background image

YARD ENFORCER

®

OFF

Turns the sensor and valve off. Must be in this mode to install batteries or to 

turn Intelligent Sensing on or off. Resets the time delays between valve 

activation if Intelligent Sensing is on.

DAY

Activates sensor and valve only during daylight.

Note: Sensor does not register actual time, but uses a photocell. Shady areas 

may cause the sensor to register day as night time.

NIGHT

Activates sensor and valve only when dark.

ALWAYS

Sensor and valve are always active.

DURATION ADJUSTMENT KNOB

Adjust the duration of the water from approximately 3 seconds to 10 seconds.

• Turn knob towards the + to increase how long the water sprays.

• Turn knob towards the – to decrease how long the water sprays.

SENSOR ADJUSTMENT KNOB

The sensor range is adjustable up to 40 ft. For smaller animals increase the 

distance the sensor monitors. For larger ones decrease the distance.

• Turn knob towards the + to increase the distance the sensor monitors.

• Turn knob towards the – to decrease the distance the sensor monitors.

30 MIN. WATER CYCLE BUTTON

• Press button to activate a 30 minute watering cycle.

• Press button again to stop the 30 minute watering cycle.

• A slight delay allows the user to move a safe distance away from the unit 

before watering begins

IN THE BOX

B

B

B

C

C

C

D

D

D

A

IMPACT SPRINKLER

HEAT SENSOR

RISER MOUNTING ARM

VALVE MOUNTING ARM

RISER AND VALVE

STEP SPIKE

A

A

B1

B1

B2

B2

B

WITH 

B2

 

ATTACHMENT

WITH 

B1

 

ATTACHMENT

WATERPROOF

BATTERY TRAY

BATTERIES 

NOT INCLUDED

1. Ensure the Riser Mounting Arm [B1] is atttached to the 
sensor.
2. Slip the mounting arm [B1] over the collar of the riser [C].
3. Thread the impact sprinkler [A] into the riser [C].
4. Thread the step-spike [D] onto the valve and tighten the 
swivel coupling.
5. Insert the valve cable into the sensor aligning the grooves.
6. Position the Heat Sensor at a 10° angle away 
from the ground.

1. Unscrew the Riser Mounting Arm [B1] and screw in the 
Valve Mounting Arm [B2] to the sensor.
2. Thread the impact sprinkler [A] into the riser [C].
3. Thread the step-spike [D] onto the valve and tighten the 
swivel coupling.
4. Mount the sensor unit [B] onto the front of the valve by 
sliding it onto the square bracket until it clicks into place.
5. Insert the valve cable into the sensor aligning the grooves.
6. Position the Heat Sensor at a 10° angle away 
from the ground. 

The sensor detects a combination of heat and nonlinear motion to activate 

the valve.

The sensor relies on the body temperature of the unwanted pest to differ from 

the surrounding ambient temperature.

Bigger animals have a larger heat signature and will be easier to detect. 

Smaller animals, like rodents, do not produce enough heat to trigger the heat 

sensor. 

ASSEMBLY FOR DETECTING LARGE ANIMALS

ASSEMBLY FOR DETECTING SMALL ANIMALS

HOW MOTION DETECTION WORKS

This mode conserves water and batteries by detecting significant, repeat activity 

(false alerts) and then reducing the frequency of activation. To disable Intelligent 

Sensing Mode: turn dial to OFF position then press and hold 30 MIN Watering 

button for 20 seconds until unit clicks. To re-enable Intelligent Sensing Mode: 

repeat steps above.

INTELLIGENT SENSING MODE

OPERATION FEATURES

AA AA AA AA

DURATION

30 MINUTE

WATER CYCLE

RANGE

DAY     N

IG

HT

   AL

WAY

S  

  O

FF

Dial

30 Minute Water

Cycle Button

Duration 

Adjustment 

Knob

Sensor Range

Adjustment 

Knob

10˚

10˚

WARNINGS

WHEN EXPECTING FREEZING TEMPERATURES,

REMOVE FROM THE HOSE AND STORE INDOORS.

FILTER WASHER TRAPS DIRT PARTICLES.

CLEAN FILTER REGULARLY AND REPLACE IF WORN.

INSTALLING THE BATTERIES

1. Verify the operation dial is in the

 

“OFF”

 

position.

2.

 

 Remove the tray on the back of the sensor by sliding it out.

Battery tray is waterproof. You may need to use a flathead 

screwdriver to push on the tab and slide the compartment out.

3.

 

 Insert four AA (1.5V) alkaline batteries (not included) as 

directed on the tray and replace the tray.

Note: Do not mix old and new batteries.

Use only alkaline batteries.

Отзывы: