TEC32-1664-009
OceanTRx7™ ADMx Technical Note
Page 10 of 10
4
Post replacement check
After the
ADMX
has been replaced, perform the following test procedures to verify system
functioning.
1. Start up the system (see the
OceanTRx7™ Installation and Operation Manual
for
instructions).
2. Verify that there are no ERR/WRN system messages and that there is communication
between the
CCU
and the
ACU
.
3. Perform 1dbcp with the NOC and confirm the system is back online.