WARNING!
In case of malfunction contact authorized customer service. Faulty parts can be only replaced with
original parts.
NEVER FIX THE DEVICE YOURSELF
! In case of unauthorized access to the unit or
replacement of faulty parts with non-original parts, the manufacturer will not be liable.
WARNING!
USER IS OBLIGED TO FOLLOW ABOVE INSTRUCTIONS FOR MAINTENANCE. IN CASE OF DEVICE
MALFUNCTION OR INJURIES DUE TO IMPROPER OR INSUFFICIENT MAINTENANCE BY THE USER,
THE MANUFACTURER WILL NOT BE LIABLE FOR THE CAUSED DAMAGE OR CONSEQUENCES.
20.2
Regular annual maintenance
To ensure optimal operation and long service life of the device, regular yearly maintenance must be
performed. When purchasing the unit, user agrees to allow regular maintenance from the authorized
customer service. Some of the main items which include regular annual service are:
-
Mg anode inspection
-
Pipe and wire device connections
-
Expansion vessel pressure inpection
-
Condensate draining pipes cleaning
-
Cold water inlet filter cleaning
-
Refrigerant pressure in the system
-
Functional test and device inspection
-
Electrical heater inspection
-
Operation control of electronic elements (compressor, ventilator, circulating pump, overflow valve,
diverter valve…)
-
Additional training of the user to ensure smooth operation of the device.
20.3
Malfunctions and resolutions
Malfunctions
Causes
Resolutions
Units doesn`t work
1.
Power supply failure
2.
Power supply connection failure
3.
Power supply fuse failure
1.
Cut down the power supply switch
and check power supply.
2.
Check out the reason and recover it.
3.
Renew the fuse after check.
High pressure
side of the
compressor
higher than normal
1.
Too much refrigerant
2.
Poor heat on evaporator
1.
Contact your local service.
Discharge over-charged refrigerant.
2.
Clean the evaporator.
Low pressure side
of the
compressor lower
than the normal
value
1.
Not enough refrigerant.
2.
The filter or the capillary is blocked
1.
Contact your local service. Check if
the system is leaking and fill the system
with refrigerant.
2.
Contact your local service. Change the
capillary or filter
No hot water
comes out of
the outlet.
1.
Tap water has been closed
2.
Water pressure is too low
3.
Inlet valve has been closed
1.
It’ll return to normal after tap water
is supplied.
2.
Run the unit when the water pressure
is higher.
3.
Open the inlet water valve.
Содержание ZEUS ZSW 230
Страница 23: ...User manual ZEUS 21 Example Running period 1 8 00 10 00 Running period 2 16 30 22 00 ...
Страница 24: ...User manual ZEUS 22 If you want to cancel the timer setting follow the instruction listed below ...
Страница 30: ...User manual ZEUS 28 18 1 Temperature sensor resistance ...
Страница 31: ...User manual ZEUS 29 19 UNIT COMPONENTS 18 UNIT COMPONENTS ...