounting

REMOVABLE TABLE STAND

For standing the remote unit on a flat surface

BEFORE  YOU  BEGIN

For best operation,

1. Assign different channels to different remote units.

2. Insert  batteries  for  remote  units  before  doing  so  for  the  main  unit.

(Main unit of model EMR899, EMR-899, RMR-112 or BAR-888)

3. Place the main unit as close as possible next to the remote unit, and

reset the main unit after installing batteries. This will ensure easier
synchronization between the transmission and reception of signals.

4. Position the remote unit and main unit within effective transmission

range,  which,  in  usual  circumstances,  is  66  to  98  feet  (20  to  30
meters).

Note that the effective range is vastly affected by the building materials
and where the main and remote units are positioned. Try various set-
ups for best result.

Though the sensor is weather proof and meant to be used outdoors,
it should be placed away from direct sunlight, rain or snow.

BATTERY  AND  CHANNEL  INSTALLATION

The remote unit uses two AA-size batteries. To install them,

1. Remove the screws on the battery compartment.

2. Select the channel number on the CHANNEL slide switch.

3. Select the temperature display unit on the 

°

C/

°

F slide switch.

4. Insert the batteries strictly according to the polarities shown inside.

5. Replace the battery compartment door and secure its screws.

Standard Alkaline batteries contain signifcant amounts of water. Because
of  this  they  will  freeze  in  low  temperatures  of  approximately  10

°

F.

Disposable Lithium batteries have a much lower threshold for temperature
with  an  estimated  freezing  range  of  below  -40

°

F.  The  Liquid  Crystal

Display  in  outdoor  thermometers  will  remain  operational  to  -20

°

F  with

adequate power.

Wireless ranges can be impacted by a variety of factors such as extremely
cold  temperatures.  Extreme  cold  may  temporarily  reduce  the  effective
range between the sensor and the base station. If the unit's performance
fails due to low temperature, the unit will resume proper functioning as the
temperature rises to within the normal temperature range (i.e no permanent
damage will occur to the unit due to low temperatures).

CHANGE  CHANNEL

Once  a  channel  is  assigned  to  a  unit,  you  can  only  change  it  by
removing the batteries and repeating the above procedure.

LOW-BATTERY  WARNING

Replace the batteries of the sensor when the low-battery indicator of
the channel represented by the sensor shows up on the main unit.

OPERATION

Once batteries are in place, the sensor will start transmitting samplings
at 30-second intervals.

The current temperature will be shown on the LCD in the selected
unit (

°

C/

°

F) at the designated channel. The unit (

°

C/

°

F) shown on the

main unit is determined by the setting on the main unit.

HOW  TO  INSTALL  THE  TEMPERATURE
SENSING  CABLE

Secure the sensor to an area you want to monitor.  Do not expose it
to direct sunlight.

MULTI-CHANNEL

CABLE  FREE

REMOTE  THERMO  SENSOR

MODEL:  THC138

© 2004 Oregon Scientific. All Rights Reserved.

086-002026-xxx

ABOUT  OREGON  SCIENTIFIC

Visit  our  website  (www.oregonscientific.com)  to  learn  more  about
Oregon  Scientific  products  such  as  digital  cameras;  MP3  players;
children’s electronic learning products and games; projection clocks;
health and fitness gear; weather stations; and digital and conference
phones.  The  website  also  includes  contact  information  for  our
customer care department in case you need to reach us, as well as
frequently asked questions and customer downloads.

We hope you will find all the information you need on our website,
however if you’d like to contact the Oregon Scientific Customer Care
department directly, please visit:
www2.oregonscientific.com/service/support

OR

Call 949-608-2848 in the US.

For international enquiries, please visit:
http://www2.oregonscientific.com/about/international/default.asp

FCC  STATEMENT

This  device  complies  with  Part  15  of  the  FCC  Rules.  Operation  is
subject  to  the  following  two  conditions:  (1)  This  device  may  not
cause  harmful  interference,  and  (2)  This  device  must  accept  any
interference received, including interference that may cause undesired
operation.

WARNING

  Changes  or  modifications  to  this  unit  not  expressly

approved  by  the  party  responsible  for  compliance  could  void  the
user’s authority to operate the equipment.

NOTE

 This equipment has been tested and found to comply with the

limits  for  a  Class  B  digital  device,  pursuant  to  Part  15  of  the  FCC
Rules.  These  limits  are  designed  to  provide  reasonable  protection
against harmful interference in a residential installation.

This  equipment  generates,  uses  and  can  radiate  radio  frequency
energy  and,  if  not  installed  and  used  in  accordance  with  the
instructions, may cause harmful interference to radio communications.
However, there is no guarantee that interference will not occur in a
particular  installation.  If  this  equipment  does  cause  harmful
interference to radio or television reception, which can be determined
by turning the equipment off and on, the user is encouraged to try to
correct the interference by one or more of the following measures:

Reorient or relocate the receiving antenna.

Increase the separation between the equipment and receiver.

Connect  the  equipment  into  an  outlet  on  a  circuit  different  from
that to which the receiver is connected.

Consult  the  dealer  or  an  experienced  radio  /  TV  technician  for
help.

DECLARATION OF CONFORMITY

The following information is not to be used as contact for support or
sales. Please call our customer service number (listed on our website
at www.oregonscientific.com), or on the warranty card for this product)
for all inquiries instead.

We

Name:

Oregon Scientific, Inc.

Address:

19861 SW 95th Place, Tualatin, Oregon 97062

USA
Telephone No.: 1-800-853-8883
Fax No.:

1-503-684-3332

declare that the product

Product No.:

THC138

Product Name: Multi-channel Cable Free Remote Thermo Sensor
Manufacturer:

IDT Technology Limited

Address:

Block C, 9/F, Kaiser Estate,
Phase 1,41 Man Yue St.,
Hung Hom, Kowloon,
Hong Kong

is in conformity with Part 15 of the FCC Rules.  Operation is subject to
the following two conditions: 1) This device may not cause harmful
interference. 2) This device must accept any interference received,
including interference that may cause undesired operation.

Отзывы: