Oregon Scientific RMR382A Скачать руководство пользователя страница 1

Wireless Indoor / Outdoor Thermometer 

with Self-Setting Atomic Clock

Model: RMR382A

USER MANUAL

 

INTRODUCTION

Thank you for selecting the Oregon Scientific

TM

 Wireless 

Indoor / Outdoor Thermometer with Self-Setting Atomic 
Clock. The main unit can support up to 3 sensors. To 
purchase additional sensors, please contact your local 
retailer.
 

NOTE

    Please  keep  this  manual  handy  as  you  use 

your  new  product.  It  contains  practical  step-by-step 
instructions,  as  well  as  technical  specifications  and 
warnings you should know about.

OVERVIEW
FRONT VIEW

1.   Channel number and sensor reception status
2.   Sensor low battery warning
3.   Maximum / minimum outdoor temperature reading
4.   Indoor temperature display icon
5.   Main unit low battery warning
6.   Maximum / minimum indoor temperature reading
7.   Alarm is set 
8.   12-hour clock
9.   Alarm is displayed
10. Radio-controlled clock reception icon
11.  Hi / lo alarm is displayed
12. Outdoor temperature trend icon
13. Ice warning is active 
14. Outdoor temperature reading 
15. Indoor temperature trend icon
16. Indoor temperature reading 
17. US time zones
18. Time, alarm and date
19. 

ALARM   

: View alarm status; set alarm

BACK VIEW

 

1.      /   

:

 Increase / decrease setting; activate /  

deactivate clock reception signal 

2.  

MODE:

 Change settings / display

3. 

CHANNEL:

 Switch remote sensor display 

4.  

MEM:

 View current, maximum and minimum 

    temperature 

5.  

°C / °F:

 Select temperature unit °C / °F

6.  

TEMP HI / LO

   

:

 Change settings or enable / 

 

disable hi or lo temperature alarm for channel 1

7. 

RESET:

 Reset unit to default settings

8.  

ZONE:

 Toggle between the 4 US time zones

9. 

Battery compartment

REMOTE SENSOR (THN132N)

 

 

1. LED indicator 

1.  Wall mount

   

2.  Battery compartment

   

3.  Battery door

   

4.  Table stand

   

5. 

RESET

 hole   

   

6. 

CHANNEL

 switch

GETTING STARTED
POWER

Insert  batteries  before  first  use,  matching  the  polarity      
(+ and -).

NOTE

  Install batteries in the remote sensor before the 

main unit. Press 

RESET

 after each battery change. Do not 

use rechargeable batteries. We recommend that you use 
alkaline batteries with this product for longer usage and 
lithium batteries in temperatures below freezing.

          shows when batteries are low.

UNIT

 

          

LOCATION

Main 

 

Indoor temperature area

Remote   

Outdoor temperature area

REMOTE SENSOR

The sensor collects temperature readings approx. every 
40 seconds and sends them to the main unit. The main 
unit can collect data from up to 3 sensors.
To set up the sensor:
1.  Slide open the battery door.
2.  Insert  the  batteries,  matching  the  polarity    (+  /  -). 

Reset after each battery change.

3.  Select  a  channel.  Make  sure  you  use  a  different 

channel for each sensor.

4.  Close the battery compartment.
5.  Secure the sensor in the desired location using the 

wall mount or table stand. 

 

For best results:

•   Place the sensor out of direct sunlight and moisture. 
•   Do not place the sensor more than 30 meters (100 

feet) from the main (indoor) unit.

•   Position the sensor so that it faces the main (indoor) 

unit, minimizing obstructions such as doors, walls, and 
furniture.

•  Place the sensor in a location with a clear view to the 

sky, away from metallic or electronic objects.

•   Position the sensor close to the main unit during cold 

winter months as below-freezing temperatures may 
affect battery performance and signal transmission. 

The  transmission  range  may  vary  depending  on  many 
factors.  You  may  need  to  experiment  with  various 
locations to get the best results.

Standard Alkaline batteries contain significant amounts of 
water. Because of this they will freeze in low temperatures 
of  approximately  -12°C  (10°F).  Disposable  Lithium 
batteries have a much lower threshold for temperature 
with  an  estimated  freezing  range  of  below  -30°C
(-22°F).

Wireless ranges can be impacted by a variety of factors 
such as extremely cold temperatures. Extreme cold may 
temporarily reduce the effective range between the sensor 
and the base station. If the unit’s performance fails due to 
low temperature, the unit will resume proper functioning 
as the temperature rises to within the normal temperature 
range (i.e. no permanent damage will occur to the unit due 
to low temperatures). 

SENSOR DATA TRANSMISSION

The reception icon in the outdoor temperature area shows 
the status.

ICON 

 DESCRIPTION

  

Main unit is searching for the  

 

 

sensor(s)

  

A channel has been found and  

 

sensor signal is being received 

 

The sensor cannot be found.

 

Search for the sensor or check 

 

batteries

To search for a sensor:

 

Simultaneously,  press  and  hold 

MEM

  and 

CHANNEL

 

for 2 seconds.

NOTE

  If the sensor is still not found, check the batteries, 

obstructions, and remote unit location.

CLOCK 
CLOCK RECEPTION 

This product is designed to synchronize its date and time 
automatically  once  it  is  within  range  of  the  WWVB-60 
signal from the atomic clock in Fort Collins, Colorado.
The clock collects the radio signals whenever it is within 
3218 km (2000 miles) of a signal.

NOTE

   Initial reception takes 2-10 minutes for first set up 

or when 

RESET

 is pressed. Once complete, the reception 

icon will stop blinking. If the signal is weak, it can take up to 
24 hours to get a valid signal.

RECEPTION SIGNAL

 

  STRONG 

WEAK 

         NO SIGNAL

  

  

 

To enable and force a signal search:

Press and hold 

 for 2 seconds.

To disable the signal reception:

Press and hold 

 for 2 seconds.

SET CLOCK

 

If  the  clock  signal  reception  is  enabled  and  a  signal  is 
being received the clock does not need to be manually 
set. 

To manually set the clock:

1.   Press and hold 

MODE

 for 2 seconds.

2.   Press 

 and 

 to change the settings.

3.   Press 

MODE

 to confirm.

4.   The setting sequence is: 12 / 24 hour format, hour, 

minute, year, date / month format, month, date, and 
display language. 

         and “- -.-”(Outdoor 
temperature area)

1

1

11

13
14

15

16

17

18

19

12

2

3

4
5

6

7

8

9

10

1

2

3

1

2

3

4

6

5

1

2

3

4

5

6

7

8

9

RMR382A 086L004376-010_R1.indd   1

4/3/06   10:32:05 AM

Отзывы: