background image

1

EN

Alarm ...................................................................... 11

View Alarm Settings ......................................... 11
Set Alarm .......................................................... 11
Activate Alarm .................................................. 11
Silence Alarm ................................................... 12

Weather Forecast .................................................. 12
Temperature .......................................................... 13

Select Temperature Unit ................................... 13
Minimum / Maximum Records .......................... 13

Moon Phase ........................................................... 13
Backlight ................................................................ 13
Reset System ........................................................ 14
Projection Unit ...................................................... 14
Safety and Care ..................................................... 14
Warnings ................................................................ 14
Troubleshooting .................................................... 15
Specifications ........................................................ 16

Main Unit Dimensions ...................................... 16
Remote Sensor Dimensions ............................. 16
Temperature ..................................................... 16
Remote Sensor (THN122N) ............................. 16
Clock / Projector ............................................... 16
Power ............................................................... 17

About Oregon Scientific ....................................... 17
FCC Statement ...................................................... 18

Declaration of Conformity ................................. 19

CONTENTS

Contents ................................................................ 1
Introduction ........................................................... 2
Product Overview ................................................. 2

Front View ......................................................... 2
Back View ......................................................... 3
LCD Display ...................................................... 4
Remote Sensor (THN122N) .............................. 5

Getting Started ...................................................... 6

Batteries ............................................................ 6
AC Adaptor ........................................................ 7
Adjust Settings .................................................. 7

Remote Sensor (THN122N) .................................. 8

Set Up Sensor ................................................... 8
Data Transmission ............................................ 9
Search for Sensor ............................................. 10

Clock ...................................................................... 10

Turn Atomic Clock Signal ON / OFF ................. 10
Set Time Zone / Clock / Calendar ..................... 11
Switch Clock Display ......................................... 11

Atomic Projection Clock with

Weather Forecast

Model: BAR623PA

USER MANUAL

All manuals and user guides at all-guides.com

all-guides.com

Содержание BAR623PA

Страница 1: ...k Projector 16 Power 17 About Oregon Scientific 17 FCC Statement 18 Declaration of Conformity 19 CONTENTS Contents 1 Introduction 2 Product Overview 2 Front View 2 Back View 3 LCD Display 4 Remote Sensor THN122N 5 Getting Started 6 Batteries 6 AC Adaptor 7 Adjust Settings 7 Remote Sensor THN122N 8 Set Up Sensor 8 Data Transmission 9 Search for Sensor 10 Clock 10 Turn Atomic Clock Signal ON OFF 10 ...

Страница 2: ...jection clock Main unit 4 5V AC DC adaptor Remote sensor THN122N Keep this manual handy as you use your new product It contains practical step by step instructions as well as technical specifications and warnings you should know PRODUCT OVERVIEW FRONT VIEW 1 SNOOZE LIGHT button 2 and Increase or decrease setting activate or deactivate atomic clock 3 MODE Change display settings 4 View alarm status...

Страница 3: ...adaptor plug cover 5 Battery compartment cover off 6 SEARCH button to locate the remote sensor 7 MEM View current maximum and minimum temperature readings 8 C F switch 9 RESET hole 10 Battery compartment cover on 11 Fixed table stand 1 2 3 6 7 8 9 5 4 10 11 All manuals and user guides at all guides com ...

Страница 4: ... 3 Alarm activated 4 Alarm setting 5 Time 6 Indoor temperature 7 Low battery icon for main unit 8 C F Outdoor temperature 9 Sensor signal 10 Low battery icon for sensor 11 Outdoor temperature 12 Calendar 13 Moon Phase All manuals and user guides at all guides com ...

Страница 5: ...5 REMOTE SENSOR THN122N 1 Wall mount hole 2 RESET hole 3 CHANNEL number 1 3 4 Battery compartment Battery compartment cover not shown 1 LED status indicator All manuals and user guides at all guides com ...

Страница 6: ...before first use matching the polarity and as shown in the battery compartment For best results install batteries in the remote sensor before the main unit Press RESET after each battery change NOTE Do not use rechargeable batteries shows when batteries are low NOTE It is recommended that you use alkaline batteries with this product for longer performance All manuals and user guides at all guides ...

Страница 7: ...rojection Inserting the adaptor ADJUST SETTINGS To adjust the time calendar and language settings 1 Press and hold MODE for 2 seconds to enter setting mode 2 Press or to change settings To reach the setting you want quickly press and hold or 3 Press MODE to confirm All manuals and user guides at all guides com ...

Страница 8: ... 3 Set the channel switch to any channel The switch is located in the battery compartment 4 Place the sensor near the main unit Press RESET on the sensor Then press and hold SEARCH on the main unit to initiate signal sending between the sensor and the main unit The reception icon on the main unit will blink for approximately 3 minutes while it is searching for the sensor Refer to the Data Transmis...

Страница 9: ...Disposable Lithium batteries have a much lower threshold for temperature with an estimated freezing range of below 40 F The Liquid Crystal Display in outdoor thermometers will remain operational to 20 F with adequate power Wireless ranges can be impacted by a variety of factors such as extremely cold temperatures Extreme cold may temporarily reduce the effective range between the sensor and the ba...

Страница 10: ...not found check the batteries obstructions and remote unit location NOTE Signals from household devices such as doorbells electronic garage doors and home security systems may cause temporary reception failure This is normal and does not affect general product performance The reception will resume once the interference ends CLOCK The clock automatically synchronizes the current time and date when ...

Страница 11: ...and EA Eastern NOTE The language options are E English F French D German I Italian and S Spanish SWITCH CLOCK DISPLAY Press MODE to toggle between Clock with Seconds and Clock with Weekday display ALARM This product is equipped with a 2 minute crescendo alarm VIEW ALARM SETTINGS Press The alarm time and status will show in the Clock Area SET ALARM 1 Press to switch to alarm display 2 Press and hol...

Страница 12: ...ivate it again after 24 hours If no button is pressed the alarm will automatically silence after 2 minutes It will then sound again after 8 minutes WEATHER FORECAST This product forecasts the weather for the next 12 to 24 hours within a 19 31 mile 30 50 km radius with 70 to 75 percent accuracy The weather forecast is displayed as below SUNNY PARTLY CLOUDY RAINY CLOUDY All manuals and user guides a...

Страница 13: ...ATURE UNIT Slide the C F switch into the desired location The switch is located in the main unit battery compartment The setting for the main unit overrides the remote sensor setting MINIMUM MAXIMUM RECORDS The MEM button is located in the main unit battery compartment Press MEM to toggle between current maximum MAX and minimum MIN records To clear the records press and hold MEM for 2 seconds A be...

Страница 14: ...ess the supplied AC DC adaptor is used You can also Adjust the FOCUS knob to make the image clearer Adjust the IMAGE ROTATION knob to rotate the image clockwise or anti clockwise Manually tilt the projection unit to position the image vertically upwards or downwards SAFETY AND CARE Clean the product with a slightly damp cloth and alcohol free mild detergent Avoid dropping the product or placing it...

Страница 15: ...cratch the LCD display NOTE The technical specification of this product and contents of this user guide are subject to change without notice Images not drawn to scale TROUBLESHOOTING REMEDY Change language Disable clock 1 Adjust batteries 2 Press RESET 3 Manually activate clock feature Temperature is out of range Check batteries Check location Initiate a manual sensor search PROBLEM Calendar Clock...

Страница 16: ...Unit C F Indoor range 23 F to 122 F 5 C to 50 C Outdoor range 22 F to 140 F 30 C to 60 C Resolution 0 2 F 0 1 C Display Rainy cloudy partly cloudy sunny REMOTE SENSOR THN122N RF frequency 433 MHz Range 98 feet 30 meters with no obstructions Transmission Every 40 seconds Channel No 1 CLOCK PROJECTOR Atomic Clock Auto or manual disabled Clock display HH MM SS Hour format 12hr AM PM Model BAR623PA Al...

Страница 17: ...children s electronic learning products and games projection clocks health and fitness gear weather stations and digital and conference phones The website also includes contact information for our customer care department in case you need to reach us as well as frequently asked questions and customer downloads We hope you will find all the information you need on our website however if you re in t...

Страница 18: ...hanges or modifications to this unit not expressly approved by the party responsible for compliance could void the user s authority to operate the equipment NOTE This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential ...

Страница 19: ...phone No 1 800 853 8883 Fax No 1 503 684 8883 declare that the product Product No BAR623PA Product Name Weather Projection Clock Manufacturer IDT Technology Limited Address Block C 9 F Kaiser Estate Phase 1 41 Man Yue St Hung Hom Kowloon Hong Kong is in conformity with Part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference 2 T...

Страница 20: ...Atomic Projection Clock with Weather Forecast Model BAR623PA USER MANUAL All manuals and user guides at all guides com ...

Страница 21: ... 2004 Oregon Scientific All rights reserved P N 086 003565 015 All manuals and user guides at all guides com a l l g u i d e s c o m ...

Отзывы: