Troubleshooting Using Status Indicators
Call
Out
Status LED or
Button
Icon and
Color
Description
1
Locate button/LED
Fault-Service
Required
Amber
Indicates the location of the power supply in the server:
■ Off – Power supply is operating normally,
■ Fast blink – Use Oracle ILOM to activate this LED to enable you to locate a power
supply quickly and easily.
■ Steady On –Lights steady on when the power supply is in a fault state.
2
OK
Power Supply OK
LED
Green
Indicates the functional state of the power supply:
■ Off – PS is disconnected
■ Steady On – PS is powered on and functionaing normally. When this LED is lit, the AC
OK LED is also lit.
Note -
Oracle ILOM signals a fault on any installed power supply that is not connected to an
AC power source, since it might indicate a loss of redundancy.
3
AC OK LED
Input ~AC
Green
Indicates the operational state of the power supply:
■ Off – PS is not connected to an AC power source.
■ Steady On – PS is connected to a properly rated AC power source.
System Module (SMOD) Indicators
The back panel indicators located on the SMOD allow you manage the server and determine
server status. The SMOD back panel indicator includes some indicators and buttons not
Troubleshooting and Diagnostics
65
Содержание X7-8
Страница 1: ...Oracle Server X7 8 Service Manual Part No E71936 01 October 2017 ...
Страница 2: ......
Страница 13: ...Contents Index 303 13 ...
Страница 14: ...14 Oracle Server X7 8 Service Manual October 2017 ...
Страница 16: ...16 Oracle Server X7 8 Service Manual October 2017 ...
Страница 46: ...46 Oracle Server X7 8 Service Manual October 2017 ...
Страница 268: ...268 Oracle Server X7 8 Service Manual October 2017 ...
Страница 294: ...294 Oracle Server X7 8 Service Manual October 2017 ...