background image

EN

7

For best results:

• Insert the batteries and select the channel and

temperature unit before you mount the sensor.

• Place the sensor out of direct sunlight and

moisture.

• Do not place the sensor more than 30 meters

(98 feet) from the main (indoor) unit.

• Position the sensor so that it faces the main

(indoor) unit, minimizing obstructions such as
doors, walls, and furniture.

• Place the sensor in a location with a clear view

to the sky, away from metallic or electronic
objects.

• Position the sensor close to the main unit

during cold winter months as below-freezing
temperatures may affect battery performance
and signal transmission.

You may need to experiment with various locations to
get the best results.

SEARCH FOR SENSOR

To  search for a sensor, press and hold 

MEM

  and

CHANNEL

 for 2 seconds.

If the sensor is still not found, check the

batteries, obstructions, and remote unit location.

Signals from household devices such as

doorbells, electronic garage doors, and home security
systems may cause temporary reception failure. This is
normal and does not affect general product performance.
The reception will resume once the interference ends.

NOTE

DATA TRANSMISSION

Data is sent from the sensor(s) every 40 seconds.
The reception icon shown in the Temperature and
Humidity Areas shows the status.

--- shows in Temp/
Humidity Areas

ICON

DESCRIPTION

Main unit is searching for
sensors.

At least 1 channel has
been found.
Channel 1 is selected (the
number will change
depending on the sensor
you select).

The selected sensor cannot
be found. Search for the
sensor or check batteries.

NOTE

RMR612HGA lab test R2

1/17/04, 4:58 PM

7

Содержание RMR612HGA

Страница 1: ...Wireless Thermo Hygro Clock Model RMR612HGA User Manual RMR612HGA lab test cover R2 1 8 04 7 00 PM 1...

Страница 2: ...Switch Clock Display 8 Alarm 9 View Alarm Settings 9 Set Alarm 9 Activate Alarm 9 Silence Alarm 9 Temperature and Humidity 9 Select Temperature Unit 9 Select Sensor Channel 9 Minimum Maximum Records...

Страница 3: ...THGR122NX Keep this manual handy as you use your new product It contains practical step by step instructions as well as technical specifications and warnings you should know ABOUT OREGON SCIENTIFIC V...

Страница 4: ...Readings trend line remote unit reception and channel number 3 Clock Alarm Area Time time zone day of week alarm and Atomic Clock reception status 4 Temperature Area Readings trend line and battery s...

Страница 5: ...RESET hole located in battery compartment 6 MODE button Change display settings 7 Increase setting activate Atomic Clock signal reception 8 Decrease setting 9 C F switch located in battery compartment...

Страница 6: ...SENSOR THGR122NX 1 LCD display 2 LED Status indicator 1 Wall mount hole 2 RESET 3 Channel number 1 3 4 Battery compartment Battery compartment cover not shown 1 2 1 2 3 4 RMR612HGA lab test R2 1 17 0...

Страница 7: ...a can be collected from up to 3 sensors Additional sensors sold separately 3 Place the sensor near the main unit Press RESET on the sensor to initiate signal sending between the sensor and the main un...

Страница 8: ...RCH FOR SENSOR To search for a sensor press and hold MEM and CHANNEL for 2 seconds If the sensor is still not found check the batteries obstructions and remote unit location Signals from household dev...

Страница 9: ...and hold ZONE located in the battery compartment for 2 seconds Then manually set the clock following the Set Clock instructions below The signal icon indicates that the Atomic Clock feature is ON No...

Страница 10: ...automatically silence after 2 minutes It will then sound again after 8 minutes TEMPERATURE AND HUMIDITY This product can display the following temperature and humidity information Current minimum and...

Страница 11: ...lcohol free mild detergent Avoid dropping the product or placing it in a high traffic location To auto scan between sensors press and hold CHANNEL for 2 seconds Each sensor s data will be displayed fo...

Страница 12: ...of service if handled properly Observe the following guidelines Never immerse the product in water This can cause electrical shock and damage the product Do not subject the main unit to extreme force...

Страница 13: ...eries 2 x UM 3 AA 1 5V alkaline Sensor batteries 2 x UM 4 AAA 1 5V alkaline SPECIFICATIONS MAIN UNIT DIMENSIONS L x W x H 105 x 35 x 116 mm 4 13 x 1 38 x 4 57 inches Weight 198 grams 6 98 ounces witho...

Страница 14: ...rence in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interferenc...

Страница 15: ...hone No 1 800 853 8883 Fax No 1 503 684 8883 declare that the product Product No RMR612HGA Product Name Wireless Thermo Hygro Clock Manufacturer IDT Technology Limited Address Block C 9 F Kaiser Estat...

Страница 16: ...2004 Oregon Scientific All rights reserved P N 086 003298 017 RMR612HGA lab test Back cover 12 29 03 10 43 PM 1 Black...

Отзывы: