Orcomm ORC-LEAK-WD-WH Скачать руководство пользователя страница 2

 

 

 

 

Wired water leak sensor (ORC-LEAK-WD-WH) 

Low Profile Water sensors that can be installed in areas vulnerable to water leak.  

Specification 

 

L64 x W16 x H13mm (excluding wire)  

 

Housing Material 

 ABS White 

 

Working Voltage 5 

 12V DC (Red is Positive and White is Ground)  

 

Max voltage 

 (Peak) 24V DC  

 

Max current 0.5A  

 

Temperature -10 to +65 C  

 

Wire cored 

 up to 350mm length  

 

Wire termination Red= (+), White= (-)  

 

Output type NPN type  

 

Installation 

This unit is designed for one use application. Once the unit has been submerged in water it must be 
replaced.  

Please follow the instructions of the monitoring device for any additional installation requirements.  

The Water Leak detection requires voltage to work correctly. It is NOT a passive device. Inside the unit 
contains electronic components that monitor the water across the 2x metal plates.  

 

 

 

Содержание ORC-LEAK-WD-WH

Страница 1: ...ouch Screen V2 8 2018 onwards 3 Wiring to Orcomm ORC HAGW V1 4 Testing the sensor 4 More information Links 4 ORC LEAK WD WH 4 Smart Home 4 Introduction This guide is designed to help understand orcomm offering for Water Leak detection via the Smart Home system For further installation instructions please refer to the Orcomm Smart Home Touch Screen Installation manual available at www orcomm co uk ...

Страница 2: ...perature 10 to 65 C Wire cored up to 350mm length Wire termination Red White Output type NPN type Installation This unit is designed for one use application Once the unit has been submerged in water it must be replaced Please follow the instructions of the monitoring device for any additional installation requirements The Water Leak detection requires voltage to work correctly It is NOT a passive ...

Страница 3: ...measure 4 to 5V DC in standby mode When Zones 1 8 are pulled below 1V DC the alarm will trigger Wiring to Orcomm Smart Touch Screen V2 8 2018 onwards The below can be followed when installing with monitors Version 2 Touch Screen Monitor will need to be set in 3C mode Voltage will measure between 2 to 3V DC in standby mode When Zones 1 8 are pulled higher than 4V DC the alarm will trigger ...

Страница 4: ... Analogue Input is pulled down more than 1V DC the alarm will trigger Testing the sensor When testing the sensor short the 2 blades on the water leak sensor together with a metal wire The monitoring device will then detect the connection and trigger as per designed application More information Links ORC LEAK WD WH https www orcomm co uk product orc leak wd wh Smart Home https www orcomm co uk prod...