Changing parameter values
1
2
NO.
DESIGNATION
FUNCTION
1
Input field - highlighted in yel-
low
Input fields highlighted in yellow mark all values currently
changed in the welding procedure that deviate from the cur-
rent memory value.
By saving the welding procedure again, the changed values
are applied and highlighted in gray.
NOTICE! The function serves as an orientation aid for the
user when creating and adjusting the welding procedure.
2
"Global Change" softkey
Pressing the "Global Change" softkey transfers the parame-
ter value currently marked with the menu cursor to all subse-
quent levels and existing values are overwritten.
NOTICE! The function serves the user as a convenience
function to adjust identical values across segments faster.
8.1.4.2.1 Documentation
All documentation fields defined in the program settings "Documentation" are displayed in the weld-
ing procedure segment Documentation.