Remove a Fan Module
Remove a Fan Module
Remove fan modules (FMs) to replace a failed FM, or to access CMODs.
1.
Prepare the server for service. Choose one of the following methods:
■
Prepare the server for hot service.
FMs are hot-service components.
Access CMODs behind the FMs using a hot-service procedure. See
■
Prepare the server for warm service.
Access CMODs behind the FMs using a warm-service procedure. See
■
Prepare the server for cold service.
Access CMODs behind the FMs using a cold-service procedure. See
“Preparing the Server for Component Replacement” on page 101
2.
Identify the fan module that requires removal by its position and designation.
Access fan modules (FMs) from the front of the server. A fan module in a failed state has a lit
steady on amber-color Fault-Service Required LED.
Servicing Components
131