INTRODUCTION
Thank you for selecting this Oregon Scientific
TM
Wireless
Indoor / Outdoor Thermometer with Indoor Humidity and Self-
Setting Atomic clock (RMR683HGA)
. This clock is supplied
with a remote sensor (THN122N) and can support up to 3
sensors in total (additional sensors sold separately).
NOTE
Please keep this manual handy as you use your new
product. It contains practical step-by-step instructions, as well as
technical specifications and warnings you should know about.
CLOCK OVERVIEW
FRONT VIEW
1.
SNOOZE
2. Temperature
and
Humidity Area
3. Clock / Alarm Area
BACK VIEW
1.
TEMP / HUMIDITY HI / LO
:
Change settings or enable
/ disable
hi or lo
temperature / humidity alarm
2.
/
: Increase / decrease setting; activate / deactivate
clock reception signal
3.
CHANNEL:
Switch remote sensor display
4.
HEAT INDEX
5.
MODE:
Change settings / display
6.
ALARM:
View alarm status; set alarm
7. Battery compartment
8.
MEM:
View current, maximum and minimum
temperature / humidity
9.
°
C /
°
F:
Select temperature unit
10.
ZONE:
Toggle US time
zone
11.
RESET:
Reset unit to default settings
LCD DISPLAY
Temperature and Humidity area:
1
2
3
1
2
3
4
5
6
8
9
10
11
7
1
9
10
11
12
13
14
2
3
4
5
6
7
8
1. Heat index icon
2. Hi /
lo
temperature alarm
3. Max / Min temperature icon
4. Sensor reception icon
5. Comfort Zone
6. Battery low icon
7. Hi /
lo
humidity alarm
8. Max / Min humidity icon
9.
Ice warning is active
10. Temperature trend
11. Temperature
12. Heat Index Warning
13. Humidity
14. Humidity Trend
Clock / Alarm area:
1. Clock signal reception
2.
AM / PM
mode selected
3. Alarm mode
4. Alarm set
5.
AM / PM
mode selected
6. Alarm time
7. US time zone
8. Clock
9. Moon Phase
REMOTE SENSOR (THN122N)
1. LED status indicator:
1. Wall mount hole
Blinks red during data
2.
RESET
hole
transmission
3.
CHANNEL
switch
2. Ventilation duct
4. Battery compartment
GETTING STARTED
SETTING UP THE CLOCK
Insert batteries before first use, matching the polarity (+ and -).
RESET
after each battery change.
indicates main unit batteries are low.
NOTE
Do not use rechargeable batteries. We
recommend
that you use alkaline batteries with this product for longer
usage and lithium batteries in temperatures below freezing.
REMOTE SENSOR
The sensor collects temperature readings approx. every 40
seconds and sends them to the main unit. The main unit can
collect data from up to 3 sensors.
To set up the sensor:
1. Remove the screws from the battery door.
2. Insert the batteries, matching the polarity (+ / -).
3. Select a channel. Make sure you use a different channel
for each sensor.
4. Place the sensor near the main unit. Press
RESET
on
the sensor.
5. Simultaneously press
CHANNEL
and
MEM
on the main
unit to initiate signal sending between the sensor and
main unit.
1
7
8
9
2
3
4
5
6
1
2
1
2
3
4
6. Close the battery door and secure the screws.
7. Place the sensor in the desired location using the table
stand or wall mount.
For best results:
•
Place the sensor out of direct sunlight and moisture.
•
Do not place the sensor more than 30 m (
100 ft
) from the
main (indoor) unit.
•
Position the sensor so that it faces the main (indoor) unit,
minimizing obstructions such as doors, walls, and
furniture.
•
Place the sensor in a location with a clear view to the
sky, away from metallic or electronic objects.
•
Position the sensor close to the main unit during cold
winter months as below-freezing temperatures may affect
battery performance and signal transmission.
The transmission range may vary depending on many factors.
You may need to experiment with various locations to get
the best results.
Standard Alkaline batteries contain significant amounts of
water. Because of this they will freeze in low temperatures of
approximately -12
°
C (10
°
F). Disposable Lithium batteries
have a much lower threshold for temperature with an
estimated freezing range of below -30
°
C (-22
°
F).
Wireless ranges can be impacted by a variety of factors such
as extremely cold temperatures. Extreme cold may temporarily
reduce the effective range between the sensor and the base
station. If the unit’s performance fails due to low temperature,
the unit will resume proper functioning as the temperature
rises to within the normal temperature range (i.e. no permanent
damage will occur to the unit due to low temperatures).
SENSOR DATA TRANSMISSION
Data is sent from the sensor(s) every 40 seconds. The sensor
reception icon in the temperature and humidity area shows
the status.
ICON
DESCRIPTION
Main unit is searching for the
sensor(s)
A channel has been found
Sensor 1 is sending data
and “- - . -“
The sensor cannot be found.
(Temperature
Search for the sensor or
and Humidity
Area)
check batteries
To search for a sensor:
Simultaneously, press and hold
MEM
and
CHANNEL
for 2
seconds.
NOTE
If the sensor is still not found, check the batteries,
obstructions, and remote unit location.
CLOCK
CLOCK RECEPTION
This product is designed to synchronize its date and time
automatically once it is within range of the WWVB-60 signal
from the atomic clock in Boulder, Colorado.
The sensor collects the radio signals whenever it is within
1500 km (932 miles) of a signal.
NOTE
Initial reception takes 2-10 minutes for first set up or
when
RESET
is pressed. Once complete, the reception icon
will stop blinking. If the signal is weak, it can take up to 24
hours to get a valid signal.
RECEPTION SIGNAL
Clock signal reception indicator:
STRONG SIGNAL
WEAK SIGNAL
NO SIGNAL
To enable and force a signal search:
Press and hold
for 2 seconds.
To disable the signal reception:
Press and hold
for 2 seconds.
flashes when it is
disabled.
SET CLOCK
To manually set the clock make sure the clock signal reception
is disabled.
To manually set the clock:
1. Press and hold
MODE
for 2 seconds.
Wireless Indoor / Outdoor
Thermometer with Indoor Humidity and
Self-Setting Atomic Clock
Model: RMR683HGA
USER MANUAL