background image

EN

INtroductIoN

Thank  you  for  selecting  the  Oregon  Scientific™  PRYSMAchrome 

Weather Station. This device bundles precise time keeping, alarm, and 

temperature monitoring features into a single tool you can use from the 

convenience  of  your  home.  Keep  this  manual  handy  as  you  use  your 

new product. It contains practical step-by-step instructions, as well as 

technical specifications and warnings you should know.

Lcd dIspLay

Time Display

Outdoor/Indoor

temperature display

Weather 

forecast display

Outdoor/Indoor

humidity display

Icon

Description

In humidity display area 

(   ): Low battery in remote sensor

In time display area 

(   ): Low battery in main unit backup 

battery (CR2032).
Remote sensor channel number

Temperature/humidity auto-loop indicator
Indoor temperature/humidity indicator

Humidity display indicator (%)

Temperature display indicator (°C/°F)

Alarm is on.

RCC signal reception indicator

oVErVIEW

top VIEW

   - Press to toggle the alarm display and alarm on/off. Press and hold 

to enter alarm setting.   

   - Press to toggle between time and date display. Press and hold to 

enter the setting.

 

 - Tap to snooze an alarm or activate the brightest backlight 

for 5 seconds.

   - Press to increase the value in setting, or press and hold to increase 

a value rapidly in setting. Press to toggle the remote sensor channels 

in ascending order, or press and hold to search for the remote sensor.

    -  Press  to  decrease  the  value  in  setting,  or  press  and  hold  to 

decrease a value rapidly in setting. Press to toggle the remote sensor 

channels in descending order, or press and hold to remove selected 

remote sensor.

rEar VIEW 

 

 - Press to reset the unit to default.

 

 - Press to turn on the RCC signal reception. Press and hold to 

turn off.

 

 - Micro USB power jack 

 

 - Press to toggle the temperature unit.

 

 - Press to toggle the backlight brightness level. Press and hold 

to set the back light color.

remote sensor

 

cH

  Channel 1-5. If more than one sensor is being used, make sure 

each one has a different channel number.

 

rEsEt

  Press  if  the  sensor  is  not  working  correctly,  after  battery 

replacement or channel change.

GEttING startEd

connecting the main unit to power supply

Connect  the  power  cable  to  the  Micro  USB  jack  and  plug  the  power 

adaptor into a suitable power outlet.

Inserting batteries into remote thermo sensor

1. Slide down the battery compartment cover to open, then insert 2 “AAA” 

batteries, matching the polarity as shown.

2. Press 

 . Slide to replace the battery compartment cover.

NOTE

 The main unit can connect up to 5 sensor. Press and hold + on 

the main unit to search for the remote sensor every time after adding a 

new sensor.

placement of the main unit 

•  Place the device as far as possible from computers and microwaves to 

avoid any interference.

•  Only use this device indoors in a dry location.

•  Leave space around the device for ventilation purposes.

•  To ensure for good sound quality, do not cover the speaker.  

placement of the remote thermo sensor

Min 5 ft (1.5 m)

Max 98 ft (30 m)

Place your sensor outside the home at a height of not more than 5 ft  

(1.5 m), shielded from direct sunlight or wet conditions.

•  The 

 icon on the main unit flashes while searching the signal from 

the remote sensor.

NOTE

  The  radio  signal  reaches  up  to  98  ft  (30  m)  depending  on 

conditions of surrounding.

replacing cr2032 backup battery

This unit is equipped with a CR2032 battery as a backup power source. 

When the main unit shows   , replace the CR2032 backup battery.

 

to replace a cr2032 backup battery

1. Open up the bottom left corner of the rubber cover, then gently push 

the arched part of the backup battery door downwards as shown 

above.

2. Replace the CR2032 backup battery to the compartment, then push 

the battery compartment back into the main unit. Connect the main 

unit to the power supply and then press 

 .

NOTE

 When replacing the backup battery, flip the bottom left corner 

rubber cover only. Do not remove the entire rubber cover.

tEMpEraturE sENsItIVE Lcd dIspLay

The  LCD  display  changes  colors  according  to  the  temperature  of  the 

first sensor with the lowest channel number available (e.g channel 1). If 

sensor channel 1 is not available, the LCD display will change its color 

according to the temperature of the next sensor channel (e.g. channel 2) 

available in ascending order. 
You  may  also  set  the  LCD  display  color  manually  by  press  and  hold 

 , then press   or    to toggle between the desired color number, 

or choose 

auto

 to change colors according to the temperature. 

Outdoor Temperature (Channel 1)

Color

Color number

≤ 5.9 °C

Purple

1

6 °C - 10.9 °C

Blue

2

11 °C - 15.9 °C

Pale blue

3

16 °C - 20.9 °C

Green

4

21 °C - 25.9 °C

Yellow

5

26 °C - 30 °C

Orange

6

≥30.1°C

Red

7

 

•  Tab 

 to activate the brightest backlight (LV. 3) display for 

5 seconds.

•  Press 

 repeatedly to toggle the desired backlight display 

brightness level (LV. 1/LV. 2/LV. 3).

•  The unit might take some time to change its LED display color.

radIo rEcEptIoN

This feature is not available for BAA292H. 
You may press and hold 

 to turn off the RCC signal icon on the LCD 

display. 

Symbol

Description

RCC is off

RCC Time is received

No RCC signal received

sEttING tIME MaNuaLLy

1. Press and hold   . The screen displays 

 and the number flashes.

2. Press once or press and hold   or   to adjust the setting. For EU/UK, 

the time-zone offset sets the clock up to +/- 23 hours from the received 

clock signal time. For US, the time-zone setting is Central (

c

); Eastern 

(

E

); Atlantic (

a

); Newfoundland (

N

); Pacific (

p

); Mountain (

M

).

3. Press   to confirm.
4. Press once or press and hold   or   to adjust the setting for 12/24 

hour  format,  hour,  minute,  year,  calendar  format  (month-day/day-

month), month, date and daylight saving time (

dst

) auto/off. 

5. Press   again to confirm.

NOTE

 

•  The daylight saving time (

dst

) setting is available for the United 

States only. 

•  The RCC and daylight saving time (

dst

) are disabled when the 

time/year, month or date is changed in the setting. The DST is also 

disabled when the RCC is turned off. If you turn the RCC back on, the 

DST resumes from the last setting.

•  While in the setting mode, press and hold   to save the settings and 

return to idle.

aLarM fuNctIoN

setting/adjusting alarm time 

1. Press and hold   .

2. Use   and   to adjust the hour and press   to confirm.

3. Use   and   to adjust the minute and press   to confirm.

4. The alarm icon displays in idle. When the alarm sounds, it lasts for 

2 minutes.

NOTE

 While in the alarm setting mode, press   to save the settings and 

leave the alarm setting mode.

snooze function

•  To use the 

 function, press the 

 on top of the clock 

when the alarm sounds. The alarm will stop and start again after 8 minutes.

activating/deactivating the alarm 

•  Press    to turn on the alarm, press  twice to turn off the alarm.

•  When  the  alarm  sounds,  press    to  stop  the  alarm.  The  alarm  will 

reactivate on the next day.

WEatHEr forEcast

This product forecasts the next 12 hours of weather in nearby area.

Screen display

Description

 

Sunny

 

Partly cloudy

 

 

Cloudy

 

Rainy

Snowy

tEMpEraturE aNd HuMIdIty fuNctIoN

The current outdoor/indoor temperature and humidity indicators locate at top 

and bottom left of the screen. To receive outdoor temperature and humidity 

information, you can connect up to 5 remote sensors to the main unit:

•  Press   or   to toggle sensor display.
 

NOTE

  When  the  indoor  temperature  is  lower  than  -5  °C  (23.0  °F),  the 

screen displays 

LL.L

. When it is higher than 50 °C (122.0 °F), the screen 

displays 

HH.H

When the indoor relative humidity is lower than 25%, the screen displays 

LL

. When it is higher than 95%, the screen displays 

HH

.

to auto-loop between sensors

:

Press    or   repeatedly until   displays. The data on each sensor 

displays for 3 seconds. Press +/-again turn off the auto-loop, the   icon 

turns off.

NOTE

 The sensor displays in ascending order. The main unit skips the 

absent sensor and advances to the next present sensor.

to search for remote sensors:

Press and hold   .

to remove selected sensor:

Press and hold   .

trouBLEsHoot

Problem

Reason

Solution

The main unit 

does not display 

at all.

The main unit is not 

connected to the 

power outlet.

Make sure the main unit is 

connected with the power adapter.

The outdoor display 

area is blank.

The outdoor sensor is 

removed.

Reconnect the outdoor sensor.

The outdoor 

display area 

displays ---.

The main unit is unable 

to receive data from 

the remote sensor.

Check the connection between the 

main unit and the sensor.

The main unit 

does not receive 

RCC signal.

BAA292H does not 

support RCC signal 

reception.

Press 

 to turn off the display 

icon.

The main unit 

does not display 

properly.

The main unit is unable 

to receive data from 

the remote sensor.

Press

 

 to reset the main 

unit.

prEcautIoNs

•  Do not subject the unit to excessive force, shock, dust, temperature 

or humidity.

•  Do  not  immerse  the  unit  in  water.  If  you  spill  liquid  over  it,  dry  it 

immediately with a soft, lint-free cloth.

•  Do not clean the unit with abrasive or corrosive materials.
•  Do not tamper with the unit’s internal components. This invalidates the 

warranty.

•  Only use fresh batteries. Do not mix new and old batteries.
•  Images shown in this manual may differ from the actual display.
•  When  disposing  this  product,  ensure  it  is  collected  separately  for 

special treatment.

•  Placement  of  this  product  on  certain  types  of  wood  may  result  in 

damage to its finish for which Oregon Scientific will not be responsible. 

Consult the furniture manufacturer’s care instructions for information.

•  The  contents  of  this  manual  may  not  be  reproduced  without  the 

permission of the manufacturer.

BAA292H

•  Do not dispose old batteries as unsorted municipal waste. Collection of 

such waste separately for special treatment is necessary.

•  Please note that some units are equipped with a battery safety strip. 

Remove the strip from the battery compartment before first use.

NOTE

 The technical specifications for this product and the contents 

of the user manual are subject to change without notice. To download 

an electronic copy of this user manual, please visit    

http://global.oregonscientific.com/customerSupport.php.

spEcIfIcatIoNs

MaIN uNIt

L x W x H

22 x 200 x 80 mm

Weight

224 g without batteries

Temperature range

-5.0 °C to +50.0 °C (23.0 °F to 122.0 °F)

Temperature accuracy

0°C to 40°C: ±1°C (± 2.0°F)

T<0°C : ±2°C (± 4.0°F)

T>40°C  : ±2°C (± 4.0°F)

Temperature resolution

0.1°C (0.2°F)

Relative humidity 

measurement 

25% to 95% RH  

Humidity accuracy

40% to 80% RH: ±5%

25% to 40% RH: ±7%

80% to 95% RH: ±7%

Power

5V adapter

CR2032 backup battery

rEMotE uNIt (tHGN130H)

L x W x H

125 x 50 x 19.5 mm

Weight

59 g without batteries

Transmission range

30 m (98 ft) unobstructed

Temperature range

-20 °C to 60 °C  (-4 °F to 140 °F)

Temperature accuracy

0°C to 40°C: ±1°C (± 2.0°F)

T<0°C : ±2°C (± 4.0°F)

T>40°C : ±2°C (± 4.0°F)

Temperature resolution

0.1 °C (0.2 °F)

Relative humidity 

measurement 

25% to 95% RH  

Humidity accuracy

40% to 80% RH: ±5%

25% to 40% RH: ±7%

80% to 95% RH: ±7%

Signal frequency

315 MHz

No. of channel selectable 

5

aBout orEGoN scIENtIfIc

Visit our website www.oregonscientific.com  to  learn  more  about 

Oregon Scientific products. 

For any inquiry, please contact our Customer Services at  

http://global.oregonscientific.com/customerSupport.php. 

Oregon  Scientific  Global  Distribution  Limited  reserves  the  right  to 

interpret and construe any contents, terms and provisions in this user 

manual  and  to  amend  it,  at  its  sole  discretion,  at  any  time  without 

prior notice. To the extent that there is any inconsistency between the 

English version and any other language versions, the English version 

shall prevail. 

fcc statEMENt

This device complies with Part 15 of the FCC Rules. Operation is subject 

to the following two conditions: (1) This device may not cause harmful 

interference, and (2) This device must accept any interference received, 

including interference that may cause undesired operation.

WARNING

  Changes  or  modifications  not  expressly  approved  by  the 

party  responsible  for  compliance  could  void  the  user’s  authority  to 

operate the equipment.

NOTE

  This  equipment  has  been  tested  and  found  to  comply  with  the 

limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. 

These  limits  are  designed  to  provide  reasonable  protection  against 

harmful interference in a residential installation.

This equipment generates, uses and can radiate radio frequency energy 

and, if not installed and used in accordance with the instructions, may 

cause harmful interference to radio communications. However, there is 

no guarantee that interference will not occur in a particular installation. 

If this equipment does cause harmful interference to radio or television 

reception, which can be determined by turning the equipment off and on, 

the user is encouraged to try to correct the nterference by one or more of 

the following measures:

Reorient or relocate the receiving antenna.

Increase  the  separation  between  the  equipment and receiver.

Connect the equipment into an outlet on a circuit different from that to which 

the receiver is connected.

Consult the dealer or an experienced radio / TV  technician for help.

dEcLaratIoN of coNforMIty

The  following  information  is  not  to  be  used  as  contact  for  support  or 

sales. Please call our customer service number (listed on our website at        

www.oregonscientific.com), or  on  the  warranty  card  for  this  product 

for  all  inquiries instead.
We

Name:                  

Oregon Scientific, Inc.

Address:                 

10778 SW Manhasset Dr.

                                   

UNIT  B-2  Tualatin, 

                                 

OR 97062 USA

Telephone No.:        

1-800-853-8883

declare that the product 

Product No.:              

BAA292H

Product Name:          

PRYSMAchrome 

Manufacturer: 

IDT Technology Limited

Address:    

Block C, 9/F, Kaiser Estate,

                          

Phase 1, 41 Man Yue St.,    

                            

Hung Hom, Kowloon, Hong Kong

is  in  conformity  with  Part  15  of  the  FCC  Rules.    Operation  is  subject 

to  the  following  two  conditions:  1)  This  device  may  not  cause  harmful 

interference.  2)  This  device  must  accept  any  interference  received, 

including interference that may cause undesired operation.

Eu-dEcLaratIoN of coNforMIty

Hereby,  Oregon  Scientific,  declares  that  this  PRYSMAchrome  Weather 

Station (Model: BAA292H) is in compliance with R&TTE directive 1999/5/

EC. A copy of the signed and dated Declaration of Conformity is available 

on request via our Oregon Scientific Customer Service.

dIsposaL INforMatIoN for usErs

Pursuant to and in accordance with Article 14 of the Directive 

2012/19/EU of the European Parliament on waste electrical and 

electronic equipment (WEEE), and pursuant to and in accordance 

with Article 20 of the Directive 2006/66/EC of the European 

Parliament on batteries and accumulators and waste batteries.

The barred symbol of the rubbish bin shown on the equipment indicates 

that, at the end of its useful life, the product must be collected separately 

from other waste.
Please note that the batteries/rechargeable batteries must be removed 

from the equipment before it is given as waste. To remove the batteries/

accumulators refer to the specifications in the user manual. Therefore, 

any products that have reached the end of their useful life must be given 

to waste disposal centers specializing in separate collection of waste 

electrical and electronic equipment, or given back to the dealer when 

purchasing a new WEEE, pursuant to and in accordance with Article 14 as 

implemented in the country.
The adequate separate collection for the subsequent start-up of the 

equipment sent to be recycled, treated and disposal of in an environmentally 

compatible way contributes to preventing possible negative effects on 

the environment and health and optimizes the recycling and reuse of 

components making up the apparatus.
Abusive disposal of the product by the user involves application of the 

administrative sanctions according to the laws in force.

tc

簡介

多謝閣下選購 

Oregon  Scientific™  PRYSMAchrome

  天氣站。此設備將準

確時間計算、響鬧和溫度監察功能集於一身。請將此手冊放置於容易取得

的地方,以隨時查看您應該了解的逐步操作說明、技術規格和警告事項。

LCD 螢幕

쩪甬秄䗨

ᚊᆦ즃ᚊ׾

㓨᯳秄䗨

ᆿㄶ礤ွ

秄䗨

ᚊᆦ즃ᚊ׾㛗

᯳秄䗨

圖示

描述

出現於濕度顯示區域

 (   ):遙控感應器的電量不足。

出現於時間顯示區域

 (   ):主裝置的後備電池電量不足 

(

CR2032

)。

遙控感應器頻道號碼

溫度/濕度自動循環指示器

室內溫度/濕度指示器

濕度指示器 (

%

)

溫度指示器 (

°C/°F

)

已開啟響鬧

RCC

 訊號接收指示器

概覽

俯視圖

   - 按下以切換響鬧顯示和開啟/關閉響鬧。長按以進入響鬧設定。
   - 按下以切換時間和日期。長按則可進入時間設定。
 

 - 輕按以暫停響鬧或以最光亮程度開啟背光燈5秒。

   - 按下以增加設定數值,或長按以快速增加設定數值。按下能以遞增

方式切換遙控感應器的頻道,或長按以搜尋遙控感應器。

    -  按下以減低設定數值,或長按以快速減低設定數值。按下能以遞減

方式切換遙控感應器的頻道,或長按以移除已選取的遙控感應器。

後視圖

 

 - 按下以重設裝置回預設置。

 

 - 按下以開啟

RCC

 訊號接收功能,長按則可關閉。

 

 - 

Micro

 電源插孔。

 

 - 按下以切換溫度單位。

 

 - 按下以切換背光燈的光度。長按則可設定背光燈的顏色。

遙控感應器

 

CH 

頻道  1-5。如果有多過一個感應器正在使用中,請確保每一個感應

器都有一個不同的頻道號碼。

  如果感應器不能正常操作或剛更換了電池,請按下此按鈕。

開始使用

將主裝置連接至電源

將電源線路連接至

Micro  USB

  插孔中,並將電源轉接器插入適當的電源插

座中。

將電池安裝至遙控熱能感應器中

1. 將電池槽蓋向下滑動以開啟槽蓋,並以符合電極的方式安裝 2 粒

「AAA」電池,如圖所示。

2. 按下 

 。將電池槽蓋向上滑動以裝回原位。

  主裝置可配備最多5個感應器。每次加入新遙控感應器後,請於主裝置

長按   以搜尋。

放置主裝置

•  請將設備盡量放置在遠離電腦和微波爐的地方,以免出現任何干擾。

•  請只在乾爽的室內環境中使用此設備。

•  在設備周圍預留一些空間以作通風之用。

•  為確保聲音品質良好,請勿覆蓋揚聲器。 

放置遙控熱能感應器

Min 5 ft (1.5 m)

Max 98 ft (30 m)

將感應器放置在家居的室外地方,其高度不應超過

5

呎 (

1.5

米), 並避免放

置於陽光直接照射或潮濕的環境中。
•  當從遙控感應器搜尋訊號時,主裝置上的 

 圖示便會閃動。

 無線電訊號最多可傳達至

98

呎(

30

 米)的距離,視乎四周的環境而定。

更換

CR2032

 後備電池

此裝置配備了一粒 

CR2032

 電池以作後備電源。當主裝置顯示   時,請更

換 

CR2032

 後備電池。   

 

如要更換 

CR2032

 後備電池

1. 打開橡膠蓋面的左下角,然後將後備電池槽蓋拱起的部份輕輕地向下

推,如上圖所示。

2. 更換電池插槽中的 

CR2032

 後備電池,然後將電池插槽推回主裝置中,

插上電源後按 

 當更換後備電池時,請只掀開橡膠蓋面的左下角。請勿將整塊橡膠蓋

面移除。

溫度感應 

LCD

 螢幕

LCD

  螢幕的顏色,會根據最低頻道號碼且可使用的感應器溫度而轉變  (例

如頻道 

1

)。如果感應器頻道 

1

  為不能使用,

LCD

  螢幕的顏色則會根據下

一個感應器頻道  (以遞增方式尋找下一個可使用頻道)  的溫度而轉變  (例如

頻道 

2

)。您亦可以手動設定

LCD

  螢幕的顏色,只需長按 

,然後按 

  或    來切換不同的顏色  (請參閱下表),或選擇

Auto

  以根據溫度來改

變顏色。

室外溫度

顏色

顏色號碼

≤ 5.9 ℃

紫色

1

6 ℃ - 10.9 ℃

藍色

2

11 ℃ - 15.9 ℃

淺藍色

3

16 ℃ - 20.9 ℃

綠色

4

21 ℃ - 25.9 ℃

黃色

5

26 ℃ - 30 ℃

橙色

6

≥30.1℃

紅色

7

 

•  輕按 

 來以最光亮程度 (

LV. 3

)啟動背光燈

5

秒。

•  重覆地按下 

 以切換到喜歡的背光燈照明亮度 (

LV. 1/LV. 2/LV. 3

)。

•  此裝置可能需要一段時間來改變

LCD

螢幕的顏色。

無線電接收

此功能不適用於

BAA292H

你可以長按 

 以關閉

LCD

螢幕上的顯示。

符號

描述

已關閉

RCC

已接收

RCC

  時間

沒有接收到 

RCC

訊號

手動設定時鐘

1. 長按   . 畫面會顯示 

 以及數字閃動。

2. 按一次或長按 

  或    以調整設定數值。對於歐洲/英國,時區偏移

會從所接收到的時鐘訊號時間將時鐘最多設定為  +/- 

23

小時。而美國地

區,時區設定為中部  (

C

)、東岸  (

E

)、大西洋  (

A

)、紐芬蘭  (

N

)、太平洋 

(

P

) 及山區 (

M

)。

3. 按下   以確定。
4. 按下或長按   或   來調教以下設定:

12/24

 小時格式、小時、分鐘、

年份、行事曆格式  (月份-日子/日子-月份)、月份、日期及日光節約時間 

(

DST

) 為自動/關閉。 

5. 再次按下   以確定。

 

•  日光節約時間 (

DST

) 設定只在美國提供。

•  當在設定中變更了時間/年份、月份或日期後,

RCC

 及日光節約時

間 (

DST

) 便會關閉。當 

RCC

  關閉時 

DST

 亦會關閉。如果再次開啟

RCC

DST

則會重設回最後的設定數值。

•  在設定模式中,按下   來儲存設定及回到閒置狀態。

響鬧功能

設定/調教響鬧時間

1. 長按   。
2. 使用   或   來調教小時,並按下   來確定。
3. 使用   或   來調教分鐘,並按下   來確定和回到閒置狀態。
4. 閒置時會顯示響鬧圖示。當響鬧響起,聲音會持續

2

分鐘。

 當在響鬧設定模式時,按下    便可儲存設定和回到閒置狀態。

小睡功能

•  如要使用小睡功能,當響鬧響起時請按下時鐘頂部的 

,響鬧便

會停止,並在

8

分鐘後再次響起。

啟動/關閉響鬧

•  按下    來開啟響鬧,按    兩次則可將響鬧關閉。
•  當響鬧響起時,按下    便可停止。響鬧將會在下一天再次啟動。

天氣預測

此產品能預測未來 

12

小時附近地區的天氣狀況。

顯示畫面

描述

 

晴天

 

間中有陽光

 

 

陰天

 

下雨

下雪

Отзывы: